Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 17 of 17 for “"Cadaveric specimen"”
-
Further defining subcutaneous innervation patterns to help reduce sensory deficits following ACL surgery using cadaveric heatmap and exploring ultrasound imaging
… sensory nerves were also explored. In both specimens, all branches of the femoral cutaneous and saphenous nerves were located, dissected, and mapped. In addition, the ability to locate terminal branches of the anterior femoral cutaneous nerve in a cadaveric specimen on ultrasound was …
-
Experimental Evaluation and Comparison of Football-Related Head Impacts Among Ovine, Human, and Hybrid III Headforms
… impact testing of a Hybrid III headform and a cadaveric specimen. Additionally, this fixture preserves natural head-neck articulation and enables realistic evaluation of ovine and cadaveric specimens. Using wireless accelerometer arrays placed in both the skull and brain, this study quantified …
-
A Biomechanical Investigation of Load Sharing at the Distal Forearm
… were designed to measure in vitro loading in cadaveric specimen. The implants were evaluated and found reliable for use in further biomechanical studies. An in vitro study investigated the effect of joint angle and direction of joint motion on loads in the distal radius and ulna during active …
-
The influence of facet joint geometry on lumbar segmental kinematics : an ex-vivo & in-vivo study
… In the ex-vivo set-up, facets of individual cadaveric vertebrae taken from a previous biomechanical. study were digitized using a 3D morphometer and the geometry of the facet joints in respect to the vertebra's local coordinate system was quantified. In the in-vivo set-up, re-recruited …
-
Computationally Efficient Finite Element Models of the Lumbar Spine for the Evaluation of Spine Mechanics and Device Performance
… were reconstructed from CT scans of the cadaveric specimen. Prior to model development, experimental testing was performed on the specimen using a custom multi-axis spine simulator. Collection of kinematic data in response to external loading made tuning of the model stiffness possible. …
-
DESIGN AND DEVELOPMENT OF IN VITRO TOOLS TO ASSESS FIXATION AND MOTION IN THE SPINE
… vitro sacral model. Screws were tested in seven cadaveric sacra and subjected to stair-cased cyclic flexion extension loading to simulate the clinical loading scenario. The hollow screw was less resistant to loosening compared to the solid screw in this model. In the second part of this thesis, …
-
DESIGN AND DEVELOPMENT OF IN VITRO TOOLS TO ASSESS FIXATION AND MOTION IN THE SPINE
… vitro sacral model. Screws were tested in seven cadaveric sacra and subjected to stair-cased cyclic flexion- extension loading to simulate the clinical loading scenario. The hollow screw was less resistant to loosening compared to the solid screw in this model. In the second part of this thesis, …
-
Computational Modeling and Analysis of Complex Muscle Architecture
… challenging to accurately assess them. Previous cadaveric approaches only take into account limited portions of architecture. On the other hand, conventional radiological approaches, such as ultrasonography and MRI, examine two-dimensional projected images. Neither of these approaches provides a …
-
Development of an Active Infection Monitoring Knee Spacer for Two-Stage Revision
… radio frequency penetration evaluation, a cadaveric loading study to confirm durability, a micro CT evaluation of the sensor’s impact on implant integrity and a comparison of internal vs external joint temperature during joint movement. The results of this work describe a largely effective …
-
A Novel Method for Quantifying Uncertainty in the Unified Envelope of Constraint in the Passive Knee Joint
… performed manual laxity evaluations on one cadaveric specimen. Data from these evaluations were sequentially downsampled and used to create many slightly different UEs. The variance of these UEs at each point were combined with a general measure of variance, found by calculating the variance …
-
Experimental and Numerical Assessments of Injury Criteria for Short-Duration, High-Force Impact Loading of the Tibia
… of the tibia (i.e., lower leg bone) using both cadaveric specimens and test surrogates. Surrogates that were considered for injury prediction were synthetic bones, ATDs, and finite element models. Experimental testing was accomplished through the development of a pneumatic testing apparatus …
-
Advancing Thoracic Spine Biomechanical Research
… test machine for rigidity ranges that represent cadaveric specimen rigidities present in the spine. Cervical, thoracic, and lumbar spine specimens were modeled with synthetic rubber that represented the breadth of rigidities, and testing was conducted in bending and axial rotation. The maximum …
-
A novel method of cadaveric data acquisition from a dissection of the male lower limb using the Perceptron ScanWorks® V5 scanner
… Given the limited time now available for cadaveric dissection in medical training, future rectification of these deficits is becoming heavily dependent on supplementation from virtual anatomical training tools. In light of this, many attempts have been made to acquire cadaveric data for …
-
Validating Internal Density Calibration in The Proximal Humerus to Estimate Bone Stiffness Using Finite Element Analysis for Stemless Shoulder Arthroplasty
… vBMD and apparent stiffness. Non-pathologic cadaveric single-energy CT images containing a dipotassium phosphate (K2HPO4) phantom were used to analyze a 10 mm thick volume of interest (VOI) directly below the anatomic neck. Phantom and internal density calibration was performed on each …
-
Biomechanical Evaluation of Disc Annular Repair Technology in Human Lumbar Spine
… repair device in an in-vitro in the human cadaveric lumbar spine. The test criterion was to evaluate implant migration during complex cyclic loading, study its effects on the range of motion of the functional spinal segment and intradiscal pressures. The overall stability of the device is …
-
Modelling & Experimental Investigations Of Distal Radius Surface Strain Distributions During Off-Axis Loading
… strain distributions during off-axis loading of cadaveric wrist specimens to failure. Two studies were conducted to evaluate the loading characteristics of the distal radius under off-axis conditions. First a 2D ANSYS Finite Element model was created from the sagittal segmented data of one …
-
Multi-Axial Motion and Intervertebral Kinematics of the Cervical Spine: Implications for those with Neck Pain
… was utilized for aims 1 and 2. Aim 1 utilized a cadaveric specimen with implanted tantalum beads for RSA as the gold standard of comparison to a 2D/3D shape-matching algorithm at both the cervical and lumbar spine. Additionally, primary sources of RSA error were examined using a Monte Carlo …