Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 12 of 12 for “"Calorimeter design"”
-
A Novel Metrology Standard for Synchrotron Produced Monochromatic X-ray Beams
… evaluated using a purpose built novel aluminum calorimeter design. Finite element modeling and radiation transport simulations were performed to refine the design, calculate correction factors, and assess influence quantities. Two iterations of the design were constructed to test calorimeter …
-
Search for the double beta decay of Zr-96 with NEMO-3 and calorimeter development for the SuperNEMO experiment
… of 7% FWHM at 1 MeV has been obtained for the calorimeter baseline design of SuperNEMO which is currently in the R&D phase. This result not only meets the requirement stipulated by the R&D proposal, but is unprecedented for this type of calorimeter design.
-
Uncertainty analysis of steady-state calorimetric emissivity measurements
… for which the uncertainty in other ASTM C835-06 designs, or similar calorimetric emissometers, can be evaluated. This is achieved by using an uncertainty analysis described by the JCGM 100:2008: Evaluation of measurement data -- Guide to the expression to the uncertainty in measurement, or GUM. A …
-
The sensitivity of the NEMO technique to neutrinoless double beta decay and the commissioning of the SuperNEMO demonstrator module
… beta-like events using its separated tracker-calorimeter design. Commissioning tasks for the calorimeter and tracker are presented. The quality of the SuperNEMO PMT pulse shapes is investigated and a novel approach to measuring the PMT time resolution is developed. The model development, …
-
A water calorimeter for high energy X-rays and electrons
… energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The …
-
Search for the neutrinoless double beta decay of 100Mo with the NEMO3 detector and calorimeter research and development for the SuperNEMO experiment
… ��\beta\beta decay experiment, based on the design and experience of NEMO3. Due to start demonstrator operation in 2013, SuperNEMO aims to achieve a sensitivity of 10^26 years, corresponding to \langle M\nu e\rangle < 50-100meV using ^82Se. An alternative to the baseline calorimeter design …
-
Calorimetry at a Future Linear Collider
This thesis describes the optimisation of the calorimeter design for collider experiments at the future Compact LInear Collider (CLIC) and the International Linear Collider (ILC). The detector design of these experiments is built around high-granularity Particle Flow Calorimetry that, in contrast …
-
Application of Deep Learning Techniques for Identification of Double Beta Decay Events in the SuperNEMO Experiment
… ⟨mββ⟩ < 0.2 − 0.55 eV) [1]. Its unique tracker-calorimeter design allows full topology and kinematics reconstruction, providing the opportunity to study both single- and double-electron energy distributions. A scaled up version of SuperNEMO will be able to probe the Majorana neutrino masses down …
-
Construction and testing of a respiratory apparatus for equine
Experiments were initiated to design and construct a respiratory apparatus for equine based on the indirect, open circuit method of calorimetry. The face mask, of light plexiglass, fit over the muzzle of the animal and was secured to the head, via a modified halter. Six one-way rubber inhalation …
-
Isothermal Micro(bio-)calorimetry - Method Optimization and Instrument Development for a Rapid and Reliable Detection of Bacteria
… micro(bio-)calorimetric test system was designed to meet the requirements for detecting bacterial contaminations. In particular, the sample vessel geometry and the operating temperature perfectly matched the microbiological analysis. Within this development work, numerical models were …
-
Studies on the metabolic response to thermal injury in the rat
… layer calorimetry system to hold one rat was designed and constructed by the author in collaboration with the Department of Clinical Physics and Bioengineering of the Western Regional Hospital Board. The calorimeter is capable of operating over a range of ambient temperature and humidity …
-
Metal and Gas Adsorption on High-surface-area Catalyst Support Materials: Energetics by Calorimetry and Adsorbate Structure
… isotherm (EAI). The metal vapor adsorption calorimeter described in Section 2.1 has been applied to drop-cast films of metal–organic frameworks (MOFs) NU-1000 described in Chapter 3. The Brunauer–Emmett–Teller (BET) system described in Section 2.2 has been used to measure equilibrium …