Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 21 for “"CT Protocol"”
-
Comparison of concurrent chemoradiotherapy versus sequential radiochemotherapy in patients with completely resected non-small cell lung cancer
… has executed two different kinds of adjuvant protocols in treating patients with non-small cell lung cancer (NSCLC): 1) chemotherapy followed by concurrent chemoradiotherapy (CTx-CCRT) and 2) sequential postoperative radiotherapy (PORT) followed by postoperative chemotherapy (POCT) (i.e. …
-
Iterative reconstruction as a novel method of radiation dose reduction at computed tomography in patients with Crohn's disease
… medical imaging and the notable shift towards CT imaging making these patients an at risk group, provided context for this work. CT delivers some of the highest doses of ionising radiation in diagnostic radiology. Once a medical imaging examination is deemed justified, there is an onus on the …
-
The non-drug management of patients with chronic gastrointestinal disease
… embodied in this thesis explores various aspects of health for patients with chronic gastrointestinal disease. By analysing additional factors to the primary disease component, such as inflammatory bowel disease, it is hoped that the overall health of such patients may be improved. Dietary …
-
Computed tomography technique for the measurement of bone defects adjacent to uncemented acetabular components of total hip replacement: development, validation and clinical application.
… of which was to develop a computed tomography (CT) technique that provides accurate and reliable volumetric measurement of bone defects adjacent to uncemented metal-backed acetabular components of total hip replacement (THR). Periprosthetic osteolysis (PO) around THR is a major clinical problem …
-
Design and Evaluation of the Kingston Brace
Lisfranc injuries affect at least 1 out of every 55,000 people each year. Although they are rare foot injuries, their effects can be devastating. 20-40% of Lisfranc injuries are missed upon first presentation. This increases the number of poor outcomes, resulting in a disproportionate number of …
-
Comparison of a Patient-Specific Computed Tomography Organ Dose Software with Commercial Phantom-Based Tools
… dose used to form the image. Currently, CT scanners report a measure of radiation dose for each scan that reflects the radiation emitted by the scanner, not the radiation dose absorbed by the patient. The radiation dose absorbed by organs, known as organ dose, is a more relevant metric …
-
Humeral Torsion and Shoulder Biomechanics: Comparison of a novel ultrasonographic technique with the computed tomography benchmark
… an internal twist or antetorsion, as daily activities are anterior to the body. However, the strong posterior stress induced by an overhead throwing motion may counteract this internal twist in young athletes and cause prominent bilateral dimorphism. To measure torsion in these young …
-
Evaluation of the Normal Equine Pituitary Gland
Computed tomography (CT) is becoming more available as a diagnostic tool in the evaluation of the equine skull and brain. Objectives of this study were: 1) refine a CT protocol for evaluating the equine pituitary gland, 2.) define the CT anatomy of the pituitary region, 3.) determine a set of …
-
The influence of complex training design on post-activation performance enhancement of explosive performance in team sport athletes
Post-activation performance enhancement (PAPE) is a phenomenon characterised by the acute enhancement of muscular performance consequent to prior voluntary, dynamic contractile activity, and is the premise underpinning complex training (CT). CT involves alternating a conditioning stimulus (CS) with …
-
Standardisation of preclinical PET/CT protocols across multiple research centres
… Emission Tomography/Computed Tomography (PET/CT) is a well-established non-invasive imaging tool for studying disease development/progression, the development of novel radiotracers and pharmaceuticals for clinical applications. Over the last five years more than 8,200 preclinical studies using …
-
Vaizdų kokybės ir apšvitos optimizavimas vaikų nesindrominių kraniosinostozių kompiuterinėje tomografijoje /
Exposure of children to ionizing radiation during CT examinations is problematic due to the risk of developing cancer. The main purpose of the dissertation is to develop a CT dose optimization algorithm based on the generation of ultra-low dose CT images from retrospective images using modification …
-
Morphologische und funktionelle Bildgebung mittels hochauflösender 3.0 Tesla Multi-Sequenz Magnetresonanztomographie und 18F-Fluorodesoxyglukose PET Computertomographie bei Patienten mit spontanen Dissektionen der Halsgefäße
… 2010 more than 50 patients with spontaneous dissections of cervical arteries have been examined and scanned with a modified cervical MRI and fluorodeoxyglucose (18F) PET CT protocol at the Institute of Clinical Radiology, LMU Munich. Within this prospective, mono-centric study all imaging data was …
-
Bromodomain and Extraterminal Domain (BET) Inhibitor RVX-208 Ameliorates Periodontal Bone Loss
Periodontal disease affects 47% of Americans over 30 and is a growing global concern. Current treatments for periodontal disease focus on the mechanical elimination of periodontal biofilms. Very few treatments are available that target the rampant, unregulated host immune response that is …
-
Image Quality Optimisation and Dose Management in CT, SPECT/CT, and PET/CT
The significant increase in the use of CT, alone or combined with SPECT or PET, has raised concerns about patient radiation exposure and the consequent increased risk of malignancy later in life. The overall objective of this work was to evaluate and optimise different approaches for minimising …
-
Ganzkörper-CT Untersuchungen bei Patienten nach Polytrauma – Untersuchungen zur Strahlendosis und Potentiale zur Dosisreduktion
… die Aspekte der applizierten Strahlendosis bei GKCT-Untersuchungen von Polytrauma-Patienten befassen. Ziele des Promotionsprojektes sind die Evaluation von Hardware- und Software-Entwicklungen auf dem Gebiet der CT und die Untersuchung von deren Einfluss auf die Strahlenexposition von Schwer- oder …
-
A Novel In Vivo Synchrotron Radiation Micro-CT Imaging Platform For The Direct Tracking Of Remodeling Events In Cortical Bone
… bone tissue continuously alters its microarchitecture in response to microdamage and other stimuli through remodeling. Specialized cellular groupings, Basic Multicellular Units (BMUs), conduct remodeling through ‘coupling’ bone resorption to formation. Osteoclasts within a BMU’s cutting cone …
-
Truth-based Radiomics for Prediction of Lung Cancer Prognosis
… purpose of this dissertation was to improve CT-based radiomics characterization by assessing and accounting for its systematic and stochastic variability due to variations in the imaging method. The anatomically informed methodologies developed in this dissertation enable radiomics studies to …
-
Impact of acquisition protocol variations on effective dose and risk for CT head examinations
… To propose a method for estimating the effective lifetime risk of radiation-induced cancer from different brain CT scan protocols in both paediatrics and adults and to develop a prospective method for estimating the number of cancer cases for patients undergoing CT brain scans when using …
-
Stratégies d’optimisation des protocoles en scanographie pédiatrique
… développer des stratégies d’optimisation sur les protocoles cliniques en utilisant des méthodes de simulation et de modélisation permettant de comprendre l’influence des paramètres des protocoles sur les indicateurs de qualité d’image et sur la dose délivrée au patient. Ce travail se divise en …
-
Prospective Estimation of Radiation Dose and Image Quality for Optimized CT Performance
<p>X-ray computed tomography (CT) is a non-invasive medical imaging technique that generates cross-sectional images by acquiring attenuation-based projection measurements at multiple angles. Since its first introduction in the 1970s, substantial technical improvements have led to the expanding use …
Page 1 of 2