Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"Capillary-Channeled Polymer"”.

  1. CAPILLARY-CHANNELED POLYMER FIBERS AS STATIONARY PHASES FOR PROTEIN CHROMATOGRAPHY

    Capillary-channeled polymer (C-CP) fibers have been studied in this laboratory as stationary phases for protein separations in high-performance liquid chromatography (HPLC). C-CP fibers are uniquely shaped so as to include eight continuous capillary-channels which interdigitate once packed into a …

    clemson Repository record for CAPILLARY-CHANNELED POLYMER FIBERS AS STATIONARY PHASES FOR PROTEIN CHROMATOGRAPHY (opens in a new tab)

  2. Multidimensional Chromatographic Coupling Strategies Implementing Capillary-Channeled Polymer Fiber Stationary Phases

    … field requiring highly pure products includes polymers, where they are used for everyday plastics to bioprosthetics. The physiochemical properties of polymers are tied to their function; therefore, their characterization is of utmost importance. Approaches detailing the molecular weight and …

    clemson Repository record for Multidimensional Chromatographic Coupling Strategies Implementing Capillary-Channeled Polymer Fiber Stationary Phases (opens in a new tab)

  3. Isolation of Proteins and Extracellular Vesicles via Capillary-Channeled Polymer Fiber Stationary Phases

    Capillary-channeled polymer (C-CP) fiber stationary phases have been developed by the Marcus lab as an alternative approach to traditional, commercially-available silica-based supports for biomacromolecule separations. C-CP columns are created with natural and synthetic base polymers in a variety …

    clemson Repository record for Isolation of Proteins and Extracellular Vesicles via Capillary-Channeled Polymer Fiber Stationary Phases (opens in a new tab)

  4. Surface Modifications of Capillary-Channeled Polymer (C-CP) Fiber Stationary Phases for Protein Separations

    … HPLC stationary phase for protein separation. Capillary-channeled Polymer (C-CP) fibers have been studied as HPLC stationary phase for protein separation in the Marcus research group for years. C-CP fibers are made from melting extrusion of commonly used polymers such as polypropylene (PP), …

    clemson Repository record for Surface Modifications of Capillary-Channeled Polymer (C-CP) Fiber Stationary Phases for Protein Separations (opens in a new tab)

  5. Development of Capillary-Channeled Polymer (C-CP) Fiber as Stationary Phase for Biological Sample Application

    Capillary-channeled polymer (C-CP) fibers as an alternative support/stationary phase for biomacromolecule separations on analytical and preparative scales have been developed by Marcus research group. The combination of the fiber micro- and macro-structures and in-column orientation allows …

    clemson Repository record for Development of Capillary-Channeled Polymer (C-CP) Fiber as Stationary Phase for Biological Sample Application (opens in a new tab)

  6. Development of Functionalized Capillary-Channeled Polymer (C-CP) Fibers as Stationary Phase for Affinity Chromatography

    … University) has investigated the potentials of capillary-channeled polymer (C-CP) fibers for the past 15 years. These fibers are characterized by eight capillary channels running down the length of the fiber, allowing the fibers to interdigitate to form well-aligned micrometer-sized channels …

    clemson Repository record for Development of Functionalized Capillary-Channeled Polymer (C-CP) Fibers as Stationary Phase for Affinity Chromatography (opens in a new tab)

  7. SURFACE MODIFICATIONS OF CAPILLARY-CHANNELED POLYMER (C-CP) FIBERS FOR APPLICATIONS IN HIGHLY SELECTIVE SEPARATIONS

    … Recent research has looked to non-porous polymeric materials as stationary phases in HPLC to overcome these challenges. Specifically, fibrous based polymer stationary phases exhibit significant benefits for macromolecules that include improved mass transfer, decreased operating pressures, …

    clemson Repository record for SURFACE MODIFICATIONS OF CAPILLARY-CHANNELED POLYMER (C-CP) FIBERS FOR APPLICATIONS IN HIGHLY SELECTIVE SEPARATIONS (opens in a new tab)

  8. FUNDAMENTAL ASPECTS OF SMALL MOLECULES AND MACROMOLECULES ON POLY(ETHYLENE TEREPHTHALATE) CAPILLARY-CHANNELED POLYMER FIBERS

    … high performance liquid chromatography (HPLC). Polymeric stationary phases have gained popularity due to their ability to be employed over a large pH range and because they are more chemically robust when compared to silica based phases. Capillary-channeled polymer (C-CP) fibers are an …

    clemson Repository record for FUNDAMENTAL ASPECTS OF SMALL MOLECULES AND MACROMOLECULES ON POLY(ETHYLENE TEREPHTHALATE) CAPILLARY-CHANNELED POLYMER FIBERS (opens in a new tab)

  9. CHARACTERIZATION OF CAPILLARY-CHANNELED POLYMER FIBERS AS STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY OF MACROMOLECULES

    Capillary-channeled polymer (C-CP) fibers are being developed and characterized as high-performance liquid chromatography (HPLC) stationary phases for reversed-phase separations of proteins. Conventional porous phases are not well suited for separating large macromolecules due to the slow …

    clemson Repository record for CHARACTERIZATION OF CAPILLARY-CHANNELED POLYMER FIBERS AS STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY OF MACROMOLECULES (opens in a new tab)

  10. SURFACE MODIFICATIONS OF CAPILLARY-CHANNELED POLYMER (C-CP) FIBER STATIONARY PHASES: IMPROVING THE EFFICIENCY OF HIGHLY SELECTIVE ANALYTE SEPARATIONS

    … have been developed. Specifically, fiber based polymer stationary phases show great promise as stationary phases for protein separations. The Marcus laboratory has investigated capillary-channeled polymer (C-CP) fibers as an HPLC stationary phase for the past decade. These novel shaped fibers …

    clemson Repository record for SURFACE MODIFICATIONS OF CAPILLARY-CHANNELED POLYMER (C-CP) FIBER STATIONARY PHASES: IMPROVING THE EFFICIENCY OF HIGHLY SELECTIVE ANALYTE SEPARATIONS (opens in a new tab)

  11. Hydrodynamic Evaluation and Characterization of Capillary Channeled Polymer (C-CP) Fibers as a Stationary Phase in HPLC of Macromolecules

    … silica, polysaccharides, monoliths, and organic polymers. Although porous silica phases are very effective in small molecule separations, they suffer from certain drawbacks including pH stability, chemical robustness, high backpressure, and slow mass transfer for macromolecule separations. Thus, …

    clemson Repository record for Hydrodynamic Evaluation and Characterization of Capillary Channeled Polymer (C-CP) Fibers as a Stationary Phase in HPLC of Macromolecules (opens in a new tab)

  12. Incorporation of Capillary-Channeled Polymer (C-CP) Fibers Into Micropipette Tips For Solid Phase Extraction With Applications in Bioanalysis

    … to MS; thereby improving signal and sensitivity. Capillary channel polymer (C-CP) fibers have been used for reversed phase separations of proteins with a number of positive attributes realized.9 The highly efficient fluid transport, low material cost, wide range of chemical diversity, and robust …

    clemson Repository record for Incorporation of Capillary-Channeled Polymer (C-CP) Fibers Into Micropipette Tips For Solid Phase Extraction With Applications in Bioanalysis (opens in a new tab)

  13. Rapid Isolation and Quantification of Exosome and Lentivirus by Hydrophobic Interaction Chromatography on a Polyester Capillary-Channeled Polymer Fiber Stationary Phase

    … Marcus and coworkers have successfully employed capillary-channeled polymer (C-CP) fibers as the stationary phase for protein and IgG separations via reversed-phase (RP), ion exchange (IEX), hydrophobic interaction (HIC), and affinity chromatography. In this study, we have used the C-CP column …

    clemson Repository record for Rapid Isolation and Quantification of Exosome and Lentivirus by Hydrophobic Interaction Chromatography on a Polyester Capillary-Channeled Polymer Fiber Stationary Phase (opens in a new tab)

  14. Evaluation of Next Generation Capillary-Channeled Polymer Fibers and the Implementation of C-CP Fiber Modification Modalities on Non-Fiber Substrates

    … has been leveraging the continued advances of Capillary-Channeled Polymer (C-CP) fibers in an attempt to meet the demand of high throughput biomarcomolecule chromatography. Separation mechanisms studied include: ion-exchange (IC), reversed phase (RP), affinity, hydrophobic interaction …

    clemson Repository record for Evaluation of Next Generation Capillary-Channeled Polymer Fibers and the Implementation of C-CP Fiber Modification Modalities on Non-Fiber Substrates (opens in a new tab)

  15. Isolation and Characterization of Extracellular Vesicles from Various Biological Matrices using Capillary-Channeled Polymer (C-CP) Fiber Solid-Phase Extraction Spin-Down Tips

    … interaction chromatography (HIC) workflow on a capillary-channeled polymer (C-CP) fiber spin-down tip. Here, EVs are isolated from several biofluid sources, including mock biofluid matrices, clinical patient biofluid samples, cellular milieu from mammalian and amoeba cell lines, and over 20 …

    clemson Repository record for Isolation and Characterization of Extracellular Vesicles from Various Biological Matrices using Capillary-Channeled Polymer (C-CP) Fiber Solid-Phase Extraction Spin-Down Tips (opens in a new tab)

  16. Biotinylated Protein Capture and Tween-20 Assisted Exosome Isolations via Capillary Chanelled Polymer Fiber

    … and colleagues have led the advancement of capillary-channeled polymer (C-CP) fiber stationary phases for biomacromolecule separations, including proteins and nanovesicles. These stationary phases offer notable advantages, including low cost ($5/column), straightforward column fabrication, …

    clemson Repository record for Biotinylated Protein Capture and Tween-20 Assisted Exosome Isolations via Capillary Chanelled Polymer Fiber (opens in a new tab)

  17. Development of Extracellular Vesicle Isolation and Model Systems Toward Early Ovarian Cancer Diagnostics

    … Here poly(ethylene terephthalate) (PET) capillary channeled polymer (C-CP) fibers employing an HIC protocol are investigated as a novel exosome isolation method and a quick, inexpensive, and easy-to-use platform for OC diagnosis. The cell model system, immunoaffinity protocols, and …

    clemson Repository record for Development of Extracellular Vesicle Isolation and Model Systems Toward Early Ovarian Cancer Diagnostics (opens in a new tab)

Page 1 of 2