  1. Using Noninvasive Calibrated Cuff Plethysmography to Observe the Effects of Diabetes on Arterial Compliance

    … and more specifically endothelial dysfunction. A calibrated cuff plethysmography device is a promising solution to measure endothelial function by specifically looking at the arterial compliance of certain blood vessels. IN this study, a calibrated cuff plethysmography device was used to test for …

    calpoly Repository record for Using Noninvasive Calibrated Cuff Plethysmography to Observe the Effects of Diabetes on Arterial Compliance (opens in a new tab)

  2. Using Noninvasive Calibrated Cuff Plethysmography to Observe the Effects of Lifestyle Habits on Arterial Compliance

    … This study revolves around a non-invasive calibrated cuff device that uses the principles of segmental plethysmography and oscilliometry to measure arterial compliance of baseline and induced hyperemic conditions in human subjects to determine how well arteries vasodilate in response to …

    calpoly Repository record for Using Noninvasive Calibrated Cuff Plethysmography to Observe the Effects of Lifestyle Habits on Arterial Compliance (opens in a new tab)

  3. USING NONINVASIVE CALIBRATED CUFF PLETHYSMOGRAPHY TO OBSERVE THE EFFECTS OF COLD-WATER IMMERSION ON ARTERIAL COMPLIANCE

    … of ice plunging on cardiovascular health. Calibrated cuff plethysmography is a promising method of reflecting on endothelial function by measuring arterial compliance of select blood vessels. In this study, a calibrated cuff plethysmography device was built and tested for efficiency as it …

    calpoly Repository record for USING NONINVASIVE CALIBRATED CUFF PLETHYSMOGRAPHY TO OBSERVE THE EFFECTS OF COLD-WATER IMMERSION ON ARTERIAL COMPLIANCE (opens in a new tab)

  4. Effects Of Beet Supplements On Cardiovascular Response Using A Noninvasive Blood Pressure Cuff

    A Calibrated Cuff Plethysmography device was built, tested for verification, and used to experiment on human subjects to measure the cardiovascular response of consuming a beet supplement, specifically looking at arterial compliance and pressure-area curves. Each subject was tested four times. A …

    calpoly Repository record for Effects Of Beet Supplements On Cardiovascular Response Using A Noninvasive Blood Pressure Cuff (opens in a new tab)