Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"CLINAC"”.
-
"Dosimetric Properties of Clinac Electron Beam Depth Doses: An Investigation of Electron Beam ""Golden"" Data Set"
Made available in DSpace on 2017-07-06T18:55:55Z (GMT). No. of bitstreams: 2 Qayyum_Muqeem_A_MS.pdf: 3223744 bytes, checksum: a4b1aa0ed198965f4f43c8882d87d2ec (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) Previous issue date: 2006
-
Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data
… to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose …
-
Radiation Therapy and Dosing Material Transport Methodology
… used for external beam therapy, the Varian Clinac 2200C. Neutron output from the Clinac was modeled based on photonuclear production in the accelerator components when operated at 20MeV. Dose outputs were found to be viable for clinical use when the system is used on a Clinac due to the …
-
Small field dose measurements with Gafchromic film
… The output factors were measured from a Varian Clinac iX, Clinac 21EX, Trilogy, and TrueBeam; as well as a Novalis Tx. The outputs from different machines at different clinics were compared. Results: The EBT3 film and Edge Detector were the only detectors that succeeded in accurately measuring …
-
Strahlentherapie zur Schmerzbehandlung degenerativer Gelenkerkrankungen beim Hund: subjektive und objektive Evaluation der Wirksamkeit
… und an einem Linearbeschleuniger (Varian iX Clinac) mit Elektronen oder Photonen bestrahlt. Das Bestrahlungsprotokoll sah eine Dosis von 3x2Gy vor. Zwei Tierärzte evaluierten während 7 Monaten mit Hilfe des modifizierten VAMI und VAS den Schmerzstatus. Gleichzeitig wurden Ganganalysen mit dem …
-
Measurement and Monte Carlo simulation of electron fields for modulated electron radiation therapy
… produced by an older Varian accelerator, the Clinac 21EX. Differences in depth and profile characteristics of fields produced by the TrueBeam and those produced by the Clianc 21EX were found to be within 3%/3 mm. Given this information, complete accelerator models of the Clinac 21EX, based on …
-
Influência de blindagens de sala de radioterapia na dose efetiva de pacientes submetidos ao tratamento de câncer de próstata
… out by computationally simulating a Varian Clinac 2300/CD accelerator (15 MV), a radiotherapy room and an anthropomorphic phantom in voxels. The simulation of the linear accelerator was carried out based on the information of documents provided by the manufacturer Varian and validated, …
-
A coarse mesh transport method with novel source treatment
… of a 6 MV photon beam from a Varian c-series clinac. Of note is the use of a hemispherical harmonic expansion with the functional expansion tally method to model photonic fluence. The source was implemented in the COMET-PE radiation transport code and calculations performed with various field …
-
Bild-geführte hochpräzise Radiotherapie in der Behandlung von soliden Tumoren
… präsentiert: Novalis, TomoTherapy, Cybernife, Clinac, Trilogy, TrueBeam, Synergy, Leksell GammKnife, sowie Intrabeam, und viele andere. Seitens der Software, Algorithmen und Rechenleistung sind die Entwicklungen ebenfalls ohne historischen Vergleich. Diese explizit radiotherapeutischen Optionen …
-
Absolute Dose Verification in Intensity Modulated Radiation Fields
… All measurements were obtained using a Varian Clinac 21000 Varian Medical Systems Inc., Palo Alto, CA. The dosimetric property of Kodak XV film was verified for 6 and 18 MV photon beams. A technique to quantify film over response to low photon energy was presented. Monte Carlo calculations were …
-
A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices
… method is implemented for a Varian Clinac equipped with a 40 cm x 30 cm (512 x 384 pixel) EPID and a Pinnacle<sup>3</sup> TPS and tested for several rectangular and IMRT fields. The scatter, glare and energy-response correction kernel is implemented and tested for a simulated …
-
Insights into the radiation Chemistry of FLASH Radiation Therapy
… were performed using a modified Varian Clinac 21X. Spin adducts (•DMPO-OH, •DMPO-H) were quantified via electron paramagnetic resonance (EPR) spectroscopy 120 s post-irradiation. Analytical correction for decay kinetics was applied to estimate initial •OH and •H yields. Results: The BC …
-
Quality Assurance Procedures Implementation for Varian TrueBeam
… its linear accelerator (LINAC) from Varian Clinac iX to a newer model known as Varian TrueBeam. The Varian TrueBeam LINAC includes 6x, 6xFFF (i.e., 6x without flattening filter known as flattening filter free), 10x, 10xFFF, 15x photon beams and 6e, 9e, 12e MeV electron beams. This system is …
-
Computational and Experimental Investigation of the Shielding Properties of Polymer Composites for Space Applications
Reduction of dose to personnel and equipment in space is a matter of grave concern. Hydrogen rich materials, especially polymers such as polyethylene can provide substantial dose reduction. The inclusion of fillers in a polymer matrix can enhance the structural properties of the polymer, conserving …
-
Κατανομή δόσης από φωτόνια υψηλής ενέργειας σε υλικό μικρού ατομικού αριθμού κοντά σε ανομοιογένειες
… MV X-rays from a linear accelerator, the Varian Clinac DHX at the University General Hospital of Ioannina. Radiochromic films HD-810, MD-55 and ΕΒΤ3 were used for the experimental dose measurements. A flatbed scanner Microtek ScanMaker S480 was used for film scanning and digitization in the …