Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 62 for “"Calibration strategy"”

  1. AN AUTOMATIC CALIBRATION STRATEGY FOR 3D FE BRIDGE MODELS

    … retrofit schemes. This thesis will focus on the calibration strategy for FE bridge models. Model calibration starts from a nominal bridge model. Experimental data which was processed from a bridge field test is used for calibration reference. The nominal bridge was built according to the bridge …

    ohiolink Repository record for AN AUTOMATIC CALIBRATION STRATEGY FOR 3D FE BRIDGE MODELS (opens in a new tab)

  2. Airborne Particulate Matter Sample Analysis Using Dried-Droplet Standards and Laser Ablation Inductively Coupled Plasma Mass Spectrometry

    … analysis is performed together with adequate calibration in order to provide quantitative data. In this work, we developed a calibration strategy for the analysis of airborne particles collected on cellulose filters. The calibration was performed using dried droplets of multi-element standard …

    chalmers Repository record for Airborne Particulate Matter Sample Analysis Using Dried-Droplet Standards and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (opens in a new tab)

  3. Non-transportable Statistical Calibration of a Network of Low-Cost NO2 Sensors

    … from these sensors can be unstable and requires calibration and validation, typically using measurements from regulatory-grade sensors as a reference. The availability of such data is often limited owing to the high deployment cost. The sensor-specific biases between each low-cost unit further …

    jhu Repository record for Non-transportable Statistical Calibration of a Network of Low-Cost NO2 Sensors (opens in a new tab)

  4. Development of a Practical Lu-177 Activity Calibration Protocol for Clinical Nuclear Medicine: Dosimetric Impact Analysis and Implementation Tools

    … This study presents a practical clinical calibration strategy under real-world constraints for Lu-177 activity measurement using standard nuclear medicine instrumentation. A vial-based approach was implemented using a well-type ionization chamber (Capintec CRC-15R) to evaluate measurement …

    vcu Repository record for Development of a Practical Lu-177 Activity Calibration Protocol for Clinical Nuclear Medicine: Dosimetric Impact Analysis and Implementation Tools (opens in a new tab)

  5. Structural Condition Assessment of Steel Stringer Highway Bridges

    … Element Modeling of Bridges: To quantify the calibration process, static response based objective functions are carefully developed based on two powerful condition indices: Bridge Girder Condition Indicators (BGCIs) and Unit Influence Lines (UILs). Using an existing calibration strategy, a …

    ohiolink Repository record for Structural Condition Assessment of Steel Stringer Highway Bridges (opens in a new tab)

  6. Microwave interferometric radiometry with satellite formation flight for earth observation

    … thrusters to achieve this precision, and 4) new calibration strategy for inter-satellite baselines.<br/><br/>The expected performance of these systems are characterised using two simulators developed in this project: the formation flight synthetic aperture interferometric radiometer performance …

    soton Repository record for Microwave interferometric radiometry with satellite formation flight for earth observation (opens in a new tab)

  7. Nonlocal modelling of fracture in heterogeneous quasi-brittle materials

    … to take into account boundaries. Furthermore, a strategy to calibrate the nonlocal radius is developed. It is also required to demonstrate that the nonlocal models can describe fracture in reinforced concrete structures mesh-independently. The performance of different nonlocal models in analysing …

    glasgow Repository record for Nonlocal modelling of fracture in heterogeneous quasi-brittle materials (opens in a new tab)

  8. Essays on Unemployment Volatility

    … `hiring surplus'. We investigate a widely used calibration strategy in the literature and argue that it is a key factor in generating large unemployment volatility. In the fourth chapter, we reassess the following arguments on the unemployment volatility puzzle: strategic wage bargaining; large …

    bath Repository record for Essays on Unemployment Volatility (opens in a new tab)

  9. NON-TRADITIONAL CALIBRATION STRATEGIES FOR APPLICATIONS IN ATOMIC SPECTROMETRY

    Calibration is one of the most important steps of any analytical chemistry procedure. The selection of an appropriate calibration strategy, therefore, is of utmost importance when beginning any analysis. In the field of analytical chemistry, there are three most commonly used calibration methods: …

    wfu Repository record for NON-TRADITIONAL CALIBRATION STRATEGIES FOR APPLICATIONS IN ATOMIC SPECTROMETRY (opens in a new tab)

  10. A study of integrating large-scale variety trial data and phenology-based hybrid modeling for cultivar-level soybean yield prediction

    … This thesis advances methods to improve the calibration and predictive capacity of the DSSAT-CROPGRO-Soybean model and its integration with data-driven approaches. The first study introduces a yield-only calibration strategy that uses likelihood-based optimization and a large variety-trial …

    missouri Repository record for A study of integrating large-scale variety trial data and phenology-based hybrid modeling for cultivar-level soybean yield prediction (opens in a new tab)

  11. Calibration of the E and B EXperiment (EBEX), a balloon-borne cosmic microwave background polarimeter.

    We discuss pre-flight calibration of the E and B EXperiment (EBEX), a balloon-borne telescope designed to measure the B-mode polarization anisotropy of the cosmic microwave background (CMB). EBEX will observe the sky with 8' resolution in each of three bands centered on 150, 250 and 410 GHz. …

    umn Repository record for Calibration of the E and B EXperiment (EBEX), a balloon-borne cosmic microwave background polarimeter. (opens in a new tab)

  12. Global and Criteria Based Judgments of an Undergraduate Exit Writing Examination

    The effect of a calibration strategy requiring students to predict and postdict their scores on a writing exam was investigated. The utility of rubric-referenced calibration and the interaction between achievement and self-efficacy on calibration accuracy were also explored. Five hundred ninety six …

    odu Repository record for Global and Criteria Based Judgments of an Undergraduate Exit Writing Examination (opens in a new tab)

  13. Toward the Use of Modern Hydrologic Modeling Tools in Paleoclimate Studies

    … basin-lake systems in the Great Basin. A model calibration strategy is tested on a present-day application to explore modern proxy data that can be useful in calibrating and driving hydrologic models in ungauged watersheds. In two paleo applications, the model is used with proxy data such as …

    unr Repository record for Toward the Use of Modern Hydrologic Modeling Tools in Paleoclimate Studies (opens in a new tab)

  14. Can Practice Calibrating by Test Topic Improve Public School Students' Calibration Accuracy and Performance on Tests?

    The effect of a calibration strategy requiring students to predict their scores for each topic on a high stakes test was investigated. The utility of self-efficacy towards predicting achievement and calibration accuracy was also explored. One hundred and ten sixth grade math students enrolled in an …

    odu Repository record for Can Practice Calibrating by Test Topic Improve Public School Students' Calibration Accuracy and Performance on Tests? (opens in a new tab)

  15. Microscopic Simulation and Evaluation of the Roundabout Capacity Model in Highway Capacity Manual

    … coefficients. Each followed a different calibration strategy and compared with the Richfield model. It was found that calibration can significantly enhance the accuracy of the default HCM model and calibrating only the intercept of the default HCM model can produce a model with similar …

    umn Repository record for Microscopic Simulation and Evaluation of the Roundabout Capacity Model in Highway Capacity Manual (opens in a new tab)

  16. Methods for harmonizing and calibrating quantitative mass spectrometry experiments

    … In Chapter 2, I describe a single-point external calibration strategy to calibrate signal intensity measurements to a common reference material, which places MS measurements on the same scale and harmonizes signal intensities between instruments, acquisition methods, and sites. In Chapter 3, I …

    washington Repository record for Methods for harmonizing and calibrating quantitative mass spectrometry experiments (opens in a new tab)

  17. The Near-Infrared Imaging Channel for the Euclid Dark Energy Mission : Development of Critical Opto-Mechanical Components and an Instrument Calibration Concept

    … in this thesis. I have also developed a calibration strategy to meet the channel’s stringent high level calibration requirement. This includes specific work on optimizing the survey strategy for the retrospective calibration of the survey-wide dataset and also hardware development …

    heid-diss Repository record for The Near-Infrared Imaging Channel for the Euclid Dark Energy Mission : Development of Critical Opto-Mechanical Components and an Instrument Calibration Concept (opens in a new tab)

  18. Simulating the risk of liver fluke infection in the UK through mechanistic hydro-epidemiological modelling

    … patterns, but also introduce an expert-driven calibration strategy to make it more robust to data with limited reliability and in the presence of climate change. Secondly, we use HELF with sensitivity analysis to investigate disease risk drivers across the UK, and<br/>explore opportunities for …

    bristol Repository record for Simulating the risk of liver fluke infection in the UK through mechanistic hydro-epidemiological modelling (opens in a new tab)

Page 1 of 4