Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 58 for “"Cadaveric Study"”

  1. Strains of human rotator cuff tendons at various joint positions : a cadaveric study

    … are also significant. The purpose of this study was to detect the bursal-side human rotator cuff strains over a range of clinically relevant joint positions. With the help of Differential Variable Reluctance Transducers , bursal-side rotator cuff strains were analyzed in cadaveric …

    nanyang Repository record for Strains of human rotator cuff tendons at various joint positions : a cadaveric study (opens in a new tab)

  2. Comparing Wear of the Osteoarthritic Temporomandibular Joint and Distal Interphalangeal Joint: A Cadaveric Study

    … affecting multiple joints in an individual. This study aimed to determine whether OA severity and spatial wear patterns are concordant across joints with distinct biomechanics and ossification processes by comparing the temporomandibular joint (TMJ) and the distal interphalangeal joint (DIPJ). …

    creighton Repository record for Comparing Wear of the Osteoarthritic Temporomandibular Joint and Distal Interphalangeal Joint: A Cadaveric Study (opens in a new tab)

  3. Efficacy of common stabilization techniques on protecting the ulnar collateral ligament of the thumb:A cadaveric study

    … are also common. The primary objective of this study was to evaluate the effectiveness of common stabilizationtechniques for the UCL in embalmed and fresh cadaveric specimens. An additional objective of this study was to descriptively and quantitatively analyze the anatomical differences between …

    ohiolink Repository record for Efficacy of common stabilization techniques on protecting the ulnar collateral ligament of the thumb:A cadaveric study (opens in a new tab)

  4. Preoperative Tibial Plateau Leveling Osteotomy Planning Using the Conventional and Common Tangent Methods: A Cadaveric Study

    … angle following rotation of the tibial plateau. Study Design – Cadaveric study. Seven paired canine pelvic limbs. Methods- Radiographs of the stifle were taken at 135° of extension prior to and following rotation of the tibial plateau under load (0N and 30N). The tibial plateau of each limb was …

    vt Repository record for Preoperative Tibial Plateau Leveling Osteotomy Planning Using the Conventional and Common Tangent Methods: A Cadaveric Study (opens in a new tab)

  5. Comparison of Dye Spread in Halstead, Vazirani-Akinosi and Gow-Gates Nerve Block Techniques: A Cadaveric Study

    … staining but not for other techniques. This study aimed to compare the range of dye spread between the traditional Halstead, Vazirani-Akinosi and Gow-Gates techniques. Moreover, we assessed the variation in the location of the mandibular foramen. METHODS. Preliminarily, three fresh-frozen …

    creighton Repository record for Comparison of Dye Spread in Halstead, Vazirani-Akinosi and Gow-Gates Nerve Block Techniques: A Cadaveric Study (opens in a new tab)

  6. Stability of long multiple-rod constructs and dual-rod constructs in the thoracic spine: a biomechanical cadaveric study

    … to a four-rod (multiple-rod) construct (MRC) in cadaveric thoracic spines. Nine intact human cadaveric thoracic spines (T1-T12) were instrumented with either a DRC or MRC, and biomechanical testing was then carried out to compare range of motion (ROM) and stiffness between these two constructs. …

    uwo Repository record for Stability of long multiple-rod constructs and dual-rod constructs in the thoracic spine: a biomechanical cadaveric study (opens in a new tab)

  7. The motion of the anterior cruciate ligament during internal and external rotation of the knee: a cadaveric study

    … have gone unreported. Therefore, the aim of this study was to quantify and compare the movements of a femoral, midpoint, and tibial marker located on the AM and PL bundles of the ACL during 15° of internal and external rotation, in the presence and absence of an anterior force. Significant …

    manitoba Repository record for The motion of the anterior cruciate ligament during internal and external rotation of the knee: a cadaveric study (opens in a new tab)

  8. Anatomy of the lamina terminalis and the cisterna chiasmatica: a cadaveric study at the university teaching hospital Lusaka Zambia.

    … of the LT in a Zambian population. This study was aimed to explore the anatomy of the Lamina Terminalis, the Cisterna Chiasmatica and its neurovascular relationships as seen in a Zambian population and compare with the findings in the literature. This was a descriptive cross-sectional …

    zambia Repository record for Anatomy of the lamina terminalis and the cisterna chiasmatica: a cadaveric study at the university teaching hospital Lusaka Zambia. (opens in a new tab)

  9. A cadaveric study on variations of the cystic artery in the department of pathology, at the university teaching hospitals, Lusaka, Zambia.

    … can lead to death. The objectives of the study were; 1. To establish the origin of the cystic artery. 2. To determine the length of the cystic artery. 3. To establish the course of the cystic artery. 4. To establish the relationship of the cystic artery to the cystic duct. This was a …

    zambia Repository record for A cadaveric study on variations of the cystic artery in the department of pathology, at the university teaching hospitals, Lusaka, Zambia. (opens in a new tab)

  10. Influence of Externally Applied Moments and Loads on Knee Kinematics: A Cadaveric Study of Single- and Multi-Axis Loading of the Knee

    … after ACL injury. The aims of the current study were to evaluate cadaveric knee kinematics to better understand ACL injury modalities.In this study, a total of 18 cadaveric knee specimens (age 44 +/- 8 years, 10 female and 8 male, 10 right and 8 left limbs) were tested under 65 loading …

    ohiolink Repository record for Influence of Externally Applied Moments and Loads on Knee Kinematics: A Cadaveric Study of Single- and Multi-Axis Loading of the Knee (opens in a new tab)

  11. Anatomical and radiological study of the internal branch of the superior laryngeal nerve and its importance for neck surgical approaches: a cadaveric study

    … key structures to avoid harming them. This study used anatomical dissection in formalin-embalmed adult cadavers to expose the ibSLN, marking it afterward with a radiopaque wire and proceeding with X-ray imaging. Then, we analyzed the nerve's path in relation to the vertebral levels and …

    porto Repository record for Anatomical and radiological study of the internal branch of the superior laryngeal nerve and its importance for neck surgical approaches: a cadaveric study (opens in a new tab)

  12. The Bio-Mechanical Development and Kinematic Evaluation of Zone I and Zone II Injuries and their Corresponding Surgical Repair Techniques using an In-Vitro Active Finger Motion Simulator: A Cadaveric Study

    Research development involving large scale joint mechanics and biomechanical adaptations is growing. However, interest in smaller scale joints, such as the fingers, is limited. Thus, the present work describes the enhancement and clinical application of a previously designed in-vitro active finger …

    uwo Repository record for The Bio-Mechanical Development and Kinematic Evaluation of Zone I and Zone II Injuries and their Corresponding Surgical Repair Techniques using an In-Vitro Active Finger Motion Simulator: A Cadaveric Study (opens in a new tab)

  13. Knee Balance Assessment During Cementation Is Detrimental to Initial TKA Tibial Tray Fixation

    … mechanism of aseptic loosening and to perform a cadaveric study on modern commercially available TKA systems to evaluate their ability to mitigate the risks of poor fixation. The results from this study indicate that tibial components with no cement mantle around the cone or keel structure …

    denver Repository record for Knee Balance Assessment During Cementation Is Detrimental to Initial TKA Tibial Tray Fixation (opens in a new tab)

  14. Lower Stiffness Orthopaedic Implants for Hemiarthroplasty

    … below a Young’s modulus of 300 MPa. A cadaveric study was done to compare a high, mid, and ultra-low stiffness material to the native state. It was found that only the ultra- low stiffness material improved contact mechanics. Future hemiarthroplasty implant designs should focus on using …

    uwo Repository record for Lower Stiffness Orthopaedic Implants for Hemiarthroplasty (opens in a new tab)

  15. A Computational Assessment of Lisfranc Injuries and their Surgical Repairs

    … approach or procedures across studies. This study uses a computational biomechanical model validated on a cadaveric study to evaluate factors that impact injury presentation and to compare the different procedures ability to stabilize the Lisfranc joint after an injury. Using SolidWorks® a …

    vcu Repository record for A Computational Assessment of Lisfranc Injuries and their Surgical Repairs (opens in a new tab)

Page 1 of 3