Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 293 for “"CRYOSTAT"”.
-
Cryostat System for Spacecraft Materials Testing
… incorporating a two-stage, closed-cycle helium cryostat, it is now possible to simulate the temperature typical spacecraft will experience when in orbit, ranging from < 40 K to > 450 K. The system was designed to maintain compatibility with an existing ultrahigh vacuum chamber that can simulate …
-
The EBEX cryostat and supporting electronics.
… to predictions. The temperatures of the cryostat were stable. An analysis of the temperature data finds no scan synchronous signal in the cryostat temperatures. The timing system and pressure vessels operated as expected. A calibrator was installed inside the receiver to monitor detector …
-
Design of an Adiabatic Demagnetization Cryostat for Ultrasonic Studies.
A cryostat for low temperature research was designed with minimal changes to an existing He3 refrigerator. The new design provides for isothermal magnetization and subsequent adiabatic demagnetization of a paramagnetic salt to reach temperatures as low as 0,06°K. The cryostat is to be used for …
-
A Versatile Nuclear Demagnetization Cryostat for Ultralow Temperature Research
A new cascade nuclear demagnetization cryostat has been designed and constructed. Our aim was to build a versatile, modular cryostat, with a large experimental space providing an excellent platform for various types of ultra-low temperature measurements. A powerful dilution refrigerator, combined …
-
Helium Cryostat for Experimental Study of Natural Turbulent Convection
V disertační práci je popsán heliový kryostat s experimentální válcovou konvekční celou pro studium proudění při přirozené konvekci za velmi vysokých Rayleigho čísel Ra (až do řádu 10^15) a Nusseltových čísel Nu (až do řádu 10^4). Pracovní látkou je studené 4He, které umožňuje díky výhodným …
-
Modeling and control of a helium closed cycle calibrating cryostat
<p>A calibrating cryostat serves as a thermal medium for measuring characteristics of extremely low temperature transducers. An isothermal block in the cryostat is required to promote temperature uniformity. Efficient transducer calibration demands that step temperature changes result in …
-
Setup of Dry Cryostat for Measurements on Superconducting Microwave Resonators
A cryogen-free cryostat was set up in order to perform measurements at ultra low temperatures. The setup involved the removal of an adiabatic demagnetization refrigerator (ADR) and replacing it with a dilution refrigerator system. The modified cryostat is able to provide continuous cooling power, …
-
He3 cryostat for steady state nuclear magnetic resonance measurements in metals
A He³ cryostat was designed for steady state nuclear magnetic resonance measurements. The cryostat required about one liter of He³ at NTP. This amount of He³ was liquified at 1.2°K, which was the temperature of the surrounding liquid He⁴ bath, and then pumped on by means of a four-stage mercury …
-
Design and analysis of a superconducting magnet cryostat for traveling heater method growth of CdZnTe
… analysis of a 1.25 Tesla superconducting magnet cryostat system that surrounds the THM furnace with a rotating magnetic field is the focus of this thesis. Individual system components examined include the vacuum vessel, structural supports, current leads, and insulation. Total heat transfer from …
-
The Krypton String Test Cryostat: Characterizing Surface Charge-Induced Dead Layers on High Purity Germanium Detectors
… a germanium test-stand, the Krypton String Test Cryostat (KrSTC). KrSTC uses low energy ($< 40$~keV) photons and electrons to probe the passivated surface of these detectors. Analysis of the KrSTC data shows different low energy spectra depending on detector and cryostat conditions and suggests a …
-
I. Measurements on the nuclear magnetism in liquid HE_. II. A HE_ cryostat for nuclear magnetic resonance measurements
… by the ideal Fermi-Dirac expression. A He3 cryostat has been constructed to extend the measurements to lower temperatures. Both the operating characteristics of a preliminary cryostat and the design of the final cryostat are discussed.
-
Design of Resistivity Instrumentation for a He3 Cryostat and its Application to the Charge Density Wave Superconductor CuxTiSe2
… utilizing an Infrared Labs HDL-10 He3 cryostat. By comparing with data from the literature, doping of two samples was investigated using the new measurement system and a Quantum Design Magnetic Property Measurement System (MPMS). Methods for determining the doping revealed that the old …
-
Modeling He-II cryostat performance and characterization of spin manipulation components for a neutron electric dipole moment experiment at TRIUMF
This thesis chronicles measurements of ultracold neutrons (UCN) performed at TRIUMF in fall 2018 and fall 2019. Heat response data of the UCN source bottle was taken by measuring its temperature using the vapour pressure of the 4He. The time-dependence of the He-II bottle temperature is …
-
Superconductivity in molybdenum
… purity. In initial experiments in a helium-4 cryostat, no superconductivity was observed at temperatures down to about 0.9° K. In order to reach lower temperatures, a helium-3 cryostat of the single condensation type has been built. Details of the design and results of preliminary operation …
-
Wafer Level Characterization of Infrared Detectors
… (MWIR) photonic detectors using a conventional cryostat and a micro-manipulator probe station to extract specific figures of merit needed to assess the device performance. Two different strained-layer super-lattice mid-wave infrared (3-5.5 μm) detectors were characterized using each system to …
-
Συγκριτική ανοσοϊστοχημική μελέτη υποδοχέων οιστρογόνων καρκίνου μαστού σε τομές κρυοστάτη και παραφίνης προς βιοχημικές και ανοσοενζυματικές μεθόδους
… (P.A.P.) method was used to detect the ER in cryostat, paraffin and acetone sections. In 72 of the 86 studied primary breast cancers, a comparative evaluation was done between the semiquantitative ER-ICA method and the quantitative enzyme immunoassay ER-EIA. In 24 of the total 86 cancers …
Page 1 of 15