Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"CSA S806-12"”

  1. Finite Element Modelling of FRP Reinforced Concrete Beams and Comparative Analysis of Current Strength Prediction Methods

    … Finally, a parametric study was conducted on 12 GFRP reinforced beams, over 12 slenderness ratios, to study the effects of slenderness. The database of tested beams consisted of beams that failed in shear, as tests on slender beams reinforced with FRP are scarce. The strength prediction models …

    waterloo Repository record for Finite Element Modelling of FRP Reinforced Concrete Beams and Comparative Analysis of Current Strength Prediction Methods (opens in a new tab)

  2. Flexural and Shear Behaviour of Fibre-Reinforced Concrete Beams Reinforced with GFRP Bars

    … the deflection equations outlined in the CSA S806-12 and ACI 440.11-22 standards, alongside assessing flexural capacity in accordance with ACI 544.4R-18. Furthermore, digital image correlation (DIC) was utilized to capture the crack propagation, crack width, and deflection up to failure, …

    concordia

  3. GFRP-reinforced concrete exterior beam-column joints subjected to seismic loading

    … However, the current Canadian FRP design codes (CSA 2012, CSA 2006) have no considerable seismic provisions, if any, due to lack of data and research in this area. Such lack of information does not allow for adequate designs and subsequently limits the implementation of FRP reinforcement as a …

    manitoba Repository record for GFRP-reinforced concrete exterior beam-column joints subjected to seismic loading (opens in a new tab)

  4. Development Length and Bond Strength of FRP Bars Embedded in Normal, High Strength, and Ultra-High-Performance Concrete

    … to 23 db for the 8 mm bar. ACI440.1R-15 and CAN/CSA S806-12 design guides overestimated Ld of these small diameter bars. Alternative equations for splitting and pullout are proposed and explained herein. For the second study investigating sand coated GFRP bars, the embedment length was varied …

    queens Repository record for Development Length and Bond Strength of FRP Bars Embedded in Normal, High Strength, and Ultra-High-Performance Concrete (opens in a new tab)

  5. Acoustic emission monitoring of damage progression in fiber reinforced polymer rods

    … engineering applications. According to the CAN/CSA-S806-12 standard, the maximum recommended stress in FRP bars under service loads should not exceed 25% and 65% of the ultimate strength for glass FRP (GFRP) and carbon FRP (CFRP), respectively. These stress values are set to prevent creep …

    manitoba Repository record for Acoustic emission monitoring of damage progression in fiber reinforced polymer rods (opens in a new tab)

  6. Finite element analysis of CFRP prestressed concrete beams

    … formulas shows that the formula given by the CSA S806-12 gives similar a/d dependency but lower values of shear resistance than the analysis.

    manitoba Repository record for Finite element analysis of CFRP prestressed concrete beams (opens in a new tab)

  7. Investigation of Shear-critical One-way Concrete Slabs Internally Reinforced with GFRP Bars

    … design codes including ACI440.1R-15, CAN/CSA S6-14, CAN/CSA S806-12, and previously suggested modifications incorporating 2nd orders of  and θ. A new optimized equation was proposed for mid-depth longitudinal strain, and improvement was observed in the prediction of shear capacities …

    toronto-retro Repository record for Investigation of Shear-critical One-way Concrete Slabs Internally Reinforced with GFRP Bars (opens in a new tab)

  8. Shear Strengthening of RC Beams Using Externally Bonded and Anchored FRP U-wraps

    … a variable shear crack inclination angle in the CSA S806-12 (2012) standard led to overestimated shear resistance predictions for beams with a single shear crack, therefore a conservative 45 degree shear crack inclination is recommended for design. The use of the proposed carbon anchors resulted …

    mcmaster Repository record for Shear Strengthening of RC Beams Using Externally Bonded and Anchored FRP U-wraps (opens in a new tab)

  9. Système d'ancrage en étriers fermés pour le renforcement à l'effort tranchant des poutres en béton armé à l'aide de composites en PRF

    … par les principaux manuels de conception, dont CSA-S806-12, CSA-S6-14, ACI 440.2R-08 et fib TG-9.3-01. Les résultats de cette étude montrent que les deux systèmes d’ancrage améliorent substantiellement la contribution du PRF à la résistance au cisaillement. Ils confirment également l’existence …

    ets-quebec

  10. Behaviour of GFRP-RC continuous deep beams without web reinforcement

    … the predicted values by the Canadian standards CSA/S806-12 (CSA 2012) and CSA/A23.3-14 (CSA 2014), and the American Code ACI 318-14 (ACI 2014). The test results confirmed the formation of the Strut-and Tie-Model (STM). In addition, it was observed that increasing the shear span-to-depth ratio …

    manitoba Repository record for Behaviour of GFRP-RC continuous deep beams without web reinforcement (opens in a new tab)

  11. Experimental Evaluation of Biochar as Supplementary Cementitious Material in Reinforced Concrete

    … deflections and crack widths met the limits in CSA A23.3:24, CSA S806-12, ACI 318-25, and ACI 440.11-22, with crack patterns similar across mixes. Biochar increased shear capacity of RC beams by ~30% with 4% biochar and ~40% with 6% biochar, where diagonal shear cracking load rose by ~37% with …

    alberta Repository record for Experimental Evaluation of Biochar as Supplementary Cementitious Material in Reinforced Concrete (opens in a new tab)

  12. Structural Behaviour of Conventional and FRP- Reinforced Concrete Deep Beams

    … of the relevant Canadian standard (i.e., CAN/CSA S-806-12) which came out much later than the commencement of the present research, an STM approach has been provided, which is primarily based on that of conventional deep beams with some adjustments by using FRP reinforcement’s properties to …

    concordia

  13. Serviceability and Ultimate Performance of Steel and Chopped Glass Fibre Reinforced Concrete Flexural Members: Experimental and Analytical Study

    … of 147 tests documented in the literature. The CSA S806-12 standard is considered the most consistent at predicting shear strength. Lastly, this study used the numerical database from FEA to develop service and ultimate design equations for FRC with SR and GFRP bars. The flexural and shear …

    alberta Repository record for Serviceability and Ultimate Performance of Steel and Chopped Glass Fibre Reinforced Concrete Flexural Members: Experimental and Analytical Study (opens in a new tab)

  14. Behaviour of continuous concrete deep beams reinforced with GFRP bars

    … ratio achieved the minimum requirements of the CSA S806-12. The experimental results highlighted that the web reinforcement ratio improved the load capacities by about 10% and 18% for specimens having 𝑎/ℎ ratios of 1.0 and 1.7, respectively. For specimens with web reinforcement, the increase of …

    bradford Repository record for Behaviour of continuous concrete deep beams reinforced with GFRP bars (opens in a new tab)

  15. Long-term behaviour of GFRP prestressed concrete beams

    … Also, no design guidelines are provided by CAN/CSA-S806-12 or ACI 440.4R-04 for using prestressed GFRP bars in concrete members. This research study consisted of experimental and analytical phases, and was designed to assess the long-term properties of a concrete beams prestressed with a new …

    waterloo Repository record for Long-term behaviour of GFRP prestressed concrete beams (opens in a new tab)

  16. Bond Behaviour of Concrete Beams with Glass Fibre Reinforced Polymer Bars Under Fatigue Loading

    … Also, no design guidelines are provided in CAN/CSA-S806-12 or ACI 440.4R-04 for using prestressed GFRP bars in concrete members. In order to address this knowledge gap, the current study included testing of forty-six GFRP reinforced concrete beams to investigate the bond mechanisms between the …

    waterloo Repository record for Bond Behaviour of Concrete Beams with Glass Fibre Reinforced Polymer Bars Under Fatigue Loading (opens in a new tab)

  17. Využití vnitřní kompozitní výztuže při návrhu odolných betonových konstrukcí

    Diplomová práce se zabývá zpracováním způsobu stanovení smykové únosnosti betonových konstrukcí vyztužených kompozitní výztuží, při namáhání posouvající silou, dle pěti různých návrhových přístupů. Teoretická část práce je úzce navázána na výzkumný projekt FW01010520 – „Vývoj ohýbané kompozitní …

    brno-tech Repository record for Využití vnitřní kompozitní výztuže při návrhu odolných betonových konstrukcí (opens in a new tab)

  18. Μηχανισμοί αστοχίας και πειραματική διερεύνηση στοιχείων ωπλισμένου σκυροδέματος με προβλήματα διάτμησης

    … of three available codes (JSCE-97 1997, CSA S806-12 2012, ACI 440.1R-15 2015) are also included in this research. From these comparisons it is observed that the developed approach provides greater accuracy regarding the ultimate strength of the examined cases compared with the existing …

    greece Repository record for Μηχανισμοί αστοχίας και πειραματική διερεύνηση στοιχείων ωπλισμένου σκυροδέματος με προβλήματα διάτμησης (opens in a new tab)