Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"CPU Cooling"”.

  1. The effects of carbon nanotubes on cpu cooling

    Computers today have evolved from being big bulky machines that took up rooms of space into small simple machines for net browsing and into small but complicated multi-core servers and supercomputing architectures. This has been possible due to the evolution of the processors. Today processors have …

    utc Repository record for The effects of carbon nanotubes on cpu cooling (opens in a new tab)

  2. A Thermally Driven Two-Phase Cooling Device for CPU Cooling

    … the present study developed a novel cooling solution with essential attributes of compactness, low-cost, high cooling capacity, low power consumption, and orientation-free design. To achieve these, the mechanism of phase change was utilized. Fundamental boiling experiments were …

    nus Repository record for A Thermally Driven Two-Phase Cooling Device for CPU Cooling (opens in a new tab) Download file for A Thermally Driven Two-Phase Cooling Device for CPU Cooling (opens in a new tab)

  3. CPU Cooling in Data Center Using a Thermosiphon Loop with Tapered Open Microchannel Manifold (OMM)

    The efficient cooling of servers in data center offers a unique challenge to reduce the worldwide energy consumption and liquid inventory of working fluid. Presently, single phase cooling techniques are widely used for CPU cooling in data centers. Such techniques are proving to be inefficient, as …

    rit Repository record for CPU Cooling in Data Center Using a Thermosiphon Loop with Tapered Open Microchannel Manifold (OMM) (opens in a new tab)

  4. High Heat Flux Dissipation Using Innovative Dual Tapered Manifold in Pool Boiling, and Thermosiphon Loop for CPU Cooling in Data Centers

    … of processors. The high heat fluxes in CPUs are affecting the reliability and processing ability of the servers. Due to these thermal limitations, large amount of energy is required to cool the servers in data centers. The advanced two-phase boiling heat transfer systems are …

    rit Repository record for High Heat Flux Dissipation Using Innovative Dual Tapered Manifold in Pool Boiling, and Thermosiphon Loop for CPU Cooling in Data Centers (opens in a new tab)

  5. Exploiting Physical Side-Channel Information for Offensive and Defensive Ends

    … attack vector named FanBleed that exploits the CPU cooling fan's mechanical movements to infer sensitive information about ongoing computational activities. We demonstrate the real-world impacts of FanBleed through two attacks: a website fingerprinting attack and a cryptanalytic attack targeting …

    clemson Repository record for Exploiting Physical Side-Channel Information for Offensive and Defensive Ends (opens in a new tab)

  6. Assessment of AI Tools for CFD Acceleration and Generalization

    … work, namely a mixing elbow flow problem and a CPU cooling problem involving conjugate heat transfer. The main objective of the work is to evaluate the prediction accuracy, generalization capability, computational efficiency, and practical applicability of AI based surrogate models for …

    chalmers Repository record for Assessment of AI Tools for CFD Acceleration and Generalization (opens in a new tab)

  7. The Effects of Agitation on convective heat transfer with applications to electronics cooling

    … number of chips and smaller and smaller CPU sizes, heat fluxes that need to be dissipated from computers are on a rapid increase. CPU cooling being critical to the performance of electronic devices, this field demands considerable research focus. Researchers have been pushing existing …

    umn Repository record for The Effects of Agitation on convective heat transfer with applications to electronics cooling (opens in a new tab)

  8. Experimental Simulation of Nucleating Bubble Behavior in a Microgap with Air Injected Bubbles

    The following study investigates the behavior of bubbles created by air injection under a tapered microgap. It is a continuation of previous work from the Thermal Analysis and Microfluidics Lab at RIT which showed that placing a tapered gap manifold over a heated surface in a pool boiling setup …

    rit Repository record for Experimental Simulation of Nucleating Bubble Behavior in a Microgap with Air Injected Bubbles (opens in a new tab)

  9. A novel linear electromagnetic-drive oil-free refrigeration compressor

    <p>There is a need to improve the capabilities of cooling technology to dissipate increasingly high heat fluxes (approaching 200 W/cm<sup>2</sup>) from electronic components in order to maintain acceptable operating temperatures. The linear compressor with clearance seal and flexure spring which …

    oxford Restricted access

  10. INFLUENCE OF MICRO-NUCLEATE BOILING ON ANNULAR FLOW REGIME HEAT TRANSFER COEFFICIENT VALUES AND FLOW PARAMETERS – FOR HIGH HEAT-FLUX FLOW BOILING OF WATER

    Analysis of results from steady and steady-in-the-mean high heat-flux (15 - 70 W/cm2, with water as working fluid) shear driven annular flow-boiling experiments presented here - and low heat-flux (0.1- 1 W/cm2, with FC-72 as working fluid) experiments presented elsewhere – together lead to a key …

    mtu Repository record for INFLUENCE OF MICRO-NUCLEATE BOILING ON ANNULAR FLOW REGIME HEAT TRANSFER COEFFICIENT VALUES AND FLOW PARAMETERS – FOR HIGH HEAT-FLUX FLOW BOILING OF WATER (opens in a new tab)