Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 90 for “"Capillary column"”.

  1. Extended macroscopic dispersion model with applications to confined packed beds and capillary column inverse gas chromatography

    … scale proportional to R2/<DT> where R is the column radius and <DT> is the area averaged lateral dispersion coefficient. The extended model encouraged study of the consequences of the additional dispersion terms in other applications such as the pulse spread in the field of capillary column …

    unsw Repository record for Extended macroscopic dispersion model with applications to confined packed beds and capillary column inverse gas chromatography (opens in a new tab)

  2. IMPLEMENTING 1.5 MILLIMETER INTERNAL DIAMETER COLUMNS AND A PORTABLE CAPILLARY COLUMN INSTRUMENT INTO MONOCLONAL ANTIBODY ANALYTICAL WORKFLOWS

    Using 1.5 mm inner diameter (i.d.) columns to bridge the gap between routinely used 2.1 mm i.d. columns and capillary bore columns allows for a sequential but significant increase in performance without the need for specialized equipment associated with very low dispersion liquid chromatography …

    rowan Repository record for IMPLEMENTING 1.5 MILLIMETER INTERNAL DIAMETER COLUMNS AND A PORTABLE CAPILLARY COLUMN INSTRUMENT INTO MONOCLONAL ANTIBODY ANALYTICAL WORKFLOWS (opens in a new tab)

  3. DEVELOPMENT OF A NEW CHIRAL MONOLITHIC CAPILLARY COLUMN AND A FLUORESCENCE SPECTROSCOPIC STUDY OF A SELECTIVE OFF-ON PET SENSOR FOR THE DETECTION OF ZINC IONS

    In the first study, a new µ-HPLC column was developed using a monolithic silica gel as a column substrate for chiral separation by covalently modifying with (S, S)-Whelk-O1 chiral selector. The monolithic stationary phase was generated through a sol-gel process and prepared in situ in a 100 µm i.d. …

    siu-theses Repository record for DEVELOPMENT OF A NEW CHIRAL MONOLITHIC CAPILLARY COLUMN AND A FLUORESCENCE SPECTROSCOPIC STUDY OF A SELECTIVE OFF-ON PET SENSOR FOR THE DETECTION OF ZINC IONS (opens in a new tab)

  4. The Analysis of Nitro Polycyclic Aromatic Hydrocarbons in Diesel Exhaust and Urban Airborne Particulate Samples

    … were taken through this procedure.</p> <p>Capillary column gas chromatography (GC) with flame ionization and nitrogen-selective detection was used for the detection and quantitation of nitro-PAHs. Confirmation of the identity of nitro-PAHs was done by capillary column GC-MS in the …

    mcmaster Repository record for The Analysis of Nitro Polycyclic Aromatic Hydrocarbons in Diesel Exhaust and Urban Airborne Particulate Samples (opens in a new tab)

  5. An improved method of gas chromatographic determination of trace organic vapors in ambient air collected in canisters

    … then thermally transfering it onto the head of a capillary column in a gas chromatograph. The column effluent is measured by a parallel flame ionization detector (FID), and electron capture detector (ECD). The problems associating with quantitative transfer of the sample to the initial …

    njit Repository record for An improved method of gas chromatographic determination of trace organic vapors in ambient air collected in canisters (opens in a new tab)

  6. Characterization and Applications of a Water Stationary Phase in Capillary Gas Chromatography

    … investigated as a stationary phase in packed column GC. This resulted in an inefficient stationary phase that largely evaporated during operation. This thesis details an investigation of how to form and maintain a water stationary phase in a capillary column GC setting without any significant …

    calgary Repository record for Characterization and Applications of a Water Stationary Phase in Capillary Gas Chromatography (opens in a new tab)

  7. Hand-portable Capillary Liquid Chromatography Instrumentation

    … focuses on the development of hand-portable capillary liquid chromatography (LC) instrumentation. In this work, battery-operable nano-flow pumping systems (isocratic and gradient) were developed and integrated with portable UV-absorption detectors for capillary LC. The systems were reduced in …

    byu Repository record for Hand-portable Capillary Liquid Chromatography Instrumentation (opens in a new tab) Download PDF for Hand-portable Capillary Liquid Chromatography Instrumentation (opens in a new tab)

  8. The Synthesis and Characterisation of Long-Chain Fatty Acids

    … separation, both capillary column GLC and reversephase HPLC, was readily achieved on the basis of chain length and configuration of the double bond. Furthermore, the partial separation of positional isomers was achieved.<br/><br/>NMR spectroscopy unambiguously …

    southwales Repository record for The Synthesis and Characterisation of Long-Chain Fatty Acids (opens in a new tab) Download PDF for The Synthesis and Characterisation of Long-Chain Fatty Acids (opens in a new tab)

  9. Investigations into the determination of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) by capillary gas chromatography

    … congeners, representing 10 isomeric groups) by capillary gas chromatography coupled with mass spectrometry (GC/MS, for PAHs) and electron capture detection (GC/ECD , for PCBs) were studied, with emphasis on the effect of solvent. Having various volatilities and different polarities, solvent …

    brock Repository record for Investigations into the determination of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) by capillary gas chromatography (opens in a new tab)

  10. Structure and Utilization of Cell Walls of Normal and Brown Midrib Mutant Sorghum X Sudangrass Hybrids

    … were separated and quantified on a phenylmentyl capillary column. Analysis of alkali-labile phenolics, which included vanillin and the cis and trans isomers of p-coumaric and ferulic acids, required less than 15 minutes. High resolution gas chromatography, utilizing a phenylmethyl-fused silica …

    uiuc Repository record for Structure and Utilization of Cell Walls of Normal and Brown Midrib Mutant Sorghum X Sudangrass Hybrids (opens in a new tab)

  11. Analytical methods and instrumentation for the determination of organophosphorus pesticides in fruit and vegetable substrates

    … pesticides has beeninvestigated, using capillary gas liquid chromatography-mass spectrometry (GC-MS), andpacked and wide bore capillary gas liquid chromatography with electron capture detection(GC-ECD).The first part of this thesis (Chapter 3) embodies the application of high …

    salford Download PDF for Analytical methods and instrumentation for the determination of organophosphorus pesticides in fruit and vegetable substrates (opens in a new tab)

  12. High resolution gas chromatography of conjugated estrogens with glass capillary columns

    … and β-estradiol/α-dihydroequilin, capillary column gas chromatography was investigated. A variety of derivatives of estrogens, suitable for gas chromatography, such as trimethylsilyl ethers, methoxime-trimethyl-silyl ethers, tert.butyl dimethyl silyl ethers, heptafluorobutyrates, …

    ubc Repository record for High resolution gas chromatography of conjugated estrogens with glass capillary columns (opens in a new tab) Download PDF for High resolution gas chromatography of conjugated estrogens with glass capillary columns (opens in a new tab)

  13. Geomorphological and glaciological studies, Eastern Breidamerkurjokull, Iceland

    … by thin layer chromatography (t.l.c.) and capillary column gas-liquid chromatography (g.l.c.). The results are discussed and appear to indicate that thermal and catalytic alteration of alkanes and other straight chain lipid materials could be a contributory process to the generation of …

    glasgow Repository record for Geomorphological and glaciological studies, Eastern Breidamerkurjokull, Iceland (opens in a new tab) Download PDF for Geomorphological and glaciological studies, Eastern Breidamerkurjokull, Iceland (opens in a new tab)

  14. Investigating Novel Methods for Using Water in Analytical Extractions and Separations

    … properties of a water stationary phase in a capillary supercritical fluid chromatography (SFC) system are investigated. It is shown that the water phase is uniformly deposited inside stainless steel (SS) columns of varying length and i.d., resulting in a consistent water coverage per area. …

    calgary Repository record for Investigating Novel Methods for Using Water in Analytical Extractions and Separations (opens in a new tab)

  15. Novel Switchable Stationary Phase Methods For Supercritical Fluid Chromatography

    … organic bases. The method uses a stainless steel capillary column coated with water containing NH4OH, which was also used to hydrate the system. In this way, the pH of the water stationary phase can be effectively altered to help control the ionization of organic base analytes and greatly improve …

    calgary Repository record for Novel Switchable Stationary Phase Methods For Supercritical Fluid Chromatography (opens in a new tab)

  16. Ανάπτυξη αναλυτικής τεχνικής φασματομετρίας μάζας για παρακολούθηση και έλεγχο διεργασιών: εφαρμογή σε πιλοτική κομποστοποίηση

    … system that consists of pulsed sampling system, capillary column as transfer line and mass spectrometer was used for online monitoring of complicated mixtures of gases and VOCs produced in a bioreactor during composting of green kitchen waste. The objectives of the PhD thesis which were achieved …

    greece Repository record for Ανάπτυξη αναλυτικής τεχνικής φασματομετρίας μάζας για παρακολούθηση και έλεγχο διεργασιών: εφαρμογή σε πιλοτική κομποστοποίηση (opens in a new tab)

  17. Anodic oxygen-transfer electrocatalysis at iron-doped lead dioxide electrodes

    <p>Capillary electrophoresis (CE) has emerged as one of the most versatile separation methods. However, efficient separation is not sufficient unless coupled to adequate detection. The narrow inner diameter (I.D.) of the capillary column raises a big challenge to detection methods. For UV-vis …

    iastate Repository record for Anodic oxygen-transfer electrocatalysis at iron-doped lead dioxide electrodes (opens in a new tab)

Page 1 of 5