Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 55 for “"CMRR"”.

  1. A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition

    … to have very good Common Mode Rejection Ratio (CMRR) to amplify the weak biopotential while rejecting the stronger common mode interferers. Opamp based INAs with a resistor-capacitor feedback are suitable for acquiring biopotentials with low power and low noise performance. However, CMRR of such …

    tamu Repository record for A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition (opens in a new tab)

  2. Factors predictive of roof instability in addition to the existing CMRR criteria at two case study coal mines

    … coal mines is the Coal Mine Roof Rating (CMRR). The CMRR is a field-based empirical method which is straightforward to use and gives a quantitative interpretation of coal mine roof geology. The CMRR classification system was developed by Molinda and Mark (1994) to quantify the geological …

    colo-mines Repository record for Factors predictive of roof instability in addition to the existing CMRR criteria at two case study coal mines (opens in a new tab)

  3. A geostatistical calculation of the Coal Mine Roof Rating

    … which calculates a Coal Mine Roof Rating (CMRR) over a spatial area is established. In response to this need, a program which enables for the geostatistical calculation of the CMRR over a spatial area was developed as an engineering tool to quantify the geo-mechanical stability of the roof …

    wvu Repository record for A geostatistical calculation of the Coal Mine Roof Rating (opens in a new tab)

  4. Novel approaches in current-feedback operational amplifier design

    … (CFOA) with a good Common-Mode Rejection Ratio (CMRR), suitable for radio frequency (RF) applications. This research focused on investigation of the established CFOA with the emphases of improving CMRR, bandwidth, Voltage-Offset and Slew-rate performance. The majority of the results of this work …

    oxford-brookes Repository record for Novel approaches in current-feedback operational amplifier design (opens in a new tab) Download PDF for Novel approaches in current-feedback operational amplifier design (opens in a new tab)

  5. An Area-Based Calculation of the Analysis of Roof Bolt Systems (ARBS)

    … more detailed/accurate stress, varying CMRR and intersection span inputs. This tool imports the overburden, abutment and multiple-seam stresses as obtained by the boundary-element program LaModel and is converts them to a "pseudo-depth" which is used as the depth input to the ARBS …

    wvu Repository record for An Area-Based Calculation of the Analysis of Roof Bolt Systems (ARBS) (opens in a new tab)

  6. Optimizing secondary tailgate support selection

    … a stable tailgate entry during mining and the CMRR (Coal Mine Roof Rating). This relationship defines the lower bound of secondary support density currently used in longwall mines. The model used only successful tailgate case history data with adequate ALPS SF according to the CMRR for each …

    vt Repository record for Optimizing secondary tailgate support selection (opens in a new tab)

  7. Wideband active MMIC baluns -concepts and design

    … output with a common mode rejection ratio (CMRR) above 22 dB. The second concept combines three differential pairs, resulting in a CMRR of above 26.5 dB. The third concept consists of two parallel connected distributed amplifiers that create a matrix balun with a CMRR of above 22 dB. The …

    chalmers Repository record for Wideband active MMIC baluns -concepts and design (opens in a new tab)

  8. A Low Power 8 to 1 Analog Multiplexer for Bio-Signal Acquisition System with a Function of Amplification

    … amplifier with low power consumption, high CMRR, and high gain is connected to the output port of the multiplexer. In this way, the bio-signals can be easily detected and selected. For the analog multiplexer design, a parallel transmission gate structure is used to select the desired signal …

    carleton Repository record for A Low Power 8 to 1 Analog Multiplexer for Bio-Signal Acquisition System with a Function of Amplification (opens in a new tab)

  9. Low Power Circuits for Smart Flexible ECG Sensors

    … stage increases the input impedance and improves CMRR. A parasitic capacitor reuse technique is proposed to improve the noise/area efficiency and CMRR. An on-body DC bias scheme is introduced to deal with the input DC offset. Implemented in 0.35m CMOS process with an area of 0.405mm2, the proposed …

    york Repository record for Low Power Circuits for Smart Flexible ECG Sensors (opens in a new tab)

  10. A Current Balancing Instrumentation Amplifier (CBIA) Bioamplifier with High Gain Accuracy

    … corner frequency, high common mode rejection (CMRR) and low noise efficiency factor (NEF). The proposed circuit has been implemented in the 0.5um CMOS ON-semiconductor process and consumes 16uW of power. The post-layout simulated gain accuracy is better than 94% for gain values from 20dB to …

    tamu Repository record for A Current Balancing Instrumentation Amplifier (CBIA) Bioamplifier with High Gain Accuracy (opens in a new tab)

  11. Incorporação de dados geomecânicos em projetos de suporte de teto em mina subterrânea de carvão

    … de acordo com o sistema Coal Mine Roof Rating (CMRR) proposto pelo U.S. Bureauof Minesem 1994. Diferentes índices de CMRRforam identificados e então considerados para definir a largura máxima nos cruzamentos, o comprimentoe a capacidadede carregamento dos parafusos de teto. Estatísticas da mina …

    brazil-ufrgs Repository record for Incorporação de dados geomecânicos em projetos de suporte de teto em mina subterrânea de carvão (opens in a new tab)

  12. Determination of Bioimpedance Using Multi-Frequency Bio-electrical Impedance Analysis

    … gain operational amplifier with high CMRR is designed to develop current sources, voltage measuring circuits and post-processing circuits. Transient and DC simulations have been done to validate the concept of determination of bioimpedance. Layouts have been designed and the chip is …

    carleton Repository record for Determination of Bioimpedance Using Multi-Frequency Bio-electrical Impedance Analysis (opens in a new tab)

  13. Unconventional support assessment for mines in sedimentary bedrock - Applicability of rock classification systems in horizontally bedded sandstone

    … the applicability of Coal Mine Roof Rating, CMRR, in other settings. The assessment of the classification system is performed through a comparison to Rock Mass Rating, RMR. Both systems are evaluated through a case study of the Kvarntorp mine, a sedimentary sandstone mine in Sweden. The mine …

    chalmers Repository record for Unconventional support assessment for mines in sedimentary bedrock - Applicability of rock classification systems in horizontally bedded sandstone (opens in a new tab)

  14. Geomechanical behaviour and deformation of coal mine roof strata around faults: toward an engineering geological model

    … rock mass rating (RMR), coal mine roof rating (CMRR), roof strength index (RSI) and the Q-system. Both the Leichhardt Seam and overburden rock show marked spatial variability in terms of RMR, CMRR and Q, but RSI showed limited sensitivity to changes in rock mass condition. Relationships were …

    unsw Repository record for Geomechanical behaviour and deformation of coal mine roof strata around faults: toward an engineering geological model (opens in a new tab)

  15. LOW POWER AND HIGH SIGNAL TO NOISE RATIO BIO-MEDICAL AFE DESIGN TECHNIQUES

    … will have a better Common Mode rejection ratio (CMRR). The main function of the AFE is to convert the weak electrical Signal into large signals whose amplitude is large enough for an Analog Digital Converter (ADC) to detect without having any errors. A Variable Gain Amplifier (VGA) is sometimes …

    oxford-brookes Repository record for LOW POWER AND HIGH SIGNAL TO NOISE RATIO BIO-MEDICAL AFE DESIGN TECHNIQUES (opens in a new tab) Download PDF for LOW POWER AND HIGH SIGNAL TO NOISE RATIO BIO-MEDICAL AFE DESIGN TECHNIQUES (opens in a new tab)

  16. Subwavelength Gratings Engineered 90 degree Optical Hybrid Component for Coherent Detection

    … is 59.5 um. Both devices offer minimal loss, a CMRR over -20 dB, phase deviation within ±2°, and imbalance below ±1 dB across the 1.45 um–1.65 um range. The parabolic design reduces device length by 20.24%, and the linear by 14.32%, compared to rectangular MMI designs.

    carleton Repository record for Subwavelength Gratings Engineered 90 degree Optical Hybrid Component for Coherent Detection (opens in a new tab)

  17. NEURAL RECORDING INTEGRATED CIRCUITS

    … OF THIS WORK ADDRESSES THE PROBLEM OF LIMITED CMRR OF MULTI-CHANNEL NEURAL AMPLIFIER SYSTEMS BY PROPOSING A NEURAL AMPLIFIER SYSTEM THAT HAS BALANCED INPUT IMPEDANCE AMONGST ALL THE INPUT AND REFERENCE CHANNELS. DEDICATED CMOS-INVERTER-BASED FRONT AMPLIFIERS ARE USED FOR BOTH THE REFERENCE AND …

    nus Repository record for NEURAL RECORDING INTEGRATED CIRCUITS (opens in a new tab) Download file for NEURAL RECORDING INTEGRATED CIRCUITS (opens in a new tab)

  18. A MULTI-CHANNEL ECG RECORDING SYSTEM WITH FDM TECHNIQUE FOR 12-LEAD APPLICATIONS

    … s down to only 0.6 s. The MCIA achieves 112.5-dB CMRR, 113.0-dB PSRR, and 1.44-μVrms noise performance. The MCIA occupies only 0.3 mm2 and consumes 60μW for 8 channels. The whole ECG recording system was implemented in 130-nm CMOS technology.

    nus Repository record for A MULTI-CHANNEL ECG RECORDING SYSTEM WITH FDM TECHNIQUE FOR 12-LEAD APPLICATIONS (opens in a new tab) Download file for A MULTI-CHANNEL ECG RECORDING SYSTEM WITH FDM TECHNIQUE FOR 12-LEAD APPLICATIONS (opens in a new tab)

  19. Generalized impedance converter (GIC) filter utilizing composite amplifier

    … product (GBWP), common mode rejection ratio (CMRR), and open loop gain are considerably improved. This sets the basic foundation for future students to incorporate the newly designed composite operational amplifier into the GIC filter to further enhance filter performance.

    nps Repository record for Generalized impedance converter (GIC) filter utilizing composite amplifier (opens in a new tab)

  20. Design of a High Performance Silicon Carbide CMOS Operational Amplifier

    … bandwidth (around 5 MHz) and maintain a high CMRR and PSRR within a useful input common mode range over process corners and a wide temperature range (25 °C - 300 °C). Between the two stages a Miller compensation topology is placed to improve the phase margin (around 45°). Due to the …

    arkansas Repository record for Design of a High Performance Silicon Carbide CMOS Operational Amplifier (opens in a new tab)

Page 1 of 3