Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 44 for “"Cardiovascular applications"”

  1. Purinergic Hydrogels for Cardiovascular Applications

    Despite great advances, ischemic cardiovascular disease is still the leading cause of morbidity and mortality, and novel interventions are needed to improve outcomes. The best current treatment for ischemia, rapid reperfusion via percutaneous coronary intervention, causes subsequent injury due to …

    gatech Repository record for Purinergic Hydrogels for Cardiovascular Applications (opens in a new tab)

  2. Methacrylic Terpolymer Biomaterials for Cardiovascular Applications

    … a novel polymeric biomaterial system for use in cardiovascular applications. Specifically, our goal in this work was to develop a material which fosters a confluent and functioning endothelial cell layer in hopes of creating a blood compatible interface. Once synthesized and characterized, the …

    ohiolink Repository record for Methacrylic Terpolymer Biomaterials for Cardiovascular Applications (opens in a new tab)

  3. A Bioinspired Multifunctional Nanomatrix for Cardiovascular Applications

    … Stents are a common therapeutic device for cardiovascular diseases that have undergone incrementally developmental changes over the last two decades. However, there are concerns about in-stent restenosis with bare metal stents and incomplete endothelialization, late stent thrombosis, and …

    uab Repository record for A Bioinspired Multifunctional Nanomatrix for Cardiovascular Applications (opens in a new tab)

  4. Poly(beta-amino esters) for cardiovascular applications

    Abdominal aortic aneurysms are a leading cause of death in the U.S. where 14,000 people die from aneurysm rupture and 178,000 are diagnosed each year. A novel alternative treatment for abdominal aortic aneurysms has been proposed, where a biodegradable polymer scaffold is photopolymerized in situ …

    gatech Repository record for Poly(beta-amino esters) for cardiovascular applications (opens in a new tab)

  5. 3D-printed polymeric bioresorbable stents for cardiovascular applications

    … approach to generate everolimus-eluting BRS for cardiovascular applications. A Design of Experiment was conducted to determine the parameters necessary for optimal homogeneous coating with high specific surface. Drug loading was achieved either encapsulated in the struts of the stent or in an …

    barcelona Repository record for 3D-printed polymeric bioresorbable stents for cardiovascular applications (opens in a new tab)

  6. Novel functionalized and patterned surfaces for cardiovascular applications

    Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows very good clinical results, however, it exists non negligible cases of in stent restenosis (ISR) and late stent thrombosis …

    barcelona Repository record for Novel functionalized and patterned surfaces for cardiovascular applications (opens in a new tab)

  7. Hemocompatibility Assessment of 3C-SiC for Cardiovascular Applications

    … Silicon (Si), the leading material in biosensing applications. Silicon carbide (SiC) is a hard, chemically robust material, very well suited for harsh environment applications, and has been suggested to have very good biocompatibility. Additionally, SiC in its amorphous form, has been used as a …

    usf Repository record for Hemocompatibility Assessment of 3C-SiC for Cardiovascular Applications (opens in a new tab)

  8. Polycaprolactone nanowire surfaces as interfaces for cardiovascular applications

    Cardiovascular disease is the leading killer of people worldwide. Current treatments include organ transplants, surgery, metabolic products and mechanical/synthetic implants. Of these, mechanical and synthetic implants are the most promising. However, rejection of cardiovascular implants continues …

    colostate Repository record for Polycaprolactone nanowire surfaces as interfaces for cardiovascular applications (opens in a new tab)

  9. Photoacoustic image guidance and tissue characterization in cardiovascular applications

    Collectively, cardiovascular diseases continue to be the leading cause of death, across nations and across decades. Improved diagnostic imaging methods offer promise to alleviate the morbidity associated with these diseases. Photoacoustic (PA) imaging is one such method, poised to make a …

    texas Repository record for Photoacoustic image guidance and tissue characterization in cardiovascular applications (opens in a new tab)

  10. Characterisation of polyvinyl alcohol hydrogels modified with chitosan for cardiovascular applications

    The use of Polyvinyl Alcohol (PVA) hydrogels combined with chitosan as a vascular tissue substitute for in vitro vascular cell culture studies was investigated. Hydrogels possess many characteristics that can be controlled and adjusted during the fabrication processes, such as tissue-like …

    dcu Repository record for Characterisation of polyvinyl alcohol hydrogels modified with chitosan for cardiovascular applications (opens in a new tab)

  11. Synthesis and characterization of an injectable copolymer hydrogel for cardiovascular applications

    … hydrogel was developed that may be suitable for cardiovascular applications. This material consists of a triblock copolymer of poly(propylene fumarate) and poly(ethylene glycol). The first part of this work involved characterizing the kinetics of the poly(propylene fumarate) (PPF) reaction using …

    rice Repository record for Synthesis and characterization of an injectable copolymer hydrogel for cardiovascular applications (opens in a new tab)

  12. Nanostructured PVDF-TrFE based piezoelectric pressure sensors on catheter for cardiovascular applications

    … which indicates the physiological state of the cardiovascular system. Current technology relies on fluid filled catheter coupled to remote transducers to measure endovascular pressures and gradients. The fluid filled catheters are bulky, inherently inaccurate due to the tubing mechanical …

    texas Repository record for Nanostructured PVDF-TrFE based piezoelectric pressure sensors on catheter for cardiovascular applications (opens in a new tab)

  13. Development of poly(propylene fumarate-co-ethylene glycol): An injectable, biodegradable implant for cardiovascular applications

    … PEG, was fabricated and evaluated for use as a cardiovascular stent to prevent reclosure of the vessel lumen following balloon angioplasty. This copolymer has been fabricated in a block configuration with two to three homopolymer units in series through a transesterification reaction between the …

    rice Repository record for Development of poly(propylene fumarate-co-ethylene glycol): An injectable, biodegradable implant for cardiovascular applications (opens in a new tab)

  14. Elastin-like Polypeptide Enriched Surfaces for Cardiovascular Applications through the use of Bioactive Fluorinated Surface Modifiers

    … (ELPs) make them a suitable option for these applications. In this thesis, ELP surface modification has been achieved through the use of elastin cross-linking peptide bioactive fluorinated surface modifiers (ECP-BFSMs). The synthesis of these low molecular weight fluorinated additives was …

    toronto-retro Repository record for Elastin-like Polypeptide Enriched Surfaces for Cardiovascular Applications through the use of Bioactive Fluorinated Surface Modifiers (opens in a new tab)

  15. THE USE OF NANOSTRUCTURED 316L STAINLESS STEEL FOR ORTHOPEDIC AND CARDIOVASCULAR APPLICATIONS: FABRICATION, CHARACTERIZATION, AND IN VITRO CELLULAR INTERACTIONS

    … commonly-used implant materials in biomedical applications due to its ideal mechanical properties, acceptable biocompatibility, and low cost. However, the bioinert nature of 316L SS led to limited osteointegration in orthopedic applications, and poor endothelization in cardiovascular …

    metu Repository record for THE USE OF NANOSTRUCTURED 316L STAINLESS STEEL FOR ORTHOPEDIC AND CARDIOVASCULAR APPLICATIONS: FABRICATION, CHARACTERIZATION, AND IN VITRO CELLULAR INTERACTIONS (opens in a new tab)

  16. Computer simulations of coronary blood flow through a constriction

    … to further evaluate fluid characteristics for cardiovascular applications. Reasonable agreement occurs between computational and experimental data. This work is done in preparation for future research to develop a microelectromechanical system capable of monitoring blood flow and aiding in …

    nps Repository record for Computer simulations of coronary blood flow through a constriction (opens in a new tab)

Page 1 of 3