Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 355 for “"Calibration methods"”.

  1. Rotorcraft Blade Angle Calibration Methods

    … and efficient flight. In this study, a current calibration method focusing on the pitch, flap, and lead-lag blade angles is analyzed and found to have larger than acceptable error associated with the sensor calibrations. A literature review is conducted which reveals four novel methods that can …

    odu Repository record for Rotorcraft Blade Angle Calibration Methods (opens in a new tab)

  2. A comparison of rater calibration methods

    Thesis (Ph. D.)--Michigan State University. Department of Measurement Evaluation and Research Design, 1990

    msu Repository record for A comparison of rater calibration methods (opens in a new tab)

  3. Calibration Methods for Head-Tracked 3D Displays

    … 3D effect, but even small inaccuracies in the calibration of the participant’s viewpoint to the display can disrupt the 3D illusion. We propose a novel interactive procedure for a participant to easily and accurately calibrate a head-tracked display by visually aligning patterns across a …

    sask Repository record for Calibration Methods for Head-Tracked 3D Displays (opens in a new tab)

  4. Advanced calibration methods for nonlinear multisensor systems

    This thesis reports on advanced calibration methods for nonlinear multisensor systems (MSSs). The application of half-blind calibration (HBC) is ex- tended to nonlinear MSSs, and a probabilistic calibration method based on Bayesian inference is investigated. The effectiveness of the methods is …

    freiburg-diss Repository record for Advanced calibration methods for nonlinear multisensor systems (opens in a new tab)

  5. Comparison of unconstrained and constrained calibration methods.

    … to the accuracy attained by an unconstrained calibration using computer simulated measurements. A kinematic model is established for each configuration using the Denavit- Hartenberg methodology. The kinematic equations are formulated and are used in the computer simulated calibration to …

    nps Repository record for Comparison of unconstrained and constrained calibration methods. (opens in a new tab)

  6. Analog self-calibration methods for pipelined ADC

    … in pipelined ADC. In this thesis, two methods for self-calibrating pipelined ADC's in analog domain are presented. In one method, each of these non-idealities in a pipeline stage is corrected to give close to ideal transfer characteristic. Techniques for calibrating comparator offset, …

    iastate Repository record for Analog self-calibration methods for pipelined ADC (opens in a new tab)

  7. Advancing atmospheric humidity measurements on Mars through improved calibration methods

    … Perseverance rovers. It presents new laboratory calibrations and an improved calibration methodology in order to obtain near-surface relative humidity measurements that are more accurate than previously possible. The flight calibration of the MEDA HS humidity sensor onboard the Perseverance rover …

    aalto Repository record for Advancing atmospheric humidity measurements on Mars through improved calibration methods (opens in a new tab)

  8. In Vivo Calibration Methods of SPME and Application to Pharmacokinetic Studies

    … there are two types of pre-equilibrium kinetic calibration that have been applied to in vivo SPME: on-fibre standardization and dominant pre-equilibrium desorption. Both of these techniques have their own advantages and disadvantages. To address the limitations presented by these two techniques, …

    waterloo Repository record for In Vivo Calibration Methods of SPME and Application to Pharmacokinetic Studies (opens in a new tab)

  9. Highly Efficient Spectral Calibration Methods for Swept-Source Optical Coherence Tomography

    … "k", not time. To solve this problem a "calibration" step needs to be performed; in this process, the acquired interferogram signal is linearized into k-space. The process usually involves estimating the phase-frequency change profile of the SS-OCT system via Hilbert transformation, …

    tamu Repository record for Highly Efficient Spectral Calibration Methods for Swept-Source Optical Coherence Tomography (opens in a new tab)

  10. Performance Evaluation for Full 3D Projector Calibration Methods in Spatial Augmented Reality

    … of SAR, we developed a projector-camera calibration approach using infrared markers. However, the projection suffers severe distortion due to the lack of depth information in the projection space. For this research, we propose to develop a RGBD sensor - projector system to replace our …

    temple Repository record for Performance Evaluation for Full 3D Projector Calibration Methods in Spatial Augmented Reality (opens in a new tab)

  11. IMPACT OF ELA CALIBRATION METHODS ON BUILDING ENERGY MODEL FIDELITY AND FITNESS

    … but the literature shows that their calibration and validation is still unsatisfactory. In fact, calibration and validation of BPS models is still an important subject of study in our quest to improve the fidelity of simulation-based predictions in various applications. The high level …

    gatech Repository record for IMPACT OF ELA CALIBRATION METHODS ON BUILDING ENERGY MODEL FIDELITY AND FITNESS (opens in a new tab)

  12. Development of detectors and calibration methods for spectral irradiance and radiometric temperature measurements

    … focused on the development of new detectors, calibration methods and their applications in optical radiometry. A new photodetector, which is based on three GaAsP Schottky-barrier photodiodes, has been introduced. The spectral properties of the GaAsP trap detector have been studied in the …

    aalto Repository record for Development of detectors and calibration methods for spectral irradiance and radiometric temperature measurements (opens in a new tab)

  13. Development of on-wafer calibration methods and planar Schottky diode characterisation at THz frequencies

    This thesis focuses on development of on-wafer calibration methods for S-parameter measurements and Schottky diode characterisation at millimeter wave and terahertz frequencies. The radio frequency characteristics of components at the wafer level are obtained using on-wafer S-parameter measurements …

    aalto Repository record for Development of on-wafer calibration methods and planar Schottky diode characterisation at THz frequencies (opens in a new tab)

  14. An Implantable Low Pressure, Low Drift, Dual BioPressure Sensor and In-Vivo Calibration Methods Thereof

    … strain sensing device, with a novel in-vivo calibration system and method thereof, for application to long-term implantable ICP sensing.</p>

    utk-theses Repository record for An Implantable Low Pressure, Low Drift, Dual BioPressure Sensor and In-Vivo Calibration Methods Thereof (opens in a new tab)

Page 1 of 18