Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 42 for “"CMUTs"”.
-
A novel fabrication process for CMUTs in air
… capacitive micromachined ultrasonic transducers (CMUTs) is presented. The process uses conductive silicon on insulator (SOI) substrates to produce an unstressed transducer diaphragm. By etching release holes through the device layer and selectively removing the underlying buffered oxide (BOX) …
-
Capacitive Micromachined Ultrasonic Transducers (CMUTs) for Humidity Sensing
… capacitive micromachined ultrasonic transducers (CMUTs) have proven themselves to be promising for various ultrasound imaging and chemical sensing applications. Although holding many benefits for ultrasound imaging, CMUTs have certain weaknesses such as the relatively low output pressure at …
-
Exploring multiple-mode vibrations of capacitive micromachined ultrasonic transducers (CMUTs)
Capacitive Micromachined Ultrasonic Transducers (CMUTs) are considered advantageous over piezoelectric transducers for ultrasound imaging for the high bandwidth, ease of integration with electronics and miniaturization. Research efforts over the past two decades have been focusing on manufacturing …
-
Fabrication technology and design for CMUTS on CMOS for IVUS catheters
… processes to allow for monolithic integration of CMUTs with custom CMOS electronics for improved performance. The IVUS imaging arrays include dual-ring arrays for forward-looking volumetric imaging in coronary arteries and annular-ring arrays with dynamic focusing capabilities for side-looking …
-
Advancing sensitivity and performance of Capacitive Micromachined Ultrasound Transducers (CMUTs) for medical imaging
… Capacitive Micromachined Ultrasound Transducers (CMUTs) use electrostatic transduction to generate and detect sound waves, promise broader bandwidth, smaller size, and better integration with electronics than piezoelectric transducers, which improves Transduction efficiency and frequency response …
-
Nonlinear Dynamics of Circular Plates under Electrical Loadings for Capacitive Micromachined Ultrasonic Transducers (CMUTs)
… capacitive micromachined ultrasonic transducers (CMUTs). After establishing the equations governing the plate, we discretized the system by using a Galerkin approach. The distributed-parameter equations were then reduced to a finite system of ordinary-differential equations in time. We solved …
-
Design and evaluation of CMUTs for medical ultrasound imaging with a focus on non-invasive blood pressure waveform monitoring
… capacitive micromachined ultrasonic transducers (CMUTs). The work combines: (i) a critical review of ultrasonic BP-waveform sensing; (ii) experimental analysis of CMUT topology, quality factor, and damping; and (iii) the development of a hybrid CMUT fabrication process that integrates printed …
-
Capacitive Micromachined Ultrasonic Transducers for Non-destructive Testing Applications
… capacitive micromachined ultrasonic transducers (CMUTs) have become popular in medical ultrasound research because of their large bandwidths and other attributes that allow them to be integrated into the tip of a catheter. However, CMUTs have not been widely adopted in ultrasonic NDT applications. …
-
Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer
… capacitive Micromachined Ultrasonic Transducers (cMUTs) emerge as an alternative choice to traditional PZT ceramic based transducers in ultrasonic imaging. They not only have better bandwidth and sensitivity in producing better imaging resolution, low signal-to-noise ratio, but they allow the …
-
Dual-electrode capacitive micromachined ultrasonic transducers for medical ultrasound applications
Capacitive Micromachined Ultrasonic Transducers (CMUTs) have been introduced as a viable alternative to piezoelectric transducers in medical ultrasound imaging in the last decade. CMUTs are especially suitable for applications requiring small size such as catheter based cardiovascular applications. …
-
Capacitive Micromachined Ultrasonic Transducers: Design, Fabrication and Characterization
Capacitive micromachined ultrasonic transducers (CMUTs) have been developed as an alternative to piezoelectric transducers for ultrasonic imaging in non-destructive testing applications. These CMUTs offer substantial advantages over their piezoelectric counterparts, which include a highly …
-
Modeling and optimization of capacitive micromachined ultrasonic transducers
… Capacitive Micromachined Ultrasonic Transducers (CMUTs), especially when they are used in an array configuration. General modeling and optimization methods that cover a large domain of CMUT designs are crucial, as many membrane and array geometry combinations are possible using existing …
-
Design and analysis of capacitive micromachined ultrasound transducer
Capacitive Micromachined Ultrasound Transducers (CMUTs) have been recently introduced as a viable substitute to piezoelectric transducers in medical ultrasound imaging. CMUT possesses advantages such as allowing high frequency, having wide bandwidth, high sensitivity, low cost, CMOS compatibility …
-
A Feasibility Study of Micromachined Ultrasonic Transducers Functionalized for Ethanol Dectection
… Capacitive Micromachined Ultrasonic Transducers (CMUTs) and Piezoelectric Micromachined Ultrasonic Transducer (PMUTs), which both work based on the mass-loading effect, are considered as the promising types of MEMS sensors for gas sensing. Since they are fabricated in a batch manner with the …
-
Acoustic Simulation and Characterization of Capacitive Micromachined Ultrasonic Transducers (CMUT)
… fundamentals for the future commercialization of CMUTs. It introduces novel methods for the acoustic simulation and characterization of CMUTs, which are still critical steps in the product development process. They allow an easy CMUT cell design for given application requirements. Based on a novel …
-
Simulation of a Capacitive Micromachined Ultrasonic Transducer with a Parylene Membrane and Graphene Electrodes
… Capacitive Micromachined Ultrasonic Transducers (CMUTs) appears as an alternative to the piezoelectric (PZT) ceramic based transducer for ultrasound medical imaging. CMUTs show better ultrasound transducer design for batch fabrication, higher axial resolution of images, lower fabrication costs of …
-
Air-coupled Capacitive Micromachined Ultrasonic Transducers based on Annular Cell Geometry
… Capacitive Micromachined Ultrasonic Transducers (CMUTs), can be fabricated through silicon micromachining processes in a low cost manner. Given the thin plates, a CMUT is able to vibrate with a low mechanical impedance and thus a high coupling efficiency with the ambient atmosphere. Nevertheless, …
-
Fabrication of Capacitive Micromachined Ultrasonic Transducers based on Adhesive Wafer Bonding
Capacitive micromachined ultrasonic transducers (CMUTs) can be used for medical imaging, non-destructive testing or medical treatment applications. It can also be used as gravimetric sensors for gas sensing or immersion bio-sensing. Although various CMUT fabrication methods have been reported, …
-
Interdigital Capacitive Micromachined Ultrasonic Transducers for Microfluidic Applications
… capacitive micromachined ultrasonic transducers (cMUTs) were developed which generate guided acoustic waves in fluid half-spaces and microchannels. An interdigital transducer structure and a phased excitation scheme were used to selectively excite guided acoustic modes which propagate in a single …
-
Design, modeling and fabrication of polymer-based Capacitive Micromachined Ultrasonic Transducers (polyCMUTs)
… Capacitive Micromachined Ultrasonic Transducers (CMUTs) are considered the replacement of piezoelectric transducers given their high bandwidth, ease of integration with electronics and miniaturization. The main focus of this dissertation involves the simulation, fabrication and characterization of …
Page 1 of 3