Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"Cardiovascular devices"”

  1. Characterizing Polymers for Cardiovascular Devices

    Abdominal aortic aneurysm (AAA) occurs in developed nations. The current treatment, endovascular aneurysm repair (EVAR), while successful, has shortcomings. A solution to the concerns with EVAR is a polymeric endo-aortic paving (PEAP). Our goal is to further develop this treatment for AAA. We …

    arizona-thes Repository record for Characterizing Polymers for Cardiovascular Devices (opens in a new tab)

  2. Modeling and numerical simulation of implantable cardiovascular devices

    Cette thèse, réalisée dans le cadre du projet Mivana, est consacrée à la modélisation et à la simulation numérique de dispositifs cardiaques implantables. Ce projet est mené par les start-up Kephalios et Epygon, concepteurs de solutions chirurgicales non invasives pour le traitement de la …

    star-france Repository record for Modeling and numerical simulation of implantable cardiovascular devices (opens in a new tab)

  3. The effects of different cardiovascular devices on carotid and aortic baroreceptors

    … physiological changes result. Several medical devices have been developed to treat and manage cardiovascular diseases that are affected by blood pressure dysregulation. A significant portion of devices have their mechanistic application at locations at or near the aortic and carotid …

    bu Repository record for The effects of different cardiovascular devices on carotid and aortic baroreceptors (opens in a new tab)

  4. Polylactic acid based materials and nanostructured multilayers for cardiovascular devices and wound healing

    … This thesis work was focused on materials for cardiovascular applications, with reference to stenting. However, the possible transfer of the materials prepared and the experimental approach developed in vascular tissue engineering and wound healing was investigated. Therefore, model aminolysed …

    poli-torino Repository record for Polylactic acid based materials and nanostructured multilayers for cardiovascular devices and wound healing (opens in a new tab)

  5. A Framework of Flow Models for the Development and Testing of Cardiovascular Devices

    Cardiovascular disease (CVD) is the leading cause of death worldwide and its treatment continues to improve due to the advancement of innovative cardiovascular medical devices. In vitro and in silico models serve to replicate the in vivo environment for the development and testing of these devices …

    arkansas Repository record for A Framework of Flow Models for the Development and Testing of Cardiovascular Devices (opens in a new tab)

  6. Shear layer instabilities and flow-acoustic coupling in valves: application to power plant components and cardiovascular devices

    In the first part of this dissertation, the phenomenon of self-sustained pressure os-cillations due to the flow past a circular, axisymmetric cavity, associated with inline gate valves, was investigated. In many engineering applications, such as flows through open gate valves, there exists …

    uvic Repository record for Shear layer instabilities and flow-acoustic coupling in valves: application to power plant components and cardiovascular devices (opens in a new tab)

  7. A Multiphysics Simulation of a Coronary Artery

    … a model can be adapted to guide the design of cardiovascular devices.

    calpoly Repository record for A Multiphysics Simulation of a Coronary Artery (opens in a new tab)

  8. Development of a Tubular Biological Tissue-Engineered Heart Valve with Growth Potential

    This thesis investigates tissue-engineered cardiovascular devices for pediatric patients and their function and growth potential in preclinical testing. Specifically, engineered tissue tubes were fabricated by entrapping dermal fibroblasts in a fibrin gel and allowing them to replace it with …

    umn Repository record for Development of a Tubular Biological Tissue-Engineered Heart Valve with Growth Potential (opens in a new tab)

  9. Design and Development of a Systemic Mock Circulation Loop with a Novel Beating Left Ventricular Simulator

    … used as a mechanical representation of the human cardiovascular system for in vitro testing of most cardiovascular devices. Thus, MCLs are essential to most of the cardiac device designs as a testbed. Cardiac device design procedures generally adopt mock circulatory systems before advancing to …

    ttu Repository record for Design and Development of a Systemic Mock Circulation Loop with a Novel Beating Left Ventricular Simulator (opens in a new tab)

  10. Aplicações e desafios em biomateriais poliméricos para fabricação de corações artificiais e dispositivos cardiovasculares

    … review of the main polymers used in implantable cardiovascular devices, discussing their structural properties, chemical stability, biological response, and future perspectives regarding their clinical application. Relevant cases of synthetic heart valves and artificial hearts based on advanced …

    brazil-ufscar Repository record for Aplicações e desafios em biomateriais poliméricos para fabricação de corações artificiais e dispositivos cardiovasculares (opens in a new tab)

  11. CHARACTERIZATION AND BIOLOGICAL EVALUATION OF ABSORBABLE POLYMERS

    The use of absorbable polymers in medical devices has garnered increasing interest due to their applications in sutures, cardiovascular devices, orthopedic fixation devices, and surgical mesh. However, evaluating these polymers presents significant challenges as their materials properties and the …

    jhu Repository record for CHARACTERIZATION AND BIOLOGICAL EVALUATION OF ABSORBABLE POLYMERS (opens in a new tab) Embargoed until 2028-12-01

  12. An innovative approach to cardiovascular flow simulators : validation of an air-based study

    Cardiovascular disease (CVD) is the leading cause of illness worldwide, yet a comprehensive understanding of the underlying physiological processes remains elusive. Despite rapid advancements in technology, methods for studying and testing devices and therapies still have significant room for …

    ubc Repository record for An innovative approach to cardiovascular flow simulators : validation of an air-based study (opens in a new tab)

  13. CHARACTERIZATION AND BIOLOGICAL EVALUATION OF ABSORBABLE POLYMERS

    The use of absorbable polymers in medical devices has garnered increasing interest due to their applications in sutures, cardiovascular devices, orthopedic fixation devices, and surgical mesh. However, evaluating these polymers presents significant challenges as their material properties and the …

    jhu Repository record for CHARACTERIZATION AND BIOLOGICAL EVALUATION OF ABSORBABLE POLYMERS (opens in a new tab) Embargoed until 2026-12-01

  14. Analysis and experiments on flow-induced hemolysis.

    … blood pumps, artificial hearts and other cardiovascular devices, is one of the major concerns during the design and use of cardiovascular or blood-processing extracorporeal devices. A non-invasive experimental method which does not interfere directly with red blood cells was designed to …

    louisville Repository record for Analysis and experiments on flow-induced hemolysis. (opens in a new tab)

  15. Stabilization of Vascular Elastin by Treatment with Tannins

    … of the extracellular matrix that endows cardiovascular tissue with the ability to extend and recoil repetitively. It has been shown that elastin may be vulnerable to enzymatic degradation and calcification in certain pathological cases. As a result, elastin degeneration may be associated …

    clemson Repository record for Stabilization of Vascular Elastin by Treatment with Tannins (opens in a new tab)

  16. Permeability of a segmented polyether-polyurethane to decamethyltetrasiloxane into bovine blood

    … HeartSaver VAD™ currently being developed by the Cardiovascular Devices Division of the University of Ottawa Heart Institute and World Heart Corporation is an innovative, new design which overcomes many of the technical challenges inherent to previous VAD designs. The current design concept uses …

    carleton Repository record for Permeability of a segmented polyether-polyurethane to decamethyltetrasiloxane into bovine blood (opens in a new tab)

  17. Model-directed design of electrospun vascular grafts and heart valves

    … clinical need to develop polymeric materials for cardiovascular devices to overcome the limited availability of autografts and limited durability of bioprosthetics. However, polymeric devices continue to suffer from a high rate of failure due to adverse tissue responses and limited durability as …

    texas Repository record for Model-directed design of electrospun vascular grafts and heart valves (opens in a new tab)

  18. Development of a Multilayer Vascular Graft with Targeted Cellular Interactions and Improved Mechanical Properties

    … inner layer as well as other blood contacting devices. We further improved the graft by increasing outer layer compliance matching and elucidated the intrinsic relationship between compliance mismatch and the development of intimal hyperplasia. We first fabricated grafts of increasing …

    tamu Repository record for Development of a Multilayer Vascular Graft with Targeted Cellular Interactions and Improved Mechanical Properties (opens in a new tab)

Page 1 of 2