The Biomechanical Contribution of the Free Floating Ribs: A Pilot Study
Human cadaveric spine testing is done to provide more knowledge for clinicians in understanding living patients and to validate surgical procedures. There are many limitations to cadaveric testing, whether it be equipment or physiological condition of the specimen. Clinically, floating ribs have …
-
Finite Element Analysis of Transverse Medial Malleolar Fracture Fixation
… new fixation device, the Medial Malleolar Sled™. Cadaveric testing assessed the performance of the two constructs in both tension and torsion. Following experimentation, the cadaveric study was modeled in SolidWorks and analyzed via FEA to validate the model against the experimental results. …
-
MECHANICAL STRUCTURES RESISTING ANTERIOR INSTABILITY IN A COMPUTATIONAL GLENOHUMERAL JOINT MODEL
… results from the model to the results of a cadaveric experiment in which the relative contribution of muscles and ligaments to anterior joint stability was examined. The results showed the subscapularis to be critical to stabilization in both neutral and external rotations, the biceps …
-
Design and Analysis of a Compliant Mechanism Spinal Implant
… structures. This combined model is confirmed by cadaveric testing. A stress analysis of the implant for combined loading conditions is also presented. This work introduces and provides a foundation for the FlexSuRe™ spinal implant.
-
Spinal Implant with Customized and Non-Linear Stiffness
… physical prototypes both on a tensile tester and cadaveric testing on an in-house spine tester. Testing showed the inserts are capable of creating a non-linear force-deflection curve and it was observed that the device provided increased stiffness to a spinal segment in flexion-extension and …
-
Multi-scale Modeling of the Lumbar Spine During Manual Material Lifting Tasks
… are involved. Although in vivo studies, cadaveric testing, musculoskeletal modeling, and finite element analysis have all been used to study spine biomechanics, each method has limitations when used alone. This dissertation presents the first application of a multi-scale modeling …
-
Computational modeling of the lower cervical spine: facet cartilage distribution and disc replacement
… in order to establish model convergence, and cadaveric testing was undertaken to validate model predictions. The validated model was altered to include a disc replacement prosthesis at the C4/C5 level. The effect of disc-replacement on range of motion, antero-posterior load distribution, total …
-
Biomechanical and Finite Element Analyses of Alternative Cements for use in Vertebral Kyphoplasty
… biomechanical compression properties to PMMA via cadaveric experimentation and finite element modeling. Cadaveric experiments were carried out to investigate the failure loads of individual osteoporotic thoracolumbar vertebrae. Fractures were artificially created and specimens were restored with …
-
Validation of immature ovine bone models using digital image correlation
… to ethical complexities regarding experimental testing on paediatric cadavers. A recently validated technique for adults using CT-based finite element analysis (FEA), has the potential to provide a deeper understanding of immature bone fracture mechanism without the need of extensive paediatric …
-
Biomechanical Evaluation of Posterior Dynamic Stabilization Systems in Lumbar Spine
… minimal effects on the adjacent levels. In vitro cadaveric testing was conducted on seven harvested sheep spines using established protocols. Axient was implanted in the spines 3 months prior to sacrificing. Main aim of this testing is to see if the performance is altered by the presence of …
-
How hand placement during upper-extremity weight bearing tasks may reduce the risk of chronic elbow disorders in young female acrobatic athletes
… and survey, 2) biomechanical analysis, and 3) cadaveric testing. Fifty-three female gymnasts participated in this study, 20 subjects participated in both the first and second aim. Three post-mortem human surrogates (PMHS) were used for aim three. Anthropometry, range of motion, and elbow …
-
Effect of Patellar Component Thickness on Patellar Kinematics and Patellofemoral Joint Function Following Total Knee Replacement
… patellofemoral joint function utilizing in-vitro cadaveric testing. Within the first section, a 3D computational finite element (FE) model was developed based on the Stanmore knee joint simulator outputs and experimentally validated to optimize the tibiofemoral rotational alignment for appropriate …
-
Characterizing the Porcine Knee as a Biomechanical Surrogate Model of the Human Knee to Study the Anterior Cruciate Ligament
… the rate of force loss during long-term cyclic testing of the native ACL knee in all degrees-of-freedom (DOFs). However, all grafted knees failed to match the initial forces in other DOFs, and each altered the load sharing of primary and secondary contributions. Additionally, all grafted knees …
-
Establishing Design Criteria for Anterior Cruciate Ligament Reconstruction
… directly in human patients in vivo, in vitro testing can serve as an alternative as long as the following conditions are met: 1) Loads are measured in 6 degrees-of-freedom (DOFs); 2) Loads are measured during activities of daily living (ADLs); 3) Loads are measured within a realistic …
-
Research into the Design and Validation of an Innovative Intraoperative Load Sensor for Total Knee Replacements through Experimental and Cadaveric Investigations
… use of the sensors. This included laboratory testing to investigate the performance of the AI in predicting the load and location of the contact force. Accuracy testing uncovered an average accuracy of about 90% for the Zimmer Specific sensor and about 88% for the Ring sensor when predicting …
-
Design and Testing of a Novel Fusion Construct for Atlantoaxial Instability
… constructs was examined through biomechanical cadaveric testing. The results of this study showed that constructs that used C2 translaminar screws were significantly more stable than existing constructs that used C2 translaminar screws. Additionally, novel constructs that used C2 pedicles …
-
Dynamic, multiscale assessment of lumbar functional spinal unit biomechanics during physiologic motion
… information throughout the motion. Under cadaveric testing, the DCV revealed the greatest compliance during low-moment flexion and the lowest during axial rotation, with axial rotation exhibiting the largest offaxis motion. Additionally, the Kemp’s test, a clinically relevant multiplanar …
-
Six Degrees of Freedom: Kinematics of the Healthy Ankle Syndesmosis Joint
… for more realistic loading conditions of cadaveric testing various fixation devices, serve as design parameters for new device design, set a gold standard for normal range of motion (ROM) in rehabilitation, and ultimately improve diagnostic and treatment modalities for syndesmotic injury. …
-
Experimental Evaluation and Comparison of Football-Related Head Impacts Among Ovine, Human, and Hybrid III Headforms
… risks to athlete health. While current helmet testing standards rely heavily on the Hybrid III surrogate headform to evaluate protective performance, these surrogate models lack anatomical accuracy and exclude the presence of a brain component, limiting their ability to capture the true …
-
Multi-Modal Computer- and Robot-Assisted Navigation in Spinal Surgery
… ratio of 22.9 dB against ground-truth CT in cadaveric testing. Chapter 5 presents a robotic ultrasound system for radiation-free bone surface reconstruction, combining force-controlled scanning with a deep-learning segmentation pipeline. The system achieved mean surface errors of 1.28 mm in …