Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 97 for “"Capacitance measurements"”.

  1. Quantitative capacitance measurements using a scanning probe microscope

    … which an atomic force microscope with scanning capacitance microscopy (SCM) capability can be employed in a nontraditional fashion to quantitatively measure the capacitance of metal-oxide-semiconductor (MOS) structures. The capability to deduce sample capacitances is based on resonant frequency …

    ottawa-retro Repository record for Quantitative capacitance measurements using a scanning probe microscope (opens in a new tab)

  2. ELECTROCHEMICAL CAPACITANCE MEASUREMENTS TO STUDY MOLECULAR SURFACE INTERACTIONS

    … bulk membranous events to obtain the required measurements. This study looks to achieve two major objectives through the use of a novel technique, namely, the double layer capacitive method: 1) to analyze the electrochemical behavior of proteins adsorbed on Gold and Platinum metal electrode …

    clemson Repository record for ELECTROCHEMICAL CAPACITANCE MEASUREMENTS TO STUDY MOLECULAR SURFACE INTERACTIONS (opens in a new tab)

  3. Electrical Capacitance Measurements to Assess European Corn Borer Infestation in Maize

    … using non-destructive, electromagnetic measurements. Laboratory experiments and numerical simulation studies predicted changes in capacitance of stalks due to hollow core ECB damage. A guarded probe device to measure electrical impedance from 500 Hz to 100 kHz was designed and …

    byu Repository record for Electrical Capacitance Measurements to Assess European Corn Borer Infestation in Maize (opens in a new tab) Download PDF for Electrical Capacitance Measurements to Assess European Corn Borer Infestation in Maize (opens in a new tab)

  4. An analysis of precision methods of capacitance measurements at high frequency

    The compilation of material for this paper was done at the General Radio Company, Cambridge, Massachusetts, during the winter term of the third year of the postgraduate Electronics course.

    nps Repository record for An analysis of precision methods of capacitance measurements at high frequency (opens in a new tab)

  5. Applications of droplet interface bilayers: specific capacitance measurements and membrane protein corralling

    … bilayer area changes are used to make precise measurements of the specific capacitance of DIBs and to control the two dimensional concentration of a membrane protein reconstituted in the bilayer.</p><p> Chapter 1 provides a general introduction to the role of the lipid membrane en- vironment in …

    oxford Repository record for Applications of droplet interface bilayers: specific capacitance measurements and membrane protein corralling (opens in a new tab)

  6. Carbon Nanotube Transistors: Capacitance Measurements, Localized Damage, And Use As Gold Scaffolding

    … on carbon nanotube transistors. We measured the capacitance of individual carbon nanotubes. The density of states of a carbon nanotube will in?uence the tube?s capacitance. We report good agreement with theory and that we successfully probe the tube?s density of states. We show it is possible to …

    cornell Repository record for Carbon Nanotube Transistors: Capacitance Measurements, Localized Damage, And Use As Gold Scaffolding (opens in a new tab)

  7. Investigation of radiation damage induced effects on capacitance measurements of silicon particle detectors

    … the measurement techniques used for that is the capacitance-voltage measurement (CV) where the capacitance of the sensor is measured<br>as a function of the applied reverse bias voltage. It is evaluated and part of the standard sensor test procedure for unirradiated and lightly irradiated sensors …

    freiburg-diss Repository record for Investigation of radiation damage induced effects on capacitance measurements of silicon particle detectors (opens in a new tab)

  8. Calculation of defect densities in nano-crystalline and amorphous silicon devices using differential capacitance measurements

    … is presented. Through differential capacitance measurements, trap states can be accurately measured and profiled within the bandgap as a function of energy. Measurements were carried out on samples made at the Microelectronic Research Center at Iowa State University. Hydrogen …

    iastate Repository record for Calculation of defect densities in nano-crystalline and amorphous silicon devices using differential capacitance measurements (opens in a new tab)

  9. Towards Highly Sensitive Capacitance Measurements of a Quantum Anomalous Hall Phase in Van Der Waal Heterostructures

    … of the QAHE, we implement a highly sensitive capacitance measurement technique. We present theoretical background on the quantum Hall e↵ects and capacitance measurements to begin. We then present fabrication and measurements of four devices, two incorporating single layer graphene and two with …

    unlv Repository record for Towards Highly Sensitive Capacitance Measurements of a Quantum Anomalous Hall Phase in Van Der Waal Heterostructures (opens in a new tab) Download PDF for Towards Highly Sensitive Capacitance Measurements of a Quantum Anomalous Hall Phase in Van Der Waal Heterostructures (opens in a new tab)

  10. Μελέτη προσρόφησης και σχηματισμού υμενίων, τασενεργών ουσιών ή/και μιγμάτων τους, στη διεπιφάνεια υδραργύρου/ηλεκτρολυτικoύ διαλύματος

    … on mercury drop. Condensed films with low capacitance values and in some cases hemicylindrical and hemispherical surface micelles are formed at the interface. Inhomogeneous structures are also observed. This inhomogeneity expresses the transformation of the interfacial geometry from …

    greece Repository record for Μελέτη προσρόφησης και σχηματισμού υμενίων, τασενεργών ουσιών ή/και μιγμάτων τους, στη διεπιφάνεια υδραργύρου/ηλεκτρολυτικoύ διαλύματος (opens in a new tab)

  11. Measuring Acid Generation Kinetics in Photoresist Films via Capacitance Techniques

    … photoresists was developed that utilizes capacitance measurements from interdigitated electrodes. In this technique, a chemically amplified photoresist is first coated onto the interdigitated electrode sensors. Then, capacitance measurements are recorded from the sensor as the photoresist …

    gatech Repository record for Measuring Acid Generation Kinetics in Photoresist Films via Capacitance Techniques (opens in a new tab)

  12. Monitoring Vehicle Seat Occupancy Status and Tracking Human Passenger Activities Inside Vehicle Passenger Cabins

    … this dissertation presents a system employing a capacitance-sensing mat and a machine learning unit to monitor vehicle seat occupancy status and track passenger activities non-intrusively. While the mat integrates with vehicle seats to continuously yield capacitance measurements indicative of …

    clemson Repository record for Monitoring Vehicle Seat Occupancy Status and Tracking Human Passenger Activities Inside Vehicle Passenger Cabins (opens in a new tab)

  13. Silicon-based pH sensor for biological and environmental applications

    … We were not able to obtain consistent capacitance measurements for a particular pH solution. For some solutions we had extremely large variances in capacitance, yielding “noisy” measurements. However, in retrospect, there are many improvements that could be made to our device and …

    uiuc Repository record for Silicon-based pH sensor for biological and environmental applications (opens in a new tab)

  14. Correlation of the distribution curve with the dispersion curve of cellulose nitrate

    … The parallel resistance method is used for capacitance measurements is a nickel cell. Comparison of the distribution curve and the dispersion curve above a distinct similarity between the two curves. A relationship of the log frequency to intrinsic viscosity has been derived and appears to …

    vt Repository record for Correlation of the distribution curve with the dispersion curve of cellulose nitrate (opens in a new tab)

  15. Characterization of the Motion and Mixing of Droplets in Electrowetting on Dielectric Devices

    … Model predictions were validated using optical measurements of the droplet interface in the vertical plane. It was found that the capillary force and interface shape predicted by the equilibrium model were over an order of magnitude more accurate than predictions from the model commonly used in …

    toronto-retro Repository record for Characterization of the Motion and Mixing of Droplets in Electrowetting on Dielectric Devices (opens in a new tab)

  16. Cell coupling and exocytosis measured in intact mouse pancreatic islets Control of {delta}-cell secretion

    Patch-clamp and capacitance measurements were applied to α-, β- and δ-cells in intact mouse pancreatic islets. The maximum rate of β-cell exocytosis during a depolarization to 0 mV was 14 granules/s, <5% of that observed in isolated β-cells. β-cell exocytosis exhibited bell-shaped voltage …

    lund Repository record for Cell coupling and exocytosis measured in intact mouse pancreatic islets Control of {delta}-cell secretion (opens in a new tab) Download PDF for Cell coupling and exocytosis measured in intact mouse pancreatic islets Control of {delta}-cell secretion (opens in a new tab)

  17. Development of a cell free system for analysis of the mechanisms of exocytosis using total internal reflectance microscopy

    … regulated exocytosis and these include capacitance measurements, amperometry and single-cell imaging. Reconstitution from defined components of the steps leading to exocytosis has not yet been achieved, whereas the investigation of the actual exocytotic event is well described. Access to …

    edinburgh Repository record for Development of a cell free system for analysis of the mechanisms of exocytosis using total internal reflectance microscopy (opens in a new tab)

  18. Nature of Large Vesicle Exocytosis in Pancreatic β-cells: Release of ATP and GABA

    … electrophysiological techniques such as measurements of cell membrane capacitance and amperometry are used to detect exocytotic events. A novel method was developed in this study based on the expression of P2X2 receptor channel in secreting cells. The presence of ATP sensitive channel on …

    lund Repository record for Nature of Large Vesicle Exocytosis in Pancreatic β-cells: Release of ATP and GABA (opens in a new tab) Download PDF for Nature of Large Vesicle Exocytosis in Pancreatic β-cells: Release of ATP and GABA (opens in a new tab)

Page 1 of 5