Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 154 for “"Capillary tube"”.

  1. Flashing flow of refrigerant HFC-134a through a diabatic capillary tube

    Capillary tubes are components in refrigerating systems which act as expansion and flow-rate controlling devices. The proper design of capillary tubes is an important factor in performance efficiency of these systems. An experimental test loop was designed and built for testing the capillary tube. …

    concordia Download PDF for Flashing flow of refrigerant HFC-134a through a diabatic capillary tube (opens in a new tab)

  2. A Numerical Approach for Oil Slug Mobilization in a Capillary Tube Under Absence and Presence of External Excitations

    … an oil drop is placed in a small diameter tube filled with water and then flushed from the tube by injecting more water. The pressure difference between the inlet and outlet of the tube is then recorded. Unlike past research in this field, this work employs dimensionless numbers and …

    regina Repository record for A Numerical Approach for Oil Slug Mobilization in a Capillary Tube Under Absence and Presence of External Excitations (opens in a new tab) Download PDF for A Numerical Approach for Oil Slug Mobilization in a Capillary Tube Under Absence and Presence of External Excitations (opens in a new tab)

  3. An experimental evaluation of capillary tube-suction line heat exchanger performance with alternative refrigerants HFC-134a and HFC-152a

    … and HFC-152a are potential replacements;The capillary tube is the predominant expansion device found in household refrigerators. It is usually soldered to the suction line for three to five feet of length, thus, creating a simple counter-flow heat exchanger. Heat exchanger performance is …

    iastate Repository record for An experimental evaluation of capillary tube-suction line heat exchanger performance with alternative refrigerants HFC-134a and HFC-152a (opens in a new tab)

  4. CO2 sequestration in a capillary tube via an interfacial chemical reaction between pressurized CO2 gas and aqueous glycerol Ca(OH)2 solution.

    … and 0.437 Pa-s) by pressurized CO2 gas in a capillary tube were performed. The experiments were also performed for various volumes of aqueous glycerol Ca(OH)2 solution (15, 17.5, 20 and 22.5 µl) and different pressures of CO2 gas with a range of 0.2 psig < P < 1.0 psig with an increment of …

    iastate Repository record for CO2 sequestration in a capillary tube via an interfacial chemical reaction between pressurized CO2 gas and aqueous glycerol Ca(OH)2 solution. (opens in a new tab)

  5. A Prediction Model for Adiabatic and Diabatic Capillary Tubes with Alternative Refrigerants

    The capillary tube is a very common throttling device located between the condenser and evaporator in a refrigeration system. In some refrigerant systems, a section of the capillary tube is connected to a section of the vapor return line (suction line) that exits the evaporator, which creates the …

    tamu Repository record for A Prediction Model for Adiabatic and Diabatic Capillary Tubes with Alternative Refrigerants (opens in a new tab)

  6. Theoretical and experimental investigation of oscillating heat pipes

    … oscillation characteristics of slug flow in a capillary tube is presented. The model considers the vapor bubble as the gas spring for the oscillating motions in a capillary tube including effects of capillary force, gas spring constant, dimensions, gravitational force, and initial pressure …

    missouri Repository record for Theoretical and experimental investigation of oscillating heat pipes (opens in a new tab)

  7. Investigation of the condensing and expansion behaviors of alternative refrigerants

    … alternatives while condensing in an enhanced tube with 0% to 3% oil and while expanding in a capillary tube. The capillary tube study examined the mass flow rate of refrigerants while expanding, with an emphasis on the nature of the metastable region for both single component refrigerants and …

    uiuc Repository record for Investigation of the condensing and expansion behaviors of alternative refrigerants (opens in a new tab)

  8. A Study on the Flow Behavior of Microbubbles in Capillary Tubes

    … applications involve microbubble flow thorough capillary environments. This study offers a better understanding of microbubbles’ flow behavior in capillary tubes to provide a fundamental understanding of their flow in capillary environments. Stabilized microbubbles have been injected to a …

    calgary Repository record for A Study on the Flow Behavior of Microbubbles in Capillary Tubes (opens in a new tab)

  9. Selective Pericyte Recruitment to EC-lined Tubes, Vessel Assembly Enhancement Through Pericyte TIMP-3 Induction, and Pericyte TBX2 in Capillary Formation and Maturation

    … narrow and elongated endothelial cell (EC)-lined tubes with associated pericytes anchored to the abluminal tube surface. Our laboratory demonstrated that dynamic interactions between ECs and pericytes during capillary tube network assembly are required for basement membrane matrix deposition and …

    usf Repository record for Selective Pericyte Recruitment to EC-lined Tubes, Vessel Assembly Enhancement Through Pericyte TIMP-3 Induction, and Pericyte TBX2 in Capillary Formation and Maturation (opens in a new tab)

  10. Determining the efficacy of a biosensor to detect calpastatin, a meat tenderness indicator

    … one was an optical fiber and trial two was a capillary tube. Warner-Bratzler shear force was also performed on a steak from each carcass. In trial one, correlations were generated from each sampling period to determine the most closely correlated sampling times between the traditional assay …

    missouri Repository record for Determining the efficacy of a biosensor to detect calpastatin, a meat tenderness indicator (opens in a new tab)

  11. INVESTIGATION OF A FACTOR RELEASED BY NEOPLASTIC CELLS WHICH PRODUCES A CHEMOKINETIC RESPONSE IN ACTIVATED MACROPHAGES

    … released from the membrane of the tumor cells. A capillary tube assay was developed to expediently monitor the chemokinetic activity of macrophages incubated in whole and fractionated media. The capillary tube assay was found to be capable of detecting both chemokinetic and chemotactic …

    vcu Repository record for INVESTIGATION OF A FACTOR RELEASED BY NEOPLASTIC CELLS WHICH PRODUCES A CHEMOKINETIC RESPONSE IN ACTIVATED MACROPHAGES (opens in a new tab)

  12. COMPUTATIONAL INVESTIGATION OF TURBULENT BLOOD FLOW AND HEMOLYSIS IN BIOMEDICAL DEVICES

    … of experiments in a Couette flow viscometer, a capillary tube, and a jet were used to examine extensive properties of the turbulent flow field and to investigate contributing factors for red blood cell hemoglobin release in turbulence by eddy analysis. Moreover, flows in a Couette viscometer and …

    oklahoma-thes Repository record for COMPUTATIONAL INVESTIGATION OF TURBULENT BLOOD FLOW AND HEMOLYSIS IN BIOMEDICAL DEVICES (opens in a new tab)

  13. Nonlinear thermomechanical finite-element modeling, analysis and characterization of multi-turn oscillating heat pipes

    … mode (bottom or top heating), diameter of the capillary tube, number of turns, physical properties of the working fluid, and others. This thesis develops a fully nonlinear thermomechanical finite-element model of oscillating heat pipes that can accurately predict the oscillation frequency and …

    missouri Repository record for Nonlinear thermomechanical finite-element modeling, analysis and characterization of multi-turn oscillating heat pipes (opens in a new tab)

  14. Simulation of a micro heat pump cycle

    … used in the micro heat pump, i.e. fluted tube water heating condenser, air-cooled evaporator, reciprocating compressor and capillary tube. The theory on which each model is based, was derived from first principles and the relevant model algorithms were developed and implemented in C++ …

    nwu-za Repository record for Simulation of a micro heat pump cycle (opens in a new tab)

  15. Identification of KIAA1024 as a novel cell surface protein involved in angiogenesis

    … altered actin stress fiber formation and reduced capillary tube formation. Interestingly, unlike its inhibitory effect on capillary tube formation, overexpression of KIAA1024 in PAE cells increased cell migration, cell survival and inhibited phosphorylation of pro-apoptosis p38MAPK. Taken …

    bu Repository record for Identification of KIAA1024 as a novel cell surface protein involved in angiogenesis (opens in a new tab)

  16. Dissolution dynamics of liquid/liquid binary mixtures in porous media

    … can be roughly represented as a network of capillary tubes. This allowed for the initial research to be focused on understanding the dissolution dynamics of binary mixtures (i.e. glycerol/water, soybean oil/hexane, and isobutyric acid/water) within single capillary tubes. Further, the …

    soton Download PDF for Dissolution dynamics of liquid/liquid binary mixtures in porous media (opens in a new tab)

  17. Measuring chemotaxis in Borrelia burgdorferi the Lyme disease spirochete

    … it much faster. To assay chemotaxis with the capillary tube assay, one must enumerate cells. This was previously difficult because cell enumeration was slow, laborious, and ineffectual at low concentrations. We overcame these limitations by initially developing a protocol for enumerating cells …

    wvu Repository record for Measuring chemotaxis in Borrelia burgdorferi the Lyme disease spirochete (opens in a new tab)

  18. Flow of oil-refrigerant 12 solutions through horizontal capillary tubes and application as an oil return device for refrigerant compressores

    … solutions through horizontal capillary tubes was studied. The effect of different concentrations of solution on the mass flow through tubes of different bores and lengths was the primary concern. This is a now field of investigation; no previous work had been published on …

    glasgow Download PDF for Flow of oil-refrigerant 12 solutions through horizontal capillary tubes and application as an oil return device for refrigerant compressores (opens in a new tab)

  19. Sapphire fiber in optical sensors

    … One solution demonstrated here is the sapphire capillary tube splice, in which the two fibers are aligned in a sapphire capillary tube and bound together with alumino-silicate glass. Sapphire fiber optical sensors cannot use standard interferometric techniques used with silica fibers because …

    vt Repository record for Sapphire fiber in optical sensors (opens in a new tab)

Page 1 of 8