Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 258 for “"CT data"”.

  1. Iterative Reconstruction of Cone-Beam Micro-CT Data

    <p>The use of x-ray computed tomography (CT) scanners has become widespread in both clinical and preclinical contexts. CT scanners can be used to noninvasively test for anatom- ical anomalies as well as to diagnose and monitor disease progression. However, the data acquired by a CT scanner must be …

    utk-theses Repository record for Iterative Reconstruction of Cone-Beam Micro-CT Data (opens in a new tab)

  2. High-resolution CT data acquisition software and 3D visualization tool

    <p>Computer tomography (CT) technology which allows cross sectional imaging of objects without disassemble them plays an important role in diagnostic medicine and industry nondestructive evaluation. Modem CT data acquisition systems can collect a large amount of CT data to construct the interior …

    iastate Repository record for High-resolution CT data acquisition software and 3D visualization tool (opens in a new tab)

  3. Neural-Network-Based Detection of Radiopharmaceutical Extravasation In PET/CT Data

    <p>The immediate identification of PET/CT radiopharmaceutical extravasation can eliminate many adverse effects such as misdiagnosis and improper therapy. Radiopharmaceutical extravasation is the leakage of an injected radiotracer from the patient’s intended vein into surrounding tissues. The …

    ut-knoxville Repository record for Neural-Network-Based Detection of Radiopharmaceutical Extravasation In PET/CT Data (opens in a new tab)

  4. Itera- tive Reconstruction Framework for High-Resolution X-ray CT Data

    … and therapy response. Currently, clinical CT scanners typically use a Filtered Backprojection (FBP) based method for image reconstruction. This algorithm is fast and generally produces acceptable results, but has several drawbacks. Firstly, it is based upon line integrals, which do not …

    ut-knoxville Repository record for Itera- tive Reconstruction Framework for High-Resolution X-ray CT Data (opens in a new tab)

  5. Feature Based Registration of Ultrasound and CT Data of a Scaphoid

    Computer assisted surgery uses a collection of different techniques including but not limited to: CT-guided, fluoroscopy-guided, and ultrasound-guided imaging which allows medical staff to view bony anatomy of a patient in relation to surgical tools on a computer screen. By providing this visual …

    queens Repository record for Feature Based Registration of Ultrasound and CT Data of a Scaphoid (opens in a new tab)

  6. Quantitative analysis of breast lumpectomies using histology and micro-CT data

    OBJECTIVE: Breast cancer represents a significant risk in women's health, affecting many women worldwide. Current treatment options in the U.S involve a multidisciplinary approach, most often beginning with surgery to remove cancerous tissue. Evaluation of margins for cancer on excised tissue is an …

    bu Repository record for Quantitative analysis of breast lumpectomies using histology and micro-CT data (opens in a new tab)

  7. Segmenting contrast-enhanced CT images for attenuation correction of PET/CT data

    … emission tomography (PET)/computed tomography (CT) dual modality imaging has been shown to cause artifacts in the PET image. These artifacts are attributed to an overestimation of the PET attenuation coefficients, which are obtained from contrast-enhanced CT numbers. This dissertation evaluates …

    rice Repository record for Segmenting contrast-enhanced CT images for attenuation correction of PET/CT data (opens in a new tab)

  8. An Application of Real-Time Error Control Processing to CT Data Communications

    … generation of x-ray based computed tomography (CT) medical imaging scanners is emerging which will provide high resolution images of human anatomy with one second scan times. The high speed data communication channel which carries x-ray detector information passes through an electrically and …

    marquette Repository record for An Application of Real-Time Error Control Processing to CT Data Communications (opens in a new tab)

  9. High-Resolution X-Ray Image Generation from CT Data Using Super-Resolution

    Synthetic X-ray or digitally reconstructed radiographs (DRRs) are simulated X-ray images projected from computed tomography (CT) data that are commonly used for CT and real X-Ray image registration. High-quality synthetic X-ray images can facilitate various applications such as guiding images for …

    ottawa-retro Repository record for High-Resolution X-Ray Image Generation from CT Data Using Super-Resolution (opens in a new tab)

  10. 3D IMAGE ANALYSIS OF CT DATA OF CONCRETE CYLINDER SUNDERGOING DELAYED ETTRINGTIE FORMATION

    … change between the inert aggregates and the reactive cement paste will produce variations in local displacements that cannot be detected by the linear expansion variable. With CT slices offered by Simultaneous neutron and X-ray computed tomography (SNXCT), this thesis applies image analysis …

    maryland Repository record for 3D IMAGE ANALYSIS OF CT DATA OF CONCRETE CYLINDER SUNDERGOING DELAYED ETTRINGTIE FORMATION (opens in a new tab)

  11. IIR Digital Filter (For CT Data Collection System at G.E. medical Systems Div.)

    … Impulse Response (IIR) Digital Filter in the CT Data Collection System is studied. The material is presented with the assumption that one has a basic understanding of analog filters and z-transforms. Some knowledge of digital filters would also be helpful. Chapter 1 begins with a description …

    marquette Repository record for IIR Digital Filter (For CT Data Collection System at G.E. medical Systems Div.) (opens in a new tab)

  12. A study on methods to improve X-ray CT data quality of composites

    Better characterisation of the meso-structure of carbon-fibre reinforced polymer composites (CFRPs), including features such as ply-drops, tape gaps and overlaps, in-plane fibre orientation and out-of-plane wrinkling can only be achieved with high-quality non-destructive testing (NDT) data. X-ray …

    bristol Repository record for A study on methods to improve X-ray CT data quality of composites (opens in a new tab) Download PDF for A study on methods to improve X-ray CT data quality of composites (opens in a new tab)

  13. Novel image processing and deep learning methods for liver cancer delineation from CT data

    … segmenting and identifying anatomical structures and lesion areas, the processed images can provide highresolution and quantitative anatomical information to help clinicians develop more effective and personalized treatment plans. In liver surgery or tumour radiotherapy, accurate image …

    strathclyde Repository record for Novel image processing and deep learning methods for liver cancer delineation from CT data (opens in a new tab)

  14. Automatic colonic polyp detection using curvature analysis for standard and low dose CT data

    … deaths in the developed nations. Early detection and removal of colorectal polyps via screening is the most effective way to reduce colorectal cancer (CRC) mortality. Computed Tomography Colonography (CTC) or Virtual Colonoscopy (VC) is a rapidly evolving non-invasive technique and the …

    dcu Download PDF for Automatic colonic polyp detection using curvature analysis for standard and low dose CT data (opens in a new tab)

  15. Sub-pixel Registration In Computational Imaging And Applications To Enhancement Of Maxillofacial Ct Data

    In computational imaging, data acquired by sampling the same scene or object at different times or from different orientations result in images in different coordinate systems. Registration is a crucial step in order to be able to compare, integrate and fuse the data obtained from different …

    ucf Repository record for Sub-pixel Registration In Computational Imaging And Applications To Enhancement Of Maxillofacial Ct Data (opens in a new tab)

  16. Automation Process for Morphometric Analysis of Volumetric CT Data from Pulmonary Vasculature of Rats

    … analysis of the rat lung vascular structure. The primary objective of our group is to develop a structural and functional understanding of pulmonary vascular remodeling (PVR). PVR can be defined as certain structural as well as biomechanical changes in the normal architecture of the …

    marquette Repository record for Automation Process for Morphometric Analysis of Volumetric CT Data from Pulmonary Vasculature of Rats (opens in a new tab)

  17. Estimating Root Volumes by Limited Segmentation: A Volumetric Analysis of CBCT and Micro-CT Data

    Introduction: The increased dimensional accuracy of images provided by cone beam computed tomography (CBCT) scans allows for more in-depth diagnosis and treatment planning. Expedient interpolation of segmented data that provides clinically acceptable results will encourage clinicians to frequently …

    loma-linda Repository record for Estimating Root Volumes by Limited Segmentation: A Volumetric Analysis of CBCT and Micro-CT Data (opens in a new tab)

Page 1 of 13