Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 99 for “"Canadian Light Source"”.
-
Transition Radiation Monitors at the Canadian Light Source
… at select points along the beam line of the Canadian Light Source (CLS) synchrotron. The decision has been made to equip the specified facility locations with Transition Radiation Monitors (TRM) for diagnostic purposes. TRM systems use Optical Transition Radiation (OTR), the physical …
-
A Soft X-Ray Emission Endstation for the Canadian Light Source
Based on a previously completed design for a soft X-ray (50-1100 eV) emission spectrometer, an endstation was constructed for the Resonant Elastic and Inelastic X-ray Scattering (REIXS) beamline at the CLS. The optical design employed techniques and software tools developed in-house using …
-
Front end x-ray beam position monitors at the Canadian Light Source
… X-ray Beam Position Monitors (XBPM) used on the Canadian Light Source front ends is described in this thesis, from the design concepts to the practical implementation and commissioning. Surveyed into position to provide a fiducialized point of origin for incoming synchrotron radiation, the …
-
Laue monochromator performance calculations for a future Canadian light source diffraction beamline
The computational investigation of perfect and bent crystals both cylindrically and sagittaly, have led to the development of sets of optimized parameters to be used for the high energy wiggler beamline monochromator being built at the CLS. Using both Si and Ge in Bragg and Laue geometries, the …
-
Saskatoon's agricultural biotechnology cluster and the Canadian Light Source: an assessment of the potential for cluster extension
Clusters are a key focus of policy makers worldwide. A successful cluster is often characterised as a 'jig-saw' puzzle (Martin and Sunley, 2002) containing a range of actors (e.g., private firms, research institutes, civic associations, government entities and venture capital firms) and functions …
-
Designing and Commissioning of a Prototype High Energy Resolution Fluorescence Detection System at the Canadian Light Source
… at the Hard X-ray MicroAnalysis beamline at the Canadian Light Source. This study was carried out through the construction of an x-ray photon energy analyzer system based around a single Johann crystal on a Rowland circle with a half meter diameter. Using this system high resolution scans of …
-
Spectroscopic study of channel spectra phenomena in the synchrotron-based FTIR spectrometer at the Canadian Light Source
Recently, the high radiance of synchrotron sources was used to enhance FTIR spectrometer performance. However, excessive channel spectra when synchrotron sources are used degrade the quality of retrieved spectral parameters. In the research reported in this thesis, seven different techniques for …
-
A fiducial subject pre-alignment system for the Biomedical Imaging and Therapy beamlines at the Canadian Light Source
… Imaging and Therapy (BMIT) beamlines at the Canadian Light Source, we propose an effective and versatile means of positioning a wide range of subjects (human and animal) with a wide range of sizes using a laser-based fiducial system to define the region of interest (ROI) before imaging; i.e., …
-
Design of a high performance soft x-ray emission spectrometer for the REIXS beamline at the Canadian Light Source
The optical design of a soft X-ray (90-1100~eV) emission spectrometer for the Resonant Elastic and Inelastic X-ray Scattering (REIXS) beamline to be implemented at the CLS is presented. An overview of soft X-ray optical theory as it relates to diffraction gratings is given. The initial constraints …
-
Study of Electron Beam Instabilities in the Storage Ring at the Canadian Light Source Using the Transverse Feedback System
The Canadian Light Source (CLS) 2.9 GeV electron storage ring circulates hundreds of approximately 1 nC bunches of charge in an electromagnetic trap. The oscillatory motion of these electron bunches is coupled through the electromagnetic interaction with the vacuum chamber in which they circulate. …
-
A comparative study of the existing methods for their suitability to beam stabilization in Storage Ring at Canadian Light Source
… corresponds to about 3 μm deviations at the Canadian Light Source (CLS). Further, the higher the correction bandwidth, the better in the stabilization process. The correction bandwidth at CLS was expected to increase to be 45 Hz or higher from the current operating rate at 18 Hz. In addition, …
-
Optical characterization of samarium-doped fluorophosphate glass for x-ray dosimetry for microbeam radiation therapy at the Canadian Light Source
… the delivered dose. Samples irradiated at the Canadian Light Source synchrotron showed X-ray induced conversion that could be optically characterized by changes in the photoluminescence emission spectra to obtain irradiation dose. The conversion efficiency depends almost linearly on the …
-
Beam Transmission Efficiency Measurement of the Injector System of the Canadian Light Source for the Top-up Mode of Operation
The beam transmission efficiency was measured in terms of charge through the CLS accelerator complex to determine the performance of the injector system for top-up operation. Propagation through the injection system incurs notable losses from bending magnets, beam choppers along the way and the …
-
FABRICATION AND THERMAL ANALYSIS OF POLYIMIDE-BASED X-RAY MASKS AT THE SYNCHROTRON LABORATORY FOR MICRO AND NANO DEVICES, CANADIAN LIGHT SOURCE
… for Micro and Nano Devices (SyLMAND) at the Canadian Light Source (CLS) is a DXRL laboratory with continuous tuning capabilities for spectrum and power of the synchrotron beam. X-ray mask fabrication is one of the most demanding sequences associated with the entire processing chain and has …
-
Using the quadrupole scan technique to measure the electron emittance in the booster-to-storage ring transfer line at the canadian light source
The Canadian Light Source is a third generation synchrotron light source with an electron energy of 2.9 GeV on the University of Saskatchewan campus in Saskatoon, Saskatchewan. It consists of three accelerators: a linear accelerator, the Booster Ring, and the Storage Ring. There are two transfer …
-
Commissioning of a multipass discharge cell for the study of transient molecules of astrophysical interest using the far-IR beamline at the Canadian Light Source
… gas cell for the Far-Infrared Beamline at the Canadian Light Source (CLS). This cell was designed to generate transient molecules of astrophysical interest and was successfully used to collect high resolution rovibrational spectra of these species in the mid- and far-infrared regions (300 to …
-
Pilot Study for Examination of Injection Site Trauma and Injection Material Pathway Imaging through a Human Analog System
… Biomedical Imaging and Therapy Beamline at the Canadian Light Source Synchrotron can be used to monitor the path of an injection in a live animal through imaging. The third section involves engineering designs for the Biomedical Imaging and Therapy Beamline. A literature review was completed …
-
Lead Astray: Monte Carlo to Determine a Correction Factor for Chlorine Signals in μXRF Maps of Percutaneous Lead Absorption
… x-ray fluorescence (μXRF) imaging of skin at the Canadian Light Source BioXAS Imaging beamline. Individual elemental maps are generated from the fluorescence spectra using the program PyMCA. Although lead is the primary interest in μXRF maps, the concentration of other naturally occurring …
-
Optimizing and Analyzing X-Ray Powder Diffraction of Orthosilicate Cathodes using a Combined Synchrotron X-Ray Diffraction and Absorption Spectroscopy Setup
… at the Hard X-ray MicroAnalysis beamline in the Canadian Light Source. Determination of the atomic structure of ex situ orthosilicate cathode materials via Rietveld refinement is a goal, and provides a data quality benchmark for the improved setup. Instrumentation assembled for the improvement of …
-
An Effective Polychromatic X-ray Beam for Quantitative Analysis of Fossil Compositions
… X-ray Fluorescence data collected at the Canadian Light Source in Saskatchewan, Canada. Several methods to facilitate both qualitative and quantitative analysis of this data are used and developed. In particular, a method for replacing a polychromatic X-ray spectrum with an effective set …
Page 1 of 5