Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 57 for “"CSA S16"”

  1. Reliability-based development of torsional strength equations for the CSA S16 Standard

    … governed by the Canadian Standards Association (CSA) and designed to CAN/CSA S16-19 – Design of Steel Structures [1]. The current Canadian steel design standard (CSA S16-19) gives no specific guidance on methodology with respect to torsional design. This thesis proposes a reliability-based method …

    newfoundland Repository record for Reliability-based development of torsional strength equations for the CSA S16 Standard (opens in a new tab)

  2. Lateral Torsional Buckling of Welded Wide Flange Beams

    … beam. Design specifications of Canada CSA S16-14 provides solutions for LTB of welded and rolled beams that were derived for constant moment situation. Same equations have been used over the years for design of rolled and welded shape beams. A recent study has shown that the current …

    concordia

  3. Lateral–Torsional Buckling Response of As-built and Heat-straightened Welded Steel Girders

    … top flange and shear centre. The adequacy of the CSA S16-19 design provisions for welded steel girders was then evaluated by comparing the code-predicted moment resistances with those of finite element analysis. The CSA S16-19 design equation is found to adequately estimate the moment resistance …

    alberta Repository record for Lateral–Torsional Buckling Response of As-built and Heat-straightened Welded Steel Girders (opens in a new tab)

  4. Performance of Short and Slender Ultra High Performance Concrete filled Steel Tube and Double Skinned Columns

    … results were compared against the Canadian CSA (CAN/CSA) S16:19 code provisions which were found to overestimate the axial capacity by 12-56%. A modification factor was developed and is recommended to be introduced in the code equation. The second part of the study investigates slenderness …

    queens Repository record for Performance of Short and Slender Ultra High Performance Concrete filled Steel Tube and Double Skinned Columns (opens in a new tab)

  5. Moment-induced block shear failure in bolted flange plate connections

    … and overall connection geometry. In general, the CSA S16-19 design equation was found to provide good predictive capacity for the block shear failure mode, with its assumption of a gross shear area and a higher-than-yield stress state at failure accurately reflecting the observed stresses in the …

    mcgill Repository record for Moment-induced block shear failure in bolted flange plate connections (opens in a new tab)

  6. Performance of seismically deficient existing braced steel frame structures with flexible diaphragms

    … et les détails pour le CCC sont donnés par le CSA S16-09. La philosophie du conception des capacités est utilisé, où un élément fusible est choisi dans un SRFS – pour CCC, les contreventements – est conçu et détaillé pour écouler dans l'évènement d'un fort mouvement du sol. La norme CSA S16-09 …

    mcgill Repository record for Performance of seismically deficient existing braced steel frame structures with flexible diaphragms (opens in a new tab)

  7. Development of a Modular Steel Structure for Multi-Storey Buildings

    … loading code (NBCC) and steel design standard (CSA S16). A braced frame sub-assembly consisting of the first- and second-storey modules was simulated using Abaqus program. A nonlinear static (pushover) analysis was then performed to examine the lateral response of the sub-assembly focusing on …

    alberta Repository record for Development of a Modular Steel Structure for Multi-Storey Buildings (opens in a new tab)

  8. Testing of conventional construction W-shape brace members and their bolted end connections undergoing reversed cyclic loading

    … (CC) décrite à la clause 27.11 de la norme CSA S16-14 qui dit que l'ingénieur est autorisé à déroger aux principes de conception basés sur la capacité et à concevoir un SRCS dont le comportement devrait être principalement élastique. Ces systèmes de type CC sont conçus avec de faibles …

    mcgill Repository record for Testing of conventional construction W-shape brace members and their bolted end connections undergoing reversed cyclic loading (opens in a new tab)

  9. Design of direct- and indirect-formed rectangular hollow section beam-columns

    … Canadian and American steel design standards (CSA S16:19 and AISC 360-22) for RHS members do not account for mechanical differences resulting from different cold-forming techniques (i.e., direct-forming and indirect-forming). Despite these findings, a comparative study on direct- and …

    uvic Repository record for Design of direct- and indirect-formed rectangular hollow section beam-columns (opens in a new tab)

  10. Large-scale Lateral–Torsional Buckling Tests of Welded Girders

    … adequacy of the Canadian steel design standard, CSA S16-14, in characterising the lateral–torsional buckling resistance of members made up of three plates welded together into an I-shaped section, as is commonly done for deep girders. The large heat input from welding results in residual stress …

    alberta Repository record for Large-scale Lateral–Torsional Buckling Tests of Welded Girders (opens in a new tab)

  11. Behaviour of Steel Plate Shear Walls Fabricated with Partially Encased Composite Columns

    … into the Canadian steel design standard, CAN/CSA S16-01, in 2001 and the use of PEC columns as beam-columns is permitted in the current edition, CSA S16-09 (CSA 2009). A half-size two-storey one-bay steel plate shear wall specimen, with PEC columns as the boundary elements, was tested under …

    alberta Repository record for Behaviour of Steel Plate Shear Walls Fabricated with Partially Encased Composite Columns (opens in a new tab)

  12. Finite element analysis of hollow structural sections subject to torsion and combined loading

    … governed by the Canadian Standards Association (CSA) and designed to CAN/CSA S16-19 – Design of Steel Structures [1]. In the United States, steel structures are governed by the American Institute of Steel Construction (AISC) and designed to ANSI/AISC 360-16 – Specification for Structural Steel …

    newfoundland Repository record for Finite element analysis of hollow structural sections subject to torsion and combined loading (opens in a new tab)

  13. Performance of Seismically Deficient Existing Braced Steel Frame Structures With Flexible Diaphragms in Halifax

    … dans le Code nationale de batiment 2010 et le CSA-S16-09 est base sur le principe de calcul par capacite et constate le comportement inelastique cyclique des CCC. Les batiments concus avec ces anciens codes n'avaient aucune exigence de detaillage ou conception particulier pour un comportement …

    mcgill Repository record for Performance of Seismically Deficient Existing Braced Steel Frame Structures With Flexible Diaphragms in Halifax (opens in a new tab)

  14. Seismic Performance and Design of Steel Multi-Tiered Buckling-Restrained Braced Frames

    … in the 2019 Canadian steel design standard, CSA S16-19. Special design requirements were introduced for MT-BRBFs in the 2016 edition of AISC Seismic Provisions in the U.S. to improve column stability response and control tier drift demands. However, very limited supporting research data is …

    alberta Repository record for Seismic Performance and Design of Steel Multi-Tiered Buckling-Restrained Braced Frames (opens in a new tab)

  15. Improved Seismic Design Recommendations for Wide-Flange Columns in Ductile Steel Moment-Resisting Frames considering Three-dimensional Response

    … framework of the Canadian steel design standard (CSA S16). A prototype five-storey Ductile MRF was selected and designed following the CSA S16 seismic design provisions. Various column design scenarios were considered. The concentrated plasticity-based numerical model of the MRF was then …

    alberta Repository record for Improved Seismic Design Recommendations for Wide-Flange Columns in Ductile Steel Moment-Resisting Frames considering Three-dimensional Response (opens in a new tab)

  16. Simplified seismic design methods for low-ductile steel multi-tiered concentrically braced frames

    … in the current Canadian steel design standard (CSA S16), which often requires performing multiple tedious analyses, particularly for tall frames, lack sufficient background research. For Type CC MT-CBFs, the Canadian steel design standard does not provide specific seismic design requirements. …

    alberta Repository record for Simplified seismic design methods for low-ductile steel multi-tiered concentrically braced frames (opens in a new tab)

  17. Block shear failures in W-section tension members connected by bolted flange plates

    … des règles de calcul des charpentes en acier CSA S16-14.Une étude numérique par éléments finis a été complétée utilisant le logiciel ABAQUS dans le but de prévoir les modes de défaillance des spécimens avant leur expérimentation. Après la séance d'expérimentation, le modèle numérique a été …

    mcgill Repository record for Block shear failures in W-section tension members connected by bolted flange plates (opens in a new tab)

  18. Design, Modeling, and Nonlinear Response of Linked Column Frame with Multiple Links under Crustal and Subduction Zone Earthquakes.

    … and a design methodology complying with NBC and CSA S16 standard requirements was not proposed. The main objectives are: • Propose a forced-based design method for the LCF system with single and multiple links per floor using the current NBC 2015 and CSA S16-14 standard requirements. • Develop a …

    concordia

  19. Collapse Assessment of Steel Plate Shear Walls

    … and composite SPSWs were designed according to CSA S16-14 and NBC 2015. To estimate the seismic response parameters (i.e., ductility-related force modification factor and overstrength-related force modification factor) for designing stiffened and composite SPSWs, nonlinear static pushover …

    concordia