Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"CMUT Arrays"”.

  1. Acoustic forces and microparticles manipulation using CMUT arrays

    … creating a patterned pressure field, by using a CMUT (Capacitive Micromachined Ultrasonic Transducer) array to manipulate microparticles in two-dimensional space. CMUTs are MEMS-based ultrasound transducers, that can generate and receive ultrasound signals. By digitally controlling the amplitude …

    ubc Repository record for Acoustic forces and microparticles manipulation using CMUT arrays (opens in a new tab) Download PDF for Acoustic forces and microparticles manipulation using CMUT arrays (opens in a new tab)

  2. Investigation of acoustic crosstalk effects in CMUT arrays

    Capacitive Micromachined Ultrasonic Transducers (CMUTs) have demonstrated significant potential to advance the state of medical ultrasound imaging beyond the capabilities of the currently employed piezoelectric technology. Because they rely on well-established micro-fabrication techniques, they can …

    gatech Repository record for Investigation of acoustic crosstalk effects in CMUT arrays (opens in a new tab)

  3. Integrated Electronics for Wireless Imaging Microsystems with CMUT Arrays

    Integration of transducer arrays with interface electronics in the form of single-chip CMUT-on-CMOS has emerged into the field of medical ultrasound imaging and is transforming this field. It has already been used in several commercial products such as handheld full-body imagers and it is being …

    gatech Repository record for Integrated Electronics for Wireless Imaging Microsystems with CMUT Arrays (opens in a new tab)

  4. CMUT array design and fabrication for high frequency ultrasound imaging

    … Capacitive micromachined ultrasonic transducers (CMUTs) possess multiple preferable characteristics for high frequency imaging systems, such as simpler fabrication methods, simpler integration to electronics, and greater variety of array geometries. Adequate performance and optimization of CMUT …

    gatech Repository record for CMUT array design and fabrication for high frequency ultrasound imaging (opens in a new tab)

  5. Flexible polymer-based capacitive micromachined ultrasonic transducers (polyCMUTs) for conformal sonography

    … to their rigid construction. Flexible ultrasound arrays could better conform to patient anatomy, potentially improving acoustic coupling, and provide larger field of view with a single acquisition event. However, their performance under bending and varying shape during use pose new challenges. …

    ubc Repository record for Flexible polymer-based capacitive micromachined ultrasonic transducers (polyCMUTs) for conformal sonography (opens in a new tab) Download PDF for Flexible polymer-based capacitive micromachined ultrasonic transducers (polyCMUTs) for conformal sonography (opens in a new tab)

  6. Fabrication technology and design for CMUTS on CMOS for IVUS catheters

    … capacitive micromachined ultrasonic transducer (CMUT) arrays for intravascular ultrasonic (IVUS) imaging along with the fabrication processes to allow for monolithic integration of CMUTs with custom CMOS electronics for improved performance. The IVUS imaging arrays include dual-ring arrays for …

    gatech Repository record for Fabrication technology and design for CMUTS on CMOS for IVUS catheters (opens in a new tab)

  7. Capacitive micromachined ultrasound transducer (CMUT) design and fabrication for intracardiac echocardiography

    … capacitive micromachined ultrasonic transducer (CMUT) arrays with novel geometry for intracardiac echocardiography (ICE) imaging along with a novel reliable CMUT fabrication process to improve the system performance. We used custom CMOS electronics and monolithically integrated our CMUT arrays to …

    gatech Repository record for Capacitive micromachined ultrasound transducer (CMUT) design and fabrication for intracardiac echocardiography (opens in a new tab)

  8. Material and array design for CMUT based volumetric intravascular and intracardiac ultrasound imaging

    … capacitive micromachined ultrasonic transducers (CMUT) based imaging catheters for intravascular ultrasound (IVUS) and intra-cardiac echocardiography (ICE) for 3-D volumetric imaging through integration of high-k thin film material into the CMUT fabrication and array design. CMUT-on-CMOS …

    gatech Repository record for Material and array design for CMUT based volumetric intravascular and intracardiac ultrasound imaging (opens in a new tab)

  9. A PolyMUMPs Capacitive Micromachined Ultrasonic Transducer

    … Capacitive Micromachined Ultrasonic Transducers (CMUTs) with one and multiple bottom electrodes and their fabrication using the PolyMUMPs technique provided by MEMSCAP Inc. It also reports a new behavioral model of the CMUTs written in VHDL-AMS, complemented by a comparison between finite element …

    ubc Repository record for A PolyMUMPs Capacitive Micromachined Ultrasonic Transducer (opens in a new tab) Download PDF for A PolyMUMPs Capacitive Micromachined Ultrasonic Transducer (opens in a new tab)

  10. Development of an ultrasound sleeve for real-time diagnosis of fracture in the lower limb

    … Capacitive Micromachined Ultrasonic Transducer (CMUT)-based ultrasound sleeve developed in this study aims to address these constraints by offering real-time fracture detection with enhanced sensitivity and portability. This research investigates whether CMUT arrays, coupled with real-time …

    vu-aus Download PDF for Development of an ultrasound sleeve for real-time diagnosis of fracture in the lower limb (opens in a new tab) Embargoed until 2027-09-08

  11. Modeling and optimization of capacitive micromachined ultrasonic transducers

    … Capacitive Micromachined Ultrasonic Transducers (CMUTs), especially when they are used in an array configuration. General modeling and optimization methods that cover a large domain of CMUT designs are crucial, as many membrane and array geometry combinations are possible using existing …

    gatech Repository record for Modeling and optimization of capacitive micromachined ultrasonic transducers (opens in a new tab)

  12. The Design, Fabrication and Characterization of Capacitive Micromachined Ultrasonic Transducers for Imaging Applications

    Capacitive micromachined ultrasonic transducers (CMUTs) have proven themselves to be excellent candidates for medical ultrasonic imaging applications. The use of semiconductor fabrication techniques facilitates the fabrication of high quality arrays of uniform cells and elements, broad acoustic …

    waterloo Repository record for The Design, Fabrication and Characterization of Capacitive Micromachined Ultrasonic Transducers for Imaging Applications (opens in a new tab)

  13. Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging

    … Capacitive micromachined ultrasonic transducer (CMUT) technology was chosen to fabricate the array as it offers micro-precision fabrication and a wide bandwidth, which make it an attractive transducer technology. The objective of this thesis is to investigate and demonstrate the imaging potential …

    waterloo Repository record for Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging (opens in a new tab)

  14. Ultrasonic subwavelength acoustic focusing and imaging using a 2D membrane metamaterial

    … Micromachined Ultrasonic Transducers (CMUT) as a specific example. CMUT arrays can generate and detect membrane displacement capacitively, and are shown to support the surface waves capable of subwavelength focusing and imaging. A model is developed that can solve for the modes of the …

    gatech Repository record for Ultrasonic subwavelength acoustic focusing and imaging using a 2D membrane metamaterial (opens in a new tab)

  15. Advanced Devices for Photoacoustic Imaging to Improve Cancer and Cerebrovascular Medicine

    … these treatments. However, clinical ultrasound arrays are not clinically feasible for microsurgical applications due to their bulky size and linear scanning requirements for 3D. Therefore, capacitive micromachined ultrasound transducer (CMUT) two-dimensional arrays compatible with standard …

    arizona-thes Repository record for Advanced Devices for Photoacoustic Imaging to Improve Cancer and Cerebrovascular Medicine (opens in a new tab)