Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 437 for “"COD removal."”
-
Kinetics of COD Removal in Combined Aerobic-Methanogenic Batch Reactors
… wastewater treatment capabilities by measuring COD and BOD removal rate, effluent quality and process stability.
-
Combination of Partial nitrification and inert COD removal processes in a membrane bioreactor to treat leachate in Vietnam
… 800 – 1,200 mgN.l-1 and chemical oxygen demand (COD) values ranging between 2,500 – 5,000 mg.l-1, with a substantial fraction composed of refractory organics. The persistence of these pollutants results in significant environmental risks, particularly when untreated or insufficiently treated …
-
Cod removal, nitrification and denitrification kinetics and mathematical modeling of an integrated fixed film activated sludge (IFAS) system
Biological nitrogen and phosphorus removal are being recommended at several wastewater treatment facilities in the U.S. to control eutrophication in water bodies receiving their effluent. In several instances, nitrogen removal is being recommended on a year round basis at plants located in the …
-
Influence of carrier surface area and surface area loading rate on moving bed biofilm reactor performance in COD removal from municipal and industrial wastewater
… However, the number of studies on substrate removal, especially at high loading rates, from municipal and industrial wastewater using these technologies is limited compared to the other conventional systems. Therefore, this study was conducted to evaluate the organic matter removal …
-
Treatment of oil-water emulsion from the machinery industry by Fenton's reagent
The chemical oxygen demand (COD) removal efficiency for treatment of an oil-water emulsion from the machinery industry using Fenton's reagent was investigated. The optimal [H 2 O 2 ]/[Fe 2+ ] molar ratio for COD removal was 3. An orthogonal test was designed based on the optimal molar [H 2 O 2 …
-
COD removal and nitrification of piggery wastewater in a sequencing batch reactor : a thesis submitted in partial fulfilment of the requirements for the degree of Master of Technology in Environmental Engineering
… contain high levels of chemical oxygen demand (COD) and also nutrients such as nitrogen and phosphorus which can cause eutrophication in surface waters. The sequencing batch reactor is a form of biological treatment in a completely mixed reactor with aerobic and anoxic periods to facilitate …
-
Treatment of dilute aircraft deicing fluid (ADP) using an anaerobic baffled reactor (ABR)
… different hydrological retention times (HRT) and COD influent concentrations. A total of 17 experimental runs were conducted in continuous mode, achieving COD removal efficiencies of over 75% for most of the conditions tested. During this experiment different ADF concentrations (0.04%, 0.07%, and …
-
Attached growth fungal system for corn wet milling wastewater treatment
… conditions enhanced the chemical oxygen demand (COD) removal and biomass yield from 50% and 0.11 g(dry-weight)/gCODremoved to 55% and 0.16 g(dry-weight)/gCODremoved, respectively. Under non-aseptic operation, total biomass production of 0.32 g volatile suspended solids (VSS)/gCOD removed was …
-
Practical applications of microbial fuel cell technology in winery wastewater treatment
… power production and chemical oxygen demand (COD) removal. When the reactor was maintained at 1000 mg/L COD, the highest COD removal rate was reached within 4 hours (h) and overall removal reached ~80% within 60 h, the maximum output voltage was obtained within 0.5 h and lasted for 60±3 h. A …
-
EVALUATING THE ANAEROBIC CODIGESTION POTENTIAL OF STILLAGE AND DAIRY MANURE IN A TUBULAR DIGESTER
… parameters were adjusted until the predicted COD removal was consistent with data obtained using two full-scale digesters. Simulations were performed to evaluate COD removal and biogas production for nine different mixtures of stillage and manure at four different temperatures ranging from …
-
Integrating membrane, ozonation, and biological processes for the treatment of alkaline bleach plant effluent
The removal of organic compounds from alkaline bleach plant pulp mill effluent was investigated using integration of ozonation, biological treatment, and ultrafiltration processes. The synergies of combining these processes were studied. O₃-Bio, Bio-O₃-Bio, and UF-(O₃-)r --(Bio)rf combined …
-
Avaliação das técnicas eletrolíticas de eletrocoagulação-eletroflotação e eletro-oxidação separadas e conjugadas aplicadas no tratamento de lixiviados
… osmosis concentrate) landfills; aiming the removal of chemical oxygen demand (COD). In initial assays electrocoagulation-electroflotation (ECF) with aluminum electrodes (Al) was applied in leachate treatment of BR/RJ 01 and BR/RJ 02 landfills, obtaining 50 to 64% of COD removal with best …
-
Selective disinfection for enhanced nonaseptic fungal production from food processing wastewater
… utilization in terms of chemical oxygen demand (COD) removal and led to larger population growths in the fungi. That is, a dosage of 60mg/L of hydrogen peroxide led to 85% COD removal and produced 1.8 g of dry fungal biomass from a liter of CPW; compared with the control, COD removal efficiency …
-
Evaluation of landfill leachate and waste dumping site soil treatment by using chemical and biological methods
… that ozonation of raw leachate achieved 16% COD removal after 240 min of treatment while O3 + H2O2 achieved 33% COD removal of raw leachate with 900 mg/L H2O2 in 120 min. Moreover, the COD removal from raw leachate was only 33% by using Fenton’s reagents. After biological stabilization, …
-
Design and Optimization of Membrane Filtration and Activated Carbon Processes for Industrial Wastewater Treatment Based on Advanced and Comprehensive Analytical Characterisation Methodologies
… the specific compounds that are the source of COD. During 10 months, about 75 industrial samples were characterized using a battery of tests including GC/MS, COD, TOC, and pH to identify the chemicals that are main source of COD in the industrial wastewaters. Results showed that the COD of 87% …
-
Estudos do tratamento de águas residuárias do café usando coagulação e processos de oxidação avançada
… pH, conductivity, Chemical Oxygen Demand (COD), and Total Organic Carbon (TOC). Due to high turbidity values (279.0 NTU) and COD (9067.0 mg L-1), it was adopted to always perform a coagulation pre-treatment using aluminum sulfate. This process removed about 97% of turbidity and 20% of COD …
-
Application of submerged membrane bioreactor for converting high strength wastewater into clean water
… high performance in organics and nutrients removal for a high strength industrial wastewater feed. During the 300 days of continuous operation, chemical oxygen demand (COD) values of the permeate fell to less than 10 mg-L-1 after just 100 days. This would represent an excellent organic …
-
Energy Recovery and Treatment of Brewery Wastewater in a Bioelectrochemically Enhanced Anaerobic Digestion System
… transition to brewery wastewater. Over 90% COD removal at all feeds demonstrated the system’s ability in handling simple and complex feeds such as brewery wastewater. Second, BEAD’s performance was evaluated on increasing organic loading rates (OLRs) from 1 to 7 g sCOD/L.d, achieving over …
Page 1 of 22