  1. Cardiac Gating Methods for Coronary Magnetic Resonance Angiography

    … span multiple heartbeats. Typically, to reduce cardiac motion artifacts, electrocardiogram (ECG) gating is used to synchronize data acquisition windows to diastasis periods. Gating errors may cause vessel blurring by unintentionally triggering the scanner to acquire image data during periods of …

    toronto-retro Repository record for Cardiac Gating Methods for Coronary Magnetic Resonance Angiography (opens in a new tab)

  2. Cardiac radiosurgery motion management – investigation of regional myocardial motion and cardiac gating

    … life-threatening, leading to severely diminished cardiac output or sudden cardiac death. VT predominantly arises from scarred myocardium, where re-entrant electrical circuits cause continuous re-excitation. Cardiac radiosurgery is a non-invasive treatment for VT, where a linear accelerator is used …

    ubc Repository record for Cardiac radiosurgery motion management – investigation of regional myocardial motion and cardiac gating (opens in a new tab) Download PDF for Cardiac radiosurgery motion management – investigation of regional myocardial motion and cardiac gating (opens in a new tab)

  3. Motion Detection with Ultrasound for Use in Magnetic Resonance Imaging

    … throughout the scan. Of course the patient's cardiac and respiratory systems function as they normally would. If this involuntary motion is not compensated, then the image contains noncoherent noise that is superimposed over the motionless anatomy. Due to the manner in which data is collected, …

    marquette Repository record for Motion Detection with Ultrasound for Use in Magnetic Resonance Imaging (opens in a new tab)

  4. Cardiac Tissue Characterization Following Myocardial Infarction Using Magnetic Resonance Imaging

    … resonance imaging (MRI) methods to characterize cardiac tissue with myocardial infarction (MI). Wall motion imaging (for visualizing myocardial contraction) and viability imaging (to identify MI) are two components of cardiac tissue characterization used for prognosis and treatment planning. …

    toronto-retro Repository record for Cardiac Tissue Characterization Following Myocardial Infarction Using Magnetic Resonance Imaging (opens in a new tab)

  5. Cardiac Imaging in Mice With Micro-Computed Tomography: An Assessment

    … for anesthetic depth and duration. Following cardiac gating qualification,10 mice (WT: n=7, FAPKO: n=3) were removed from the data set due to high quantities of raw projections with ventricular displacements in the micro-CT reconstructions. Across all groups, ESV and HR measured by micro-CT …

    south-carolina Repository record for Cardiac Imaging in Mice With Micro-Computed Tomography: An Assessment (opens in a new tab)

  6. Detection and prediction of cardiac quiescence for computed tomography coronary angiography

    … angiography (CTCA) imaging by developing gating techniques based on signals derived from cardiac motion, rather than the currently used electrocardiogram (ECG), to more reliably trigger data acquisition during periods of cardiac quiescence. Because the ECG is an indication of electrical …

    gatech Repository record for Detection and prediction of cardiac quiescence for computed tomography coronary angiography (opens in a new tab)

  7. Variability of DTI Values in the Human Cervical and Lumbar Spinal Cord

    … and absence of a correctional measure for cardiac-induced motion called 'cardiac gating'. Tissue discriminability was found to be greatest in the cervical cord. Second, DTI results were subjected to two classification algorithms and compared with known anatomy to assess tissue …

    queens Repository record for Variability of DTI Values in the Human Cervical and Lumbar Spinal Cord (opens in a new tab)

  8. The Influence of Timing on the Hemodynamic Effects of Compression Devices and Development of Sensor Driven Timing Mechanisms

    … this thesis were to assess and improve a custom cardiac gated compression (CGC) system that times compressions based on an individual’s heartrate so as to only apply compressions during the diastolic phase of the cardiac cycle. A comparative performance assessment was done by measuring the …

    waterloo Repository record for The Influence of Timing on the Hemodynamic Effects of Compression Devices and Development of Sensor Driven Timing Mechanisms (opens in a new tab)

  9. Development of a multimodal framework for cardiac computed tomography gating

    … from limited temporal resolution resulting in cardiac motion artifacts. Therefore, it is crucial to obtain CTA data when the cardiac motion is minimal within the cardiac cycle, known as the cardiac quiescence. The objective of this work is to improve the diagnostic quality and reduce radiation …

    gatech Repository record for Development of a multimodal framework for cardiac computed tomography gating (opens in a new tab)

  10. Advancing Magnetic Resonance Spectroscopy and Endoscopy with Prior Knowledge

    … motion, which can necessitate time-consuming cardiac gating techniques. Here, we develop acceleration techniques based on the compressed sensing theory, and un-gated motion compensation strategies using projection shifting, to effectively produce faster motion-suppressed MRI endoscopy.

    jhu Repository record for Advancing Magnetic Resonance Spectroscopy and Endoscopy with Prior Knowledge (opens in a new tab)

  11. Evaluierung und Einfluss von Gating-Methoden für klinische Feldstärken und Ultra-Hochfeld-Magnetresonanztomographie

    … kardialen Zyklus mit der Bildakquise (kardiales Gating) spielt in der kardiovaskulären Magnetresonanztomographie (CMR) eine große Rolle. Das dafür häufig verwendete Elektrokardiogram (EKG) unterliegt in der Umgebung des Magnetresonanztomographen häufig multiplen Störfaktoren. Insbesondere die …

    fu-berlin Repository record for Evaluierung und Einfluss von Gating-Methoden für klinische Feldstärken und Ultra-Hochfeld-Magnetresonanztomographie (opens in a new tab)