Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 70 for “"Cardiography"”.

  1. Impedance cardiography in the elderly

    Experience gained by performing 1250 impedance cardiograms in 362 elderly subjects has shown that the technique is simple, noninvasive and highly reproducible; it lends itself to the investigation of cardiovascular problems in the elderly. Minor modifications to the method, as applied to the …

    glasgow Download PDF for Impedance cardiography in the elderly (opens in a new tab)

  2. An Evaluation of Ensemble Average As Applied to Impedance Cardiography

    Impedance cardiographic data measurements made by a standard hand-digitizing method were compared with those made by a new ensemble averaging technique. Five healthy, young males were monitored in the supine and seated positions during rest and two stages of bicycle exercise. We found ensemble …

    marquette Repository record for An Evaluation of Ensemble Average As Applied to Impedance Cardiography (opens in a new tab)

  3. Study of the value of phono cardiography in clinical medicine

    … view - firstly, to master the technique of phonocardiography; secondly, to decide whether accurate visual records of the heart sounds could be made with reasonable ease; and, finally, to decide what actual value such recordings might have for the practising physician.

    edinburgh Repository record for Study of the value of phono cardiography in clinical medicine (opens in a new tab)

  4. Evaluation of impedance cardiography (ICG) for assessing hemodynamic parameters in Fontan patients

    Introduction: Hemodynamic assessment using currently available methods is particularly challenging in the Fontan population. Patients with Fontan circulation are generally described to have chronically low cardiac output (CO) and high central venous pressure (CVP). Reduced exercise capacity is …

    manitoba Repository record for Evaluation of impedance cardiography (ICG) for assessing hemodynamic parameters in Fontan patients (opens in a new tab)

  5. Using impedance cardiography to examine changes in hemodynamic parameters during heart rate biofeedback

    … challenge, as HR, blood pressure, and impedance cardiography-derived measures were recorded. During the training sessions, the FB+ group received HR feedback and the FB-- group was not provided with HR feedback while playing the videogame. Results revealed that those in de FB+ group demonstrated …

    wvu Repository record for Using impedance cardiography to examine changes in hemodynamic parameters during heart rate biofeedback (opens in a new tab)

  6. Accuracy of impedance cardiography for the measurement of stroke volume and hemodynamic factors affecting this method

    This document only includes an excerpt of the corresponding thesis or dissertation. To request a digital scan of the full text, please contact the Ruth Lilly Medical Library's Interlibrary Loan Department (rlmlill@iu.edu).

    iupui Repository record for Accuracy of impedance cardiography for the measurement of stroke volume and hemodynamic factors affecting this method (opens in a new tab)

  7. Analysis of defibrillation efficacy and investigation of impedance cardiography with finite element models incorporating anisotropic myocardium

    … the measured impedance change in impedance cardiography using realistic diastolic and systolic human thorax models. The results show that ventricular contraction, the only factor that increases systolic impedance, has a larger effect than the resulting expansion of major vessels and decrease …

    washington Repository record for Analysis of defibrillation efficacy and investigation of impedance cardiography with finite element models incorporating anisotropic myocardium (opens in a new tab)

  8. The utility of bioimpedance cardiography in assessing the influence of obstructive sleep apnea hypopnea syndrome on cardiac function

    … apnea event using a new improved bioimpedance cardiography system. Methods: Fifteen apparently healthy males were tested on three different days in a protocol requiring their performance of two 15 sec and two 30 sec forced and sustained inspiratory efforts against a closed epiglottis (Müeller …

    vt Repository record for The utility of bioimpedance cardiography in assessing the influence of obstructive sleep apnea hypopnea syndrome on cardiac function (opens in a new tab)

  9. Fetal phonocardiography

    … being used to detect the fetal heart rate. Phonocardiography, abdominal electrocardiography and ultrasound cardiography are the three most commonly used techniques for external fetal cardiography. This thesis describes an application of adaptive signal processing to fetal phonocardiography for …

    njit Repository record for Fetal phonocardiography (opens in a new tab)

  10. Congenital heart disease in the paediatric age-group

    … discussed in detail, and the results of electro- cardiography and X -ray investigation presented. The results of cardiac catheterization are given in certain cases. The diagnosis was tested by each or all of these methods, and, too often by autopsy. Further proof has accrued since the completion …

    edinburgh Repository record for Congenital heart disease in the paediatric age-group (opens in a new tab)

  11. Συσχέτιση ολικών περιφερικών αντιστάσεων με την λειτουργία της αριστερής κοιλίας σε ασθενείς με χρόνια νεφρική ανεπάρκεια και θεραπείες υποκατάστασης

    … others. All patients underwent a complete echocardiography study for determining left ventricular structural and functional status according to ASE guidelines. Systemic vascular resistance was studied by various methods although it was mainly registered by means of ultrasonography (aortic pulse …

    greece Repository record for Συσχέτιση ολικών περιφερικών αντιστάσεων με την λειτουργία της αριστερής κοιλίας σε ασθενείς με χρόνια νεφρική ανεπάρκεια και θεραπείες υποκατάστασης (opens in a new tab)

  12. Cardiopulmonary responses to acute hypoxia and exercise in relation to the angiotensin converting enzyme insertion/deletion gene polymorphism

    … during hypoxia and exercise using bioimpedance cardiography. These studies were performed simultaneously with the cardiopulmonary exercise tests and included 31 subjects. Similar analyses were performed on cardiac output variables between normoxia and hypoxia. The repeatability of the steady …

    glasgow Repository record for Cardiopulmonary responses to acute hypoxia and exercise in relation to the angiotensin converting enzyme insertion/deletion gene polymorphism (opens in a new tab) Download PDF for Cardiopulmonary responses to acute hypoxia and exercise in relation to the angiotensin converting enzyme insertion/deletion gene polymorphism (opens in a new tab)

  13. Device, Method, and Algorithm to Assess Changes in Cardiac Output via Intracardiac Impedance Monitoring

    … device. The principles of traditional impedance cardiography, an established cardiac output monitoring technique in practice for over fifty years, have been adapted to incorporate a leadless artificial cardiac pacemaker, an implantable medical device contained entirely within the heart. This …

    portland-state Repository record for Device, Method, and Algorithm to Assess Changes in Cardiac Output via Intracardiac Impedance Monitoring (opens in a new tab)

  14. Resiliency and Autonomic Control of Cardiac Responses to Stress

    … activation along a continuum of threat. Electrocardiography and impedance cardiography were collected before, during, and after these tasks to assess changes in autonomic functioning. Results from multiple regression analyses indicated that high levels of EC predicted increased vagal control …

    vt Repository record for Resiliency and Autonomic Control of Cardiac Responses to Stress (opens in a new tab)

  15. Μελέτη των αλλοιώσεων μικρών και μεγάλων αγγείων σε ασθενείς με ρευματοειδή αρθρίτιδα

    … blood pressure measurement and impedance cardiography were applied. 10-year risk of general cardiovascular disease was estimated from the Framingham Heart Study. Galectin-3 levels were measured in serum samples with ELISA.Patients with RA, compared to controls, presented significantly …

    greece Repository record for Μελέτη των αλλοιώσεων μικρών και μεγάλων αγγείων σε ασθενείς με ρευματοειδή αρθρίτιδα (opens in a new tab)

  16. Autonomic Markers of Visual Awareness

    … visual detection, using a combination of electrocardiography (ECG), impedance cardiography (ICG) and pupillometry to examine cardiac autonomic functions, namely heart rate, the high-frequency component of heart rate variability (HRV), pre-ejection period (PEP) and change in pupil area. My studies …

    houston Repository record for Autonomic Markers of Visual Awareness (opens in a new tab)

Page 1 of 4