Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 32 for “"CUFF electrode"”

  1. Optimisation of Nerve Cuff Electrode Recordings for Functional Electrical Stimulation Applications

    … activity recorded from peripheral nerves using cuff electrodes have been shown to be a reliable source of feedback in FES applications, eliminating most of the problems faced with externally-worn sensors. This thesis is dedicated to the optimisation of cuff electrodes in FES applications in …

    ucl Repository record for Optimisation of Nerve Cuff Electrode Recordings for Functional Electrical Stimulation Applications (opens in a new tab)

  2. Directionally Sensitive Low-noise Neural Recording Using Tetrapolar Nerve Cuff Electrode

    … implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving good signal-to-noise (SNR) recordings and suitable for chronic implant. However, the symmetrical geometry of this electrode array – electrically-shorted side contacts – …

    toronto-retro Repository record for Directionally Sensitive Low-noise Neural Recording Using Tetrapolar Nerve Cuff Electrode (opens in a new tab)

  3. Discrimination of Neural Sources using Spatiotemporal Signatures in Nerve Cuff Electrode Recordings

    … neural recordings remain a challenge. Nerve cuff electrodes are an option that have demonstrated chronic viability in humans but lack the required recording selectivity. The objective of this thesis was to increase the recording selectivity achievable using multi-contact nerve cuff …

    toronto-retro Repository record for Discrimination of Neural Sources using Spatiotemporal Signatures in Nerve Cuff Electrode Recordings (opens in a new tab)

  4. Motion control of neuromuscular skeletal systems using a multiple contact nerve cuff electrode

    A flat interface nerve electrode (FINE) is a type of nerve cuff electrode designed to increase spatial selectivity by reshaping a nerve and realigning fascicles inside the nerve trunk. FINE has shown improved fascicular and subfascicular selectivity enabling the activation of many muscles with a …

    ohiolink Repository record for Motion control of neuromuscular skeletal systems using a multiple contact nerve cuff electrode (opens in a new tab)

  5. THE DEVELOPMENT AND CHARACTERIZATION OF NON-LINEAR ROUTING WIRE BONDING PROCESS FOR HIGH-DENSITY CUFF ELECTRODE CONNECTOR

    … the application of neural interfaces to bridge electrode contacts and larger discrete wires. A robust interconnect system should conduct electrical signals while serving as a mechanical buffer between flexible nerve electrodes and bulky discrete wire bundles near the implantation site. An …

    ohiolink Repository record for THE DEVELOPMENT AND CHARACTERIZATION OF NON-LINEAR ROUTING WIRE BONDING PROCESS FOR HIGH-DENSITY CUFF ELECTRODE CONNECTOR (opens in a new tab)

  6. Propagation of mechanical strain in peripheral nerve trunks and their interaction with epineural structures

    Advances in peripheral nerve electrode technology have outpaced the advances in chronic implantation reliability of the electrodes. An observable trend is the increased deposition of fibrotic encapsulation tissue around the electrode to shift its position away from the implantation site and …

    iupui Repository record for Propagation of mechanical strain in peripheral nerve trunks and their interaction with epineural structures (opens in a new tab)

  7. CLINICAL IMPLEMENTATION OF NERVE CUFF ELECTRODES FOR AN UPPER EXTREMITY NEUROPROSTHESIS

    … neuroprostheses consists of muscle-based electrodes. However, nerve electrodes are emerging as a tool to provide increased benefit for increasingly complicated systems. Many types of nerve electrodes have been developed and tested in animals but few have been transferred to clinical use …

    ohiolink Repository record for CLINICAL IMPLEMENTATION OF NERVE CUFF ELECTRODES FOR AN UPPER EXTREMITY NEUROPROSTHESIS (opens in a new tab)

  8. Acquisition and Time Delay Estimates of Canine Gastric Nerve Signals

    … I have developed a cannula system with nerve cuff electrodes, subserosal bipolar electrodes, and extraluminal strain gauges to simultaneously monitor the vagal nerve, myoelectric (ECA), and contractile activities in chronic dogs. The cuff electrodes were used to both stimulate and record nerve …

    mcmaster Repository record for Acquisition and Time Delay Estimates of Canine Gastric Nerve Signals (opens in a new tab)

  9. Computational Modeling to Evaluate Bipolar Flexible Electrode Designs for Use in Sciatic Nerve Stimulation

    … and clinical relevance. A conventional nerve cuff electrode is the least invasive method for nerve stimulation, but the mismatch of mechanical properties of the electrode with the nerve tissue can cause damage to the nerve and the electrode itself. This study investigated a novel bipolar, gold …

    calpoly Repository record for Computational Modeling to Evaluate Bipolar Flexible Electrode Designs for Use in Sciatic Nerve Stimulation (opens in a new tab)

  10. Improving Neuroprosthesis-Assisted Standing with Nerve-Based Stimulating Electrodes

    … and buckling at the knee joints. Multi-contact electrodes have the potential to increase muscle recruitment and improve the performance of FNS systems for standing after SCI. By selectively activating multiple populations of motor units within the quadriceps, these electrodes can more completely …

    ohiolink Repository record for Improving Neuroprosthesis-Assisted Standing with Nerve-Based Stimulating Electrodes (opens in a new tab)

  11. Bio-implantable microdevices and structures for functional electrical stimulation applications

    … in functional electrical stimulation. A nerve cuff electrode design has been developed for applications in neural electrical stimulation and recording, which addresses limitations with existing cuff electrodes. The developed clip-on micro-cuff electrode design consists of a naturally closed …

    lsu-thes Repository record for Bio-implantable microdevices and structures for functional electrical stimulation applications (opens in a new tab)

  12. FASCICULAR PERINEURIUM THICKNESS, SIZE, AND POSITION AFFECT MODEL PREDICTIONS OF NEURAL EXCITATION

    … a section of a human femoral nerve and nerve cuff electrode. These results demonstrate that fascicular selectivity is strongly dependent on the nerve anatomy. Therefore, physiologically accurate computer models are recommended for evaluation and optimization of electrode designs for neural …

    ohiolink Repository record for FASCICULAR PERINEURIUM THICKNESS, SIZE, AND POSITION AFFECT MODEL PREDICTIONS OF NEURAL EXCITATION (opens in a new tab)

  13. Characterization of the high frequency alternating current block in the rat sciatic nerve using cuff electrodes and macro-sieve electrodes

    Tripolar cuff electrodes were designed, fabricated and non-chronically implanted in the sciatic nerve of two-month-old Lewis rats. A proximal constant current stimulus to the nerve was blocked by applying a high frequency sinusoidal signal to the distally placed tripolar cuff electrode. The …

    wustl Repository record for Characterization of the high frequency alternating current block in the rat sciatic nerve using cuff electrodes and macro-sieve electrodes (opens in a new tab)

  14. Toward a wirelessly-powered, fascicle-specific system for peripheral nerve stimulation

    … remain constrained in longevity: intraneural electrodes risk excessive fibrotic encapsulation that can render them ineffective while multi-contact, extraneural cuffs avoid tissue damage but depend on bulky implantable pulse generators and long leads prone to failure. This thesis presents a …

    rice Repository record for Toward a wirelessly-powered, fascicle-specific system for peripheral nerve stimulation (opens in a new tab) Embargoed until 2027-08-01

  15. Reversible Nerve Conduction Block Using Low Frequency Alternating Currents

    … 1 Hz applied through a bipolar extrafascicular electrode. This work follows up on observations made on excised mammalian peripheral nerves and earthworm nerve cords. An in-situ electrophysiology setup was used to assess the LFAC waveform on propagating action potentials (APs) within the cervical …

    iupui Repository record for Reversible Nerve Conduction Block Using Low Frequency Alternating Currents (opens in a new tab)

  16. Stimulation of Peripheral Nerves in M. Mulatta for Somatosensory Psychophysics and VNS Applications

    Cuff-style peripheral nerve interfaces (PNIs) communicate with the central nervous system and offer interesting advantages when compared with other neural interfaces, including brain-computer interfaces (BCIs) and non-cuff PNI designs. PNI development must consider design factors such as volume of …

    wustl Repository record for Stimulation of Peripheral Nerves in M. Mulatta for Somatosensory Psychophysics and VNS Applications (opens in a new tab)

  17. Artificial Control of the Lower Urinary Tract by Sacral Root Stimulation

    … characteristics of bipolar stimulating electrodes. Normal micturition requires co-ordinated bladder contraction and sphincter relaxation. The sacral roots contain large somatic motor fibres supplying the skeletal muscle of the external sphincter mixed in with small autonomic motor fibres …

    glasgow Repository record for Artificial Control of the Lower Urinary Tract by Sacral Root Stimulation (opens in a new tab)

  18. Electromyogram Interference Reduction In Neural Signal Recording Using Simple RC Compensation Circuits

    … of electrical current pulses using implanted electrodes to trigger affected nerves that are damaged due to paralysis. A neural signal recorded using tripolar cuff electrodes is significantly contaminated due to the presence of EMG interference from the surrounding muscles. Conventional neural …

    ucl Repository record for Electromyogram Interference Reduction In Neural Signal Recording Using Simple RC Compensation Circuits (opens in a new tab)

  19. Spatially selective activation of peripheral nerve for neuroprosthetic applications

    The goal of this work was to develop electrodes and stimulation techniques that enable selective electrical excitation of discrete populations of peripheral nerve fibers within a peripheral nerve trunk. A nerve cuff electrode containing 12 individually addressable electrode contacts was tested in …

    ohiolink Repository record for Spatially selective activation of peripheral nerve for neuroprosthetic applications (opens in a new tab)

  20. SELECTIVE STIMULATION AND RECORDING OF THE CANINE HYPOGLOSSAL NERVE FOR THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA

    … control therapeutic stimulation, a single nerve cuff electrode is presented as means to achieving these objectives. To this end, we first investigated the ability of the multi-contact flat-interface-nerve-electrode (FINE) to stimulate selectively the discrete branches of the beagle XII nerve. …

    ohiolink Repository record for SELECTIVE STIMULATION AND RECORDING OF THE CANINE HYPOGLOSSAL NERVE FOR THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA (opens in a new tab)

Page 1 of 2