Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 67 for “"Cadaveric Specimens"”.

  1. Detection of serological markers of infection in cadaveric specimens

    … materials from deceased donors. The quality of cadaveric specimens for infectious disease testing may differ from living donor, potentially affecting serological screening results. The present study aimed to identify changes in venous blood samples of cadaver donors that may influence the …

    unsw Repository record for Detection of serological markers of infection in cadaveric specimens (opens in a new tab)

  2. Innervation of the Posterior Aspect of the Sacroiliac Joint: An Anatomical Basis for Diagnostic Blocks and Radiofrequency Ablation Techniques for Sacroiliac Joint Pain

    … dissection, digitization and 3D modeling of cadaveric specimens (n=25 SIJs). The S1-S3 ± L5/S4 LBs united to form a fine nerve plexus, the posterior sacral network (PSN), which consistently coursed over the lateral sacral crest between the first and third transverse sacral tubercles (TSTs). …

    toronto-retro Repository record for Innervation of the Posterior Aspect of the Sacroiliac Joint: An Anatomical Basis for Diagnostic Blocks and Radiofrequency Ablation Techniques for Sacroiliac Joint Pain (opens in a new tab)

  3. Material Characterization of Thermoplastic Polyurethane (TPU) and Thermoplastic Elastomers (TPE) for Development of 3D-Printed Surrogate Organs for Medical Training

    Cadaveric specimens are a necessary, albeit limited, resource for training medical students on basic surgical skills. The availability of surrogate 3D-printed organs would readily allow access to resources that could reduce or potentially eliminate the need for cadaveric specimens or, at a minimum, …

    wvu Repository record for Material Characterization of Thermoplastic Polyurethane (TPU) and Thermoplastic Elastomers (TPE) for Development of 3D-Printed Surrogate Organs for Medical Training (opens in a new tab)

  4. Anterolateral Versus Medial Plating for Comminuted Intra Articular Distal Tibia Fractures: A Biomechanical Assessment

    … effectiveness of these plates using cadaveric specimens. Eight pairs of cadaveric specimens were anatomically aligned and potted proximally. A typical fracture pattern was created in each specimen and then one from each pair treated with an anterolateral and the other with a medial …

    mcmaster Repository record for Anterolateral Versus Medial Plating for Comminuted Intra Articular Distal Tibia Fractures: A Biomechanical Assessment (opens in a new tab)

  5. A Combined Experimental-Computational Method to Generate Reliable Subject Specific Models of the Knee's Ligamentous Constraint

    … laxity after total knee replacement in eight cadaveric specimens. A computational model of ligament constraint was developed to complement the knee laxity data collected during the experimental protocol. A sensitivity study performed on the model identified the most critical ligament …

    ku Repository record for A Combined Experimental-Computational Method to Generate Reliable Subject Specific Models of the Knee's Ligamentous Constraint (opens in a new tab)

  6. Arciero vs. LaPrade: A Biomechanical Study Comparison of Two Techniques for Knee Posterolateral Corner Reconstruction

    … PLC. 10 paired fresh frozen lower extremity cadaveric specimens were used for experimentation. One limb from each pair was reconstructed using the LaPrade technique and the other with the Arciero technique using the Achilles tendon as graft material. A custom made testing fixture was created …

    unm Repository record for Arciero vs. LaPrade: A Biomechanical Study Comparison of Two Techniques for Knee Posterolateral Corner Reconstruction (opens in a new tab)

  7. Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy

    … induce a flexible flatfoot on neutrally aligned cadaveric specimens. Previous research has shown the ligaments most involved in supporting the medial arch were the superomedial and inferomedial calcaneonavicular (spring), talocalcaneal interosseous, plantar naviculocuneiform, plantar first …

    washington Repository record for Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy (opens in a new tab)

  8. Learning anatomy at university : effectiveness, issues and implications for the future education of doctors

    … touch-mediated perception from examining human cadaveric specimens and is the preferred approach to learning anatomy as it enables an understanding of the three-dimensional form. Anatomy learning occurs in three stages and the approach adopted reflects different levels of engagement in these …

    soton Download PDF for Learning anatomy at university : effectiveness, issues and implications for the future education of doctors (opens in a new tab)

  9. Ο ΟΣΦΥΙΚΟΣ ΣΠΟΝΔΥΛΙΚΟΣ ΣΩΛΗΝΑΣ: ΠΑΘΟΛΟΓΟΑΝΑΤΟΜΙΚΗ ΚΑΙ ΚΛΙΝΙΚΟΕΡΓΑΣΤΗΡΙΑΚΗ ΜΕΛΕΤΗ-ΣΥΣΧΕΤΙΣΗ ΕΥΡΗΜΑΤΩΝ

    … CANAL AT VARIOUS LEVELS WERE MEASURED IN 37 CADAVERIC SPECIMENS OF THE WHOLE LUMBAR SPINE. THE SAME MEASUREMENTS WERE REPEATED ON CT AND MRI PICTURES OF THE SAME MATERIAL. SATISFACTORY CORRELATION BETWEEN THE MEASUREMENTS OF THE TWO RADIOLOGIC TECHNIQUES WAS FOUND. THE RELIABILITY OF THE CT …

    greece Repository record for Ο ΟΣΦΥΙΚΟΣ ΣΠΟΝΔΥΛΙΚΟΣ ΣΩΛΗΝΑΣ: ΠΑΘΟΛΟΓΟΑΝΑΤΟΜΙΚΗ ΚΑΙ ΚΛΙΝΙΚΟΕΡΓΑΣΤΗΡΙΑΚΗ ΜΕΛΕΤΗ-ΣΥΣΧΕΤΙΣΗ ΕΥΡΗΜΑΤΩΝ (opens in a new tab)

  10. Transverse Plane Rotational Misalignment of Ankle Arthrodesis and Arthroplasty in Cadaveric Gait Simulation

    … to examine misalignment of these procedures in cadaveric gait simulation. Using cadaveric specimens in orthopaedics and biomechanics allows for novel concepts or evaluations of procedures to be performed without the potential harm to a patient. A robotic gait simulator was used to simulate …

    washington Repository record for Transverse Plane Rotational Misalignment of Ankle Arthrodesis and Arthroplasty in Cadaveric Gait Simulation (opens in a new tab)

  11. DEVELOPMENT OF WRIST BIOMECHANICAL MODEL INSPIRED BY ORB-WEB ARCHITECTURE [WEB.AM]

    … of a wrist biomechanical assessment tool. Five cadaveric specimens underwent CT scanning at 11 positions (40° wrist extension to 40° flexion, 5° radial to 20° ulnar deviation). Custom Matlab program were developed to analyze the reconstructed models' kinematic networks. The virtual network …

    nus Repository record for DEVELOPMENT OF WRIST BIOMECHANICAL MODEL INSPIRED BY ORB-WEB ARCHITECTURE [WEB.AM] (opens in a new tab) Download file for DEVELOPMENT OF WRIST BIOMECHANICAL MODEL INSPIRED BY ORB-WEB ARCHITECTURE [WEB.AM] (opens in a new tab)

  12. A Study of the Impact Response of Discrete Regions of the Human Cadaver Brain

    … system was used to capture brain motion for two cadaveric specimens at 7,500 fps. Displacement of brain structures was determined for 7 impacts on each specimen. Motion trends were region dependent, with some regions exhibiting multi-modal displacement. Displacement of discrete structures …

    carleton Repository record for A Study of the Impact Response of Discrete Regions of the Human Cadaver Brain (opens in a new tab)

  13. Refinement and validation of MRI-based models for joint contact mechanics

    … MRI-based modeling technique was tested using 5 cadaveric specimens. It was found the MRI-based models and the direct measurement from MR image sets showed similar results for contact area. The Tekscan and MRI-based model technique showed similar measures of contact force, and the Pressurex and …

    ku Repository record for Refinement and validation of MRI-based models for joint contact mechanics (opens in a new tab)

  14. Comparison of a novel surgical implant with the volar locking plate for the treatment of distal radius fractures: a mechanical study

    … for rods were prototyped and tested on cadaveric specimens to obtain a balance between different number/types of rods, stability and technical ease. A combination of radial and volar rods linked together proximally was found to best meet the criteria. Ideally, the spheres should be …

    sask Repository record for Comparison of a novel surgical implant with the volar locking plate for the treatment of distal radius fractures: a mechanical study (opens in a new tab)

  15. Novel Educational Tools to Understand the Cardiac Device Delivery Pathways

    … Methods Datasets were collected from human cadaveric specimens, isolated hearts, and clinical images. These datasets were analyzed for the cardiac device delivery pathways and the device-tissue interactions in both static and dynamic settings. Results Generated instructional videos and 3D …

    umn Repository record for Novel Educational Tools to Understand the Cardiac Device Delivery Pathways (opens in a new tab)

  16. Development and Biomechanical Testing of an Artificial Vertebral Body

    … loading and compared to a group of human cadaveric T9 vertebrae. Solid models made from plaster lacked the viscoelastic component present in the human cadavers. Rigid foaming polyurethane responded with a mechanical behavior more consistent with the cadaveric specimens.

    marquette Repository record for Development and Biomechanical Testing of an Artificial Vertebral Body (opens in a new tab)

  17. Automated Performance Assessment of Virtual Temporal Bone Dissection

    … with the traditional way of learning, i.e., cadaveric specimens. However, without an automatic feedback mechanism, an expert's presence is required to assess the performance, placing a heavy burden on their time. This investigation focuses on automating the performance evaluation obviating …

    calgary Repository record for Automated Performance Assessment of Virtual Temporal Bone Dissection (opens in a new tab)

  18. Intra-Tendinous Arterial Supply of the Gluteus Medius and Minimus Muscles

    … barium sulphate was used for the embalmed human cadaveric investigation. Second, ten human cadaveric specimens were used to compare micro-CT angiography with three-dimensional (3-D) images and histological investigations (Haematoxylin and Eosin stain) of the intra-tendinous arterial supply of the …

    anu Repository record for Intra-Tendinous Arterial Supply of the Gluteus Medius and Minimus Muscles (opens in a new tab)

  19. The Design and Validation of a Computational Rigid Body Model of the Elbow.

    … using computed topography (CT) scans of cadaveric donor tissue, as well as the commercially available software package SolidWorks™. The kinematic function of the joint model was then defined through 3D reconstructions of the osteoarticular surfaces and various soft-tissue constraints. The …

    vcu Repository record for The Design and Validation of a Computational Rigid Body Model of the Elbow. (opens in a new tab)

  20. Comprobando la integridad del trayecto pedicular torácico: ¿es valido el uso del palpador pedicular? Técnica en cadáveres

    … pedicle integrity way. Methods: Thoracic pedicle cadaveric specimens were channeled in which randomly were classified as normal (intact) or abnormal (violated). Subsequently four spine surgeons at various levels of expertise, assessed the pedicle way. Studies of agreement were obtained, Kappa …

    rosario Repository record for Comprobando la integridad del trayecto pedicular torácico: ¿es valido el uso del palpador pedicular? Técnica en cadáveres (opens in a new tab)

Page 1 of 4