Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 194 for “"CT scanner"”.

  1. Calibration of a Mobile-Gantry CT Scanner for Surgical Navigation

    … of the images to the patient. In a direct navigation system, such an intra-operative registration is replaced with pre-operative patient-independent calibration in a process that determines the relationship between the coordinate frame of imaging equipment and the coordinate frame of the …

    queens Repository record for Calibration of a Mobile-Gantry CT Scanner for Surgical Navigation (opens in a new tab)

  2. DESIGN AND DEVELOPMENT OF A MEGAVOLTAGE CT SCANNER FOR RADIATION THERAPY.

    … has been modified to perform also as a CT scanner. The goal is to provide low cost computed tomography capability for use in radiotherapy. The system will have three principal uses. These are (i) to provide 2- and 3-dimensional maps of electron density distribution for CT assisted …

    arizona-thes Repository record for DESIGN AND DEVELOPMENT OF A MEGAVOLTAGE CT SCANNER FOR RADIATION THERAPY. (opens in a new tab)

  3. Quantitative radionuclide imaging with a state-of-the-art preclinical PET/CT scanner

    … by a state-of-the-art commercial preclinical PET-CT scanner. <br/>First, a performance evaluation of the scanner was carried out based on the recommendations of the National Electrical Manufacturers Association both of the prototype and a production version of the scanner. The scanner was found to …

    kings Repository record for Quantitative radionuclide imaging with a state-of-the-art preclinical PET/CT scanner (opens in a new tab) Download PDF for Quantitative radionuclide imaging with a state-of-the-art preclinical PET/CT scanner (opens in a new tab)

  4. Advances of Interfacial Property Determination Using X-Ray Micro Imaging

    The main objectives of this research project are to analyze the challenges X-ray micro imaging has to determine interfacial properties, propose a solution to be able to implement X-rays in the determination of contact angle and interfacial tension and establish the reliability and practicality of …

    calgary Repository record for Advances of Interfacial Property Determination Using X-Ray Micro Imaging (opens in a new tab)

  5. Method of Tolerance Allocation to Maintain Rotary Balance of Multi-Component Bodies

    … and also the most preventable. In the case of a CT scanner, unwanted vibration in the equipment causes artifacts to the X-ray image, and therefore all measures are taken to eliminate imbalance. The CT scanner is a multi-component rotating body, therefore making it a challenge to account for many …

    marquette Repository record for Method of Tolerance Allocation to Maintain Rotary Balance of Multi-Component Bodies (opens in a new tab)

  6. Investigating the changes in matrix and fracture properties and fluid flow under different stress-state conditions

    The fracture aperture and fracture permeability are usually considered to remain the same during the production life of a naturally fractured reservoir, regardless of the degree of depletion; but reservoirs experience different stress state conditions, therefore understanding the fracture behavior …

    tamu Repository record for Investigating the changes in matrix and fracture properties and fluid flow under different stress-state conditions (opens in a new tab)

  7. Theoretical and Experimental Evaluation of Spatial Resolution in a Variable Resolution X-Ray Computed Tomography Scanner

    … resolution x-ray (VRX) computed tomography (CT) scanner can image objects of various sizes with greatly improved spatial resolution. The scanner employs an angulated discrete detector and achieves the resolution boost by matching the detector angulation to the scanner field of view (FOV) …

    tenn-hsc Repository record for Theoretical and Experimental Evaluation of Spatial Resolution in a Variable Resolution X-Ray Computed Tomography Scanner (opens in a new tab)

  8. Using Thermoluminescent Dosimeters to Measure the Dose From High and Low Energy X-Ray Sources

    … to measure the doses from two x-ray sources, a CT scanner and a linear accelerator (linac). In addition ion chambers were used to determine the isodose contours from the operation of the linac. 1mm x 1mm x 1mm TLD-100 microcubes were placed in a Lawrence Livermore National Laboratory (LLNL) …

    unlv Repository record for Using Thermoluminescent Dosimeters to Measure the Dose From High and Low Energy X-Ray Sources (opens in a new tab) Download PDF for Using Thermoluminescent Dosimeters to Measure the Dose From High and Low Energy X-Ray Sources (opens in a new tab)

  9. Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry

    … dose verification. While they offer a distinct advantage, their application is intricate, requiring specialized expertise for accurate readout. Optical computed tomography (CT) stands out as a primary modality for imaging three-dimensional dosimeters used in validating complex radiotherapy …

    ubc Repository record for Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry (opens in a new tab) Download PDF for Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry (opens in a new tab)

  10. Investigation of CT dosimetry techniques for use in optimisation of Automatic Tube Current Modulation (ATCM) performance

    The PhD project aimed to develop methodologies for optimisation of automatic tube current modulation (ATCM) performance for the four most important computed tomography (CT) scanner manufacturers (Toshiba, GE, Philips and Siemens scanners). Since the human body to which ATCM response is elliptical …

    glasgow Download PDF for Investigation of CT dosimetry techniques for use in optimisation of Automatic Tube Current Modulation (ATCM) performance (opens in a new tab)

  11. CT fan beam reconstruction with a non-stationary axis-of-rotation

    <p>One important aspect for reconstructing an image using Computed Tomography (CT) is that the axis-of-rotation must pivot at the same point on the reconstruction plane as the x-ray source and CT scanner assembly rotates around the imaged object. This pivot point is used as a reference point for …

    njit Repository record for CT fan beam reconstruction with a non-stationary axis-of-rotation (opens in a new tab)

  12. Alpha Taxonomy of Eocene Primates from the Great Divide Basin, Wyoming

    … identification of the alpha taxonomy of an extinct species is the first step towards understanding its evolutionary history and relationships with other organisms. Alpha taxonomy refers to the initial classification of the specimen based on the analysis of the observable morphological traits. …

    ecu Repository record for Alpha Taxonomy of Eocene Primates from the Great Divide Basin, Wyoming (opens in a new tab)

  13. A System For Computer-Assisted Surgery With Intraoperative CT Imaging

    … a method for computer-assisted surgery using direct navigation on intraoperative images is presented. In this system the registration step of a navigated procedure was divided into two stages: preoperative calibration of images to a ceiling-mounted optical tracking system, and intraoperative …

    queens Repository record for A System For Computer-Assisted Surgery With Intraoperative CT Imaging (opens in a new tab)

  14. Implementing Radformation at Personalized Radiation Oncology: Enhancing Efficiency and Precision

    … assurance (QA) tests. It offers various functions assisting medical physicists in a radiation oncology clinic, including inputting, analyzing, managing, exporting, and monitoring QA data. Physicists create test lists following the recommendations provided by the American Association of …

    unlv Repository record for Implementing Radformation at Personalized Radiation Oncology: Enhancing Efficiency and Precision (opens in a new tab) Download PDF for Implementing Radformation at Personalized Radiation Oncology: Enhancing Efficiency and Precision (opens in a new tab)

  15. Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy

    This thesis describes the construction and use of the facemask at the National Accelerator Centre (NAC) as used to both immobilise and position patients for precision proton radiotherapy. The precision achieved using the stereophotogrammetric (SPG) positioning system is measured, and the …

    cape-town Repository record for Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy (opens in a new tab)

  16. Διερεύνηση εξαρτηματικών μαζών με αξονική τομογραφία και μαγνητική τομογραφία

    Characterization of adnexal masses is of outmost importance in the preoperative evaluation of these patients. The purpose of this prospective study was to compare the accuracy of multidetector CT on a 16-row CT scanner and MR imaging in the detection and characterization of adnexal masses. …

    greece Repository record for Διερεύνηση εξαρτηματικών μαζών με αξονική τομογραφία και μαγνητική τομογραφία (opens in a new tab)

Page 1 of 10