Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 3849 for “"Calorimetry."”.
-
Multiple representations in calorimetry
… concepts of temperature and energy transfer in calorimetry. The focus is placed on which type of representation promotes students' understanding of these concepts, and which representation(s) facilitates translations to other types. This study considers verbal, mathematical, and graphical …
-
Heat Sensing in Muscle Calorimetry
… that made its use impractical for muscle calorimetry. A muscle calorimeter was subsequently developed that uses commercially available solid-state thermopiles. The calorimeter was capable of unprecedented power resolutions of 2.6 nW·Hz−1/2 at room temperature and 7.1 nW·Hz−1/2 at 37 °C. …
-
Forward calorimetry at hadron collider
Calorimeter has been an essential element of High Energy Physics Experiment for decades. As beam energies of hadron colliders reached the multi-TeV range, hermeticity of the calorimetric system became a high priority issue. Additional requirements arose from increased luminosity. The Forward …
-
Matrix Effects in Differential Scanning Calorimetry
Problems arise in differential scanning calorimetry (DSC) when large samples and high levels of amplification are used to enhance sensitivity. Artifact peaks are generated by the instrument, calorimetric sensitivity is reduced and DSC peaks are distorted as the transition interface passes through …
-
Calorimetry of room temperature deformed copper
"An adiabatic anisothermal differential calorimeter for the study of room temperature deformed 99.999% pure copper has been constructed. An annealed and a deformed specimen were heated at a constant rate in adiabatic surroundings and the differences in energy released between samples was obtained. …
-
Pressure perturbation calorimetry of protein unfolding
… calorimetric method called Pressure Perturbation Calorimetry (PPC). In this research, the aqueous methanol solutions have been used as a solvent system with a modified hydrogen bonded structure in relation to water. Protein thermal unfolding has been studied in these solutions, where the solvation …
-
Application of Pulse Calorimetry to Metal Systems
<p>The pulse calorimeter developed as a part of the author's masters thesis was used extensively in the doctoral research to determine the electrical resistivity and specific heat of Ni, Ni<sub>4</sub>Mo, Fe-A1 alloys and Ni-A1. The temperature range of measurements varied with different specimens …
-
MAPS calorimetry for a future linear collider
The International Linear Collider (ILC) is intended to be a new high precision electron-positron collider operating at the TeV scale. The studies detailed within this thesis deal primarily with the development of Monolithic Active Pixel Sensors (MAPS) which could be used as the sensitive component …
-
"Boil-off calorimetry" for determining food enthalpy
Thesis (M.S.)--Michigan State University. Dept. of Food Science and Human Nutrition, 1972
-
Differential scanning calorimetry studies of various fluorinated plastics
Partial fluorination of various hydrocarbon plastics have been done at different temperatures for different lengths of time. By visual inspection of the surface, polypropylene received the most effective surface fluorination while polyethylene received somewhat less effective fluorination. …
-
On-line calorimetry for analysis of producer gas
The purpose of this study is to design and construct an on-line calorimeter for analysis of producer gas with a quick response time. This project explores the use of platinum wire as a catalyst and to measure the temperature difference of a platinum catalyst bead. For a typical gasification test, …
-
The use of calorimetry to evaluate cotton seedling vigor
Not Available
-
QUANTIFICATION OF RADIATION INDUCED DAMAGE VIA DIFFERENTIAL SCANNING CALORIMETRY
The greatest limitation in nuclear energy has been the inability to characterize radiation damage in a measurable fashion. Ion beam irradiation has been used in place of neutrons to typically speed up the irradiation process however, this usually induces defects which are different from those …
-
Precision Low Temperature Calorimetry and Susceptibility of Magnetic Pyrochlores
Spin-ice models feature the same statistical disorder as water ice, which is identified as the source of zero-point entropy. Gapped topological excitations with properties of monopoles are associated with the violation of the magnetic flux divergence condition ∇⋅B=0, and electric charges are …
-
Characterizing GSK3β Interaction and Kinetics via Isothermal Titration Calorimetry
… metal-enzyme interaction.Isothermal titration calorimetry (ITC) is a label-free technique that measures the heat absorbed or released during binding interactions. Be2+ is hypothesized to inhibit GSK3β by competing with magnesium ions (Mg2+) for binding sites rich in acidic residues like …
-
Quantification of Flame Heat Feedback in Cone Calorimetry Tests
… rate (MLR) data. In addition to standard cone calorimetry, side and center flame heat flux was measured under the cone calorimeter using two water-cooled heat flux gauges. The heat flux results show relatively good agreement with prior studies. Heat transfer coefficients were developed from the …
-
Room Calorimetry as a Method of Measuring Metabolic Flexibility
… a hyperinsulinemic-euglycemic clamp and hood calorimetry. A study was performed to evaluate if room calorimetry alone could provide the same results and to examine how diet composition and exercise affect metabolic flexibility. Sixteen healthy males and females stayed overnight in a room …
Page 1 of 193