Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"Camera Motion-capture System"”

  1. A Low-Cost RGB-Based Multi-Camera Motion Capture System for Metric 3D Tracking of Mobile Robots

    Motion capture is a fundamental tool in experimental robotics, biomechanics, and human–machine interaction, where accurate three-dimensional position estimation is required for system validation, performance analysis, and reproducibility. Commercial optical motion capture systems achieve high …

    buffalo Repository record for A Low-Cost RGB-Based Multi-Camera Motion Capture System for Metric 3D Tracking of Mobile Robots (opens in a new tab)

  2. The biomechanical analysis of the hand in rheumatoid arthritis patients with MCP arthroplasty

    … fracture of the elastomer occurs so frequently. Motion analysis was used to determine range of motion (ROM) of the metacarpophalangeal (MCP) joints in patients with rheumatoid arthritis, both without and with arthroplasty, to determine how the procedure affects motion of the joint. A 12 camera …

    birmingham Repository record for The biomechanical analysis of the hand in rheumatoid arthritis patients with MCP arthroplasty (opens in a new tab)

  3. Corticocortical Connections between the Primary Motor and Somatosensory Cortices in the Macaque

    … were somatotopically dissimilar. We used a multi-camera motion capture system to track the kinematics of reflective markers placed on the hand and arm of the monkey, from which we reconstructed joint kinematics. High-density multi-electrode arrays were implanted in non-human primates to record …

    chicago-thes Repository record for Corticocortical Connections between the Primary Motor and Somatosensory Cortices in the Macaque (opens in a new tab)

  4. Assessment of Coordination and Proprioception in Youth With Autism Spectrum Disorder

    … 1.3 m/s for at least five trials each. An eight-camera motion capture system was used to collect three-dimensional (3D) kinematics for each subject. After in-lab data collection, subjects were given an accelerometer to wear to measure physical activity levels over a span of at least four days. To …

    odu Repository record for Assessment of Coordination and Proprioception in Youth With Autism Spectrum Disorder (opens in a new tab)

  5. Corticocortical Connections between the Primary Motor and Somatosensory Cortices in the Macaque

    … were somatotopically dissimilar. We used a multi-camera motion capture system to track the kinematics of reflective markers placed on the hand and arm of the monkey, from which we reconstructed joint kinematics. High-density multi-electrode arrays were implanted in non-human primates to record …

    chicago Repository record for Corticocortical Connections between the Primary Motor and Somatosensory Cortices in the Macaque (opens in a new tab)

  6. Effects of External Ankle Taping on Lower Extremity Kinetics and Kinematics in Young Adult Males

    … stabilizing devices serve to limit the range of motion of the involved joint. As the most common injury in collegiate athletes, ankle injuries are frequently supported by external devices such as external ankle tape. Changes in biomechanical values at the ankle may result in changes up the …

    ohiolink Repository record for Effects of External Ankle Taping on Lower Extremity Kinetics and Kinematics in Young Adult Males (opens in a new tab)

  7. A Biomechanical Simulation of Musculoskeletal Kinematics During Ambulation

    … muscle-length variation during ambulation. An 18 camera motion capture system was used to analyze 20 healthy individuals between the ages of 18 and 35. Following data collection, the data was processed through OpenSim and Visual3D. The kinematic output processed through the OpenSim model was then …

    marquette Repository record for A Biomechanical Simulation of Musculoskeletal Kinematics During Ambulation (opens in a new tab)

  8. Effect of heel height and wedge angle of high-heeled shoe on body posture

    … used to simulate different footbed shapes. A 6-camera motion capture system was applied to capture the body landmark positions. A 2-way repeated measurement is applied to study the wedge angle and effects of repeated measurements on the absolute displacement of each body landmark. To support the …

    hkust Repository record for Effect of heel height and wedge angle of high-heeled shoe on body posture (opens in a new tab)

  9. Biomechanical and Talar Cartilage Responses to Running in Individuals With Chronic Ankle Instability

    … for 30 minutes. Ankle joint kinematics were captured using a 12-camera motion capture system at 250 Hz, and vGRF were recorded at 1,000 Hz. Talar cartilage thickness and T2 relaxation times were assessed using MRI at three time points: pretest, immediately post-running (post1), and 20 minutes …

    byu Repository record for Biomechanical and Talar Cartilage Responses to Running in Individuals With Chronic Ankle Instability (opens in a new tab)

  10. The effects of the pitcher-ground interaction on fastball pitching velocity

    … pitching mechanics. This study utilized a 10-camera motion capture system and a custom pitching mound with three imbedded force plates. Pitchers were asked to throw 10 successful fastballs at top velocity to a target. Variables measured were maximum NLWV, GRF for the drive, stride, and …

    twu Repository record for The effects of the pitcher-ground interaction on fastball pitching velocity (opens in a new tab)

  11. Effects of Foot Type on Multi-Segment Foot Motion in High- and Low-Arched Female Recreational Athletes

    … developed and allow for direct examination of motion within the foot. Therefore, the purpose of the current studies is to directly examine motion within the foot during vertical loading and dynamic loading tasks. <strong>Methods:</strong> Ten high- and 10 low-arched female athletes performed …

    utk-theses Repository record for Effects of Foot Type on Multi-Segment Foot Motion in High- and Low-Arched Female Recreational Athletes (opens in a new tab)

  12. Does Psychological Readiness Affect Jump Biomechanics Across the Continuum of Care Following Anterior Cruciate Ligament Reconstruction?

    … groups using 76.7 as a cut–off score. A 10–camera motion capture system synchronized with two force plates was used to collect kinetic data while participants performed a double–leg drop jump and a single–leg vertical jump at the time of return to sport and 6 weeks later. The limb symmetry …

    twu Repository record for Does Psychological Readiness Affect Jump Biomechanics Across the Continuum of Care Following Anterior Cruciate Ligament Reconstruction? (opens in a new tab) Embargoed until 2026-12-01

  13. Enhanced Sensorimotor Kinematics of the Baseball Swing in Elite Batters During a Known Pitch Type

    … pitching in an indoor batting facility, a 12-camera motion capture system, and eye tracking glasses, each subject completed 20 totals trials across a known fastball, known curveball, and unknown mixed conditions. For the fastball trials only, pelvis rotation and angular velocities along with …

    ecu Repository record for Enhanced Sensorimotor Kinematics of the Baseball Swing in Elite Batters During a Known Pitch Type (opens in a new tab)

  14. Effects of Knee Sleeves on Knee Mechanics During Squats at Variable Depths

    … (D) and one with parallel squats (P). A ten-camera motion capture system was used to collect three-dimensional (3D) kinematics and electromyography (EMG) was used to record muscle activity of the vastus medialis, rectus femoris, gluteus maximus, gluteus medius, and biceps femoris. Between …

    odu Repository record for Effects of Knee Sleeves on Knee Mechanics During Squats at Variable Depths (opens in a new tab)

  15. Shock attenuation at the knee during walking in people with knee osteoarthritis: association with disease severity and effects of exercise

    … shock attenuation data were collected using a 13-camera motion capture system and muscle co-contraction was measured using electromyography (EMG) sensors. A multivariate regression model accounting for age, sex, and BMI was sued to analyze the association between shock attenuation at the knee and …

    bu Repository record for Shock attenuation at the knee during walking in people with knee osteoarthritis: association with disease severity and effects of exercise (opens in a new tab)

  16. Rigidez passiva do quadril e resistência mecânica passiva do mediopé estão associadas aos movimentos do membro inferior no plano frontal e transverso durante a marcha

    … view photographs were taken using a digital camera to calculate the angle formed between the forefoot and the bisection of the shank. The midfoot passive mechanical resistance was measured using the Torsimeter instrument, which is able to measure the torque passive resistance to forefoot …

    brazil-ufmg Repository record for Rigidez passiva do quadril e resistência mecânica passiva do mediopé estão associadas aos movimentos do membro inferior no plano frontal e transverso durante a marcha (opens in a new tab)

  17. Understanding the modulation of walking speed and exploring how this differs in people with Parkinson’s disease.

    … screen (MotekMedical, the Netherlands) and A 12-camera motion capture system (Vicon Motion Systems, UK) integrated with two embedded force plates and a wireless EMG system (Trigno, Delsys, USA) collected the biomechanical and muscle excitation data. Three gait cycles; before, during and …

    strathclyde Repository record for Understanding the modulation of walking speed and exploring how this differs in people with Parkinson’s disease. (opens in a new tab)

  18. EFFECT OF QUADRICEP STRENGTH SYMMETRY ON KNEE JOINT SYMMETRY DURING SLS IN ACLR AND HEALTHY INDIVIDUALS

    … isometrically at 60 degrees. Lastly, using a 10-camera motion capture system, participants completed 5 SLS per limb as well as a landing task from 75% their maximal hop distance. RESULTS: ACLR participants were split into two groups: those with>90% quadricep strength symmetry and those with <90% …

    ecu Repository record for EFFECT OF QUADRICEP STRENGTH SYMMETRY ON KNEE JOINT SYMMETRY DURING SLS IN ACLR AND HEALTHY INDIVIDUALS (opens in a new tab)

  19. Biomechanical changes to the trunk and lower extremities due to variations of the forward lunge exercise

    … done on two portable force platforms while an 8 camera motion capture system recorded the movement. A multivariate ANOVA was used to test for significant differences and interactions between variables.</p> <p>Results: Peak internal hip adduction moment, peak external knee varus moment and peak …

    iastate Repository record for Biomechanical changes to the trunk and lower extremities due to variations of the forward lunge exercise (opens in a new tab)

  20. Development of Novel Wearable Sensor Technology for Walking Training Toward Functional Restoration of Stroke Patients

    … As such, there is a lack of a practical motion capture system for walking training post-stroke. To address this issue, this thesis aimed to develop a novel wearable technology using inertial measurement units (IMUs) to measure walking patterns during therapeutic training sessions. Then, …

    alberta Repository record for Development of Novel Wearable Sensor Technology for Walking Training Toward Functional Restoration of Stroke Patients (opens in a new tab)

Page 1 of 2