  1. High frequency method of locating power cable faults

    The Location of a fault in a power cable is by no means a simple task and the techniques used at present warrant further improvement. Many methods of fault location have been devised but each has its particular limitations. Some of these methods include D.C. and A.C. bridge methods, echo-ranging …

    ubc Repository record for High frequency method of locating power cable faults (opens in a new tab) Download PDF for High frequency method of locating power cable faults (opens in a new tab)

  2. Fault location and characterization in AC and DC power systems

    … characterization and overall management of faults in conventional AC distribution systems as well as isolated MVDC power systems. The primary focus in AC distributions systems is on identifying and locating underground cable faults using voltage and current waveforms as the input data. Cable …

    texas Repository record for Fault location and characterization in AC and DC power systems (opens in a new tab)

  3. SUBMARINE CABLES AND CHINESE GRAY ZONE OPERATIONS: ASSESSING ALLEGED SABOTAGE IN THE TAIWAN STRAIT AND BALTIC SEA

    This thesis analyzes the threat of submarine cable sabotage within the context of Chinese gray zone operations, focusing on the Taiwan Strait and the Baltic Sea. Through a comprehensive literature review, case studies, and examination of recent cable fault data, the study addresses whether China …

    nps Repository record for SUBMARINE CABLES AND CHINESE GRAY ZONE OPERATIONS: ASSESSING ALLEGED SABOTAGE IN THE TAIWAN STRAIT AND BALTIC SEA (opens in a new tab)

  4. Fault detection on power cables based on ultrasound images and fourth-order cumulants

    … companies have been inspecting underground power cables in a time consuming and destructive way. The current methodology used by Manitoba Hydro, is to remove the conductive material in the center of the cable, cutting the cable into wafers leaving behind the insulating polymer material known as …

    manitoba Repository record for Fault detection on power cables based on ultrasound images and fourth-order cumulants (opens in a new tab)

  5. Cable Health Monitoring System Built Into Power Converter Using Time Domain Reflectometry

    Aging cables are a critical reliability concern for many electrical systems. Cables run over long distances, are often exposed to harsh environments and are intended to work for several decades. Cable faults can be a serious problem because cables are usually hard to repair or replace. Condition …

    south-carolina Repository record for Cable Health Monitoring System Built Into Power Converter Using Time Domain Reflectometry (opens in a new tab)

  6. Efficient Fault Location and Characterization in Cable Networks with Known and Unknown Topologies

    … lines, emphasizing the importance of cable network reliability in critical industries like telecommunications, automotive, and aerospace. Cable faults are classified into hard and soft faults, both of which can lead to significant safety risks and financial losses. Effective fault …

    qucosa-diss

  7. Design and Control of Series Resonant Converters for DC Current Power Distribution Applications

    … for its low cost and robustness against cable faults. Design and control of dc power distribution systems for different applications is an emerging research area with complex technical challenges. This dissertation solves the technical challenges in analysis, design, modeling, control and …

    utahstate Repository record for Design and Control of Series Resonant Converters for DC Current Power Distribution Applications (opens in a new tab)

  8. The echo ranger : a fault locator for power cables

    The location of faults in low-attenuation coaxial cables and open-wire lines by the use of the echo-ranging techniques of radar prompted this investigation of a method to accurately locate faults in underground power cables. As the propagation-velocity of disturbances on a smooth line or cable is …

    ubc Repository record for The echo ranger : a fault locator for power cables (opens in a new tab) Download PDF for The echo ranger : a fault locator for power cables (opens in a new tab)

  9. Location of faults in power cables by fault-generated surges

    … satisfactory method for locating high-impedance faults in underground cables. Most methods of locating faults require that the fault-impedance be reduced to a low value before the measurement can be made. After a careful investigation of the available literature, it was decided that the most …

    ubc Repository record for Location of faults in power cables by fault-generated surges (opens in a new tab) Download PDF for Location of faults in power cables by fault-generated surges (opens in a new tab)

  10. Design and analysis of secure offshore wind farms

    … the effects of power imbalance during ac network faults for permanent magnet synchronous generator (PMSG) based wind energy conversion systems (WECSs), are comparatively analysed based on performance, economic and practical metrics. Based on a qualitative review of technically viable designs, this …

    strathclyde Repository record for Design and analysis of secure offshore wind farms (opens in a new tab)

  11. Applications of Electromagnetic Principles in the Design and Development of Proximity Wireless Sensors

    … in the VHF-UHF bands in order to detect cable faults. Greater than 3:1 transmission bandwidth (100-300 MHz) is obtained with a cylindrical launcher on square orthogonal ground plane while with a CSW launcher more than an octave (100-240 MHz) bandwidth is achieved. Open circuit faults are …

    south-carolina Repository record for Applications of Electromagnetic Principles in the Design and Development of Proximity Wireless Sensors (opens in a new tab)

  12. Development of a Data-Driven Approach for Permanent Fault Location in Underground Power Cables

    … or failure of specific components such as lines, cables, or individual equipment. In response to these faults, protective devices isolate the affected areas from the network. However, identifying the exact location of the fault can be a time-consuming process. Operators rely on their expertise and …

    sask Repository record for Development of a Data-Driven Approach for Permanent Fault Location in Underground Power Cables (opens in a new tab)

  13. Grasp-sensitive surfaces

    … a technique traditionally used for inspecting cable faults, for touch and grasp sensing. TDRtouch is able to locate touches along a wire, allowing designers to rapidly prototype and implement modular, extremely thin, and flexible grasp-sensitive surfaces. I summarize how these technologies …

    lmu-germany Repository record for Grasp-sensitive surfaces (opens in a new tab)

  14. Zaměřování kabelových poruch a trasování kabelů

    Bakalářská práce se zaměřuje na problematiku trasování kabelů uložených v zemi. Určení jejich hloubky. Předměření místa poruch na kabelech a určení jejich přesného místa. Dává přehled o různých metodách trasování a zaměření různých typů poruch a volby nejvhodnější metody k jejich lokalizaci. …

    brno-tech Repository record for Zaměřování kabelových poruch a trasování kabelů (opens in a new tab)