Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"COUNTERPULSATION DEVICE"”.
-
Feasibility of subcutaneous ECG leads for synchronized timing of a counterpulsation device.
Background: Emerging circulatory support devices that operate in counterpulsation to the native heart require synchronized timing of device ejection and filling on a beat-to-beat basis with the native heart using a patient's ECG. Surface leads are commonly used for short-term patient monitoring but …
-
Η επίδραση της παραορτικής αντλίας αντιώθησης (PULVAD) στη στεφανιαία ροή και στη ροή στις καρωτίδες σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας
… the Pressure Unloading Left Ventricular Assist Device (PULVAD), a novel implantable counterpulsation device, designed to provide left ventricular (LV) pressure unloading with augmentation of LV performance and retention of pulsatility. Methods: Seven farm pigs (75-95 kg) underwent PULVAD …
-
Η επίδραση της υποβοήθησης με παραορτική αντλία αντιώθησης (PULVAD) στους δείκτες συστολικής και διαστολικής λειτουργίας της αριστεράς κοιλίας σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας
… the Pressure Unloading Left Ventricular Assist Device (PULVAD), a novel implantable counterpulsation device, designed to provide left ventricular (LV) pressure unloading with augmentation of LV performance and retention of pulsatility. We assessed the effects of PULVAD on hemodynamics, LV …
-
Cardiac Output Improvement in Mechanical Circulatory Support Devices
Mechanical circulatory support devices (MCSDs) have gained widespread clinical acceptance as an effective heart failure (HF) therapy. The concept of harnessing the kinetic energy (KE) available in the forward aortic flow (AOF) is proposed as a novel control strategy to further increase the cardiac …
-
Μηχανική υποβοήθηση ανεπαρκούσης καρδίας με τη τεχνική της αντιώθησης: πειραματική μελέτη
… and wide availability, is the most often used device for this purpose. The Paraaortic Counterpulsation Device (PACD) with 100ml stroke volume, has been proven superior to the IABP and has been proposed as an alternative in cases of profound hemodynamic decompensation, when the IABP is …
-
Counterpulsation cardiac assist device controller defection filter simulation and canine experiments
Electronic control systems for counterpulsation Cardiac Assist Devices (CADs) are an essential part of cardiac assistance. Synchronization of the counterpulsation CAD controller with the cardiac cycle is critical to the efficacy of the CAD. The robustness of counterpulsation CAD controllers varies …
-
ΑΙΜΟΔΥΝΑΜΙΚΗ ΕΠΙΔΡΑΣΗ ΤΗΣ ΠΑΡΑ-ΑΟΡΤΙΚΗΣ ΑΝΤΛΙΑΣ ΑΝΤΙΩΘΗΣΕΩΣ, ΕΜΦΥΤΕΥΘΕΙΣΑΣ ΣΤΗΝ ΑΝΙΟΥΣΑ ΑΟΡΤΗ ΣΕ ΔΥΟ ΔΙΑΔΟΧΙΚΑ ΣΤΑΔΙΑ ΟΞΕΙΑΣ ΠΕΙΡΑΜΑΤΙΚΗΣ ΚΑΡΔΙΑΚΗΣ ΑΝΕΠΑΡΚΕΙΑΣ
THE PARA-AORTIC COUNTER PULSATION DEVICE (PACD) IS SPHEROID WITH A SINGLE VALVELESS ORIFICE AND IT HAS 100 ML STROKE VOLUME. IN THIS STUDY WE EVALUATED THE HEMODYNAMIC EFFECTS OF THE PACD, IMPLANTED ON THE ASCENDING AORTA IN GRADED ACUTE EXPERIMENTAL HEART FAILURE. IN 18 EXPERIMENTAL ANIMALS THE …