Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 514 for “"Cast-in-Place"”.
-
Quality Assurance of Cast-in-Place Foundation Elements
Construction of cast-in-place concrete deep foundation elements is a common practice, yet performed almost entirely blind, leaving uncertainty in the quality of the as-built, below-ground element. This dissertation focuses on three quality assurance aspects of cast-in-place foundations: an …
-
Structural capacity of steel tubular cast-in-place piling
Steel tubular cast-in-place pilings are used throughout the country for many different project types. These piles are a closed-end pipe with varying wall thicknesses and outer diameters, that are driven to depth and then the core is filled with concrete. These piles are typically used for smaller …
-
The design of a cast-in-place reinforced concrete silo
Thesis (B.S.)--Michigan State College of Agriculture and Applied Science, 1948
-
Earth shoring for cast-in-place and post tensioned bridge construction
<p>This thesis offers engineers, contractors, and planners a model for the design, selection, and construction of cast-in-place and post-tensioned concrete bridges. Concrete bridges have traditionally been built using conventional falsework to support the loads, but failures have sometimes occurred …
-
Behavior of the cast-in-place splice regions of spliced I-girder bridges
Spliced girder technology continues to attract attention due to its versatility over traditional prestressed concrete highway bridge construction. Relatively limited data is available in the literature, however, for large-scale tests of post-tensioned I-girders, and few studies have examined the …
-
Thermal & structural performance of a cast in place reinforced concrete balcony thermal break
… performance of a balcony thermal break when reinforced with carbon steel, stainless steel, or glass fiber reinforced polymer (GFRP). Thermal experimental testing was performed along with three-dimensional finite element modelling to quantify the heat transfer through each variation of the …
-
Friction values for cast-in-place concrete piles in a typical Winnipeg clay
Friction values for cast-in-place piles in a typical Winnipeg clay were studied. Shear conditions in the soil near a pile were simulated in the laboratory, using a direct shear apparatus and undisturbed samples of the clay were placed in contact with wet mortar. Softening of the clay due to soaking …
-
The Connection Behavior of Precast Prestressed Piles to Cast-In-Place Bent Caps
The state of South Carolina employs a unique connection detail between precast prestressed piles to cast in place bent caps. This detail is constructed by plainly embedding piles to a specified depth into bent caps. Typically in regions of high seismicity such as South Carolina connections between …
-
Enhancement of Shaft Capacity of Cast-in-Place Piles Using a Hook System
This research investigates an innovative approach to improve the shaft bearing capacity of cast-in-place pile foundations by utilizing passive inclusions (Hooks) that will be mobilized if movement occurs in pile system. An extensive experimental program was developed to study the shaft bearing …
-
Investigation of continuity in joints between precast and "cast in place" reinforced concrete members
The investigation dealt mainly with the shear transfer capacity of a joint between a precast concrete column and a cast-in-place concrete beam. Four reinforced concrete frames, each consisting of two columns and two beams, were cast, assembled and tested in a special loading frame. To obtain a …
-
Simplifying Cast-in-Place Joint Design Using ABC Pocket Connection Details in High Seismic Regions
Accelerated bridge construction (ABC) utilizes precast members to minimize on-site construction time, making it an appealing alternative to conventional cast-in-place (CIP) construction. The connections between these precast members are crucial as they must maintain structural integrity, and in …
-
Connection of modular steel beam precast slab units with cast-in-place closure pour slabs
Jointless bridges are advantageous in removing mechanical joints which are a known cause of bridge deterioration. Elimination of joints provides a smoother riding surface and removes the possibility of de-icing salts penetrating the deck and corroding the deck reinforcing and underlying bridge …
-
Evaluating mechanical and visco-elastic properties of self-consolidating concrete for cast-in-place bridges
Self-consolidating concrete (SCC) is highly flowable, non-segregating concrete that can spread into place, fill the formwork, and encapsulate the reinforcement without any mechanical consolidation (ACI 237). SCC was introduced as a more durable alternative to conventional vibrated concrete (CVC) in …
-
Prestressed PCBT Girders Made Continuous and Composite with a Cast-in-place Deck and Diaphragm
… prestressed PCBT girders made composite with a cast-in-place concrete deck and continuous over several spans through the use of continuity diaphragms. The current design procedure in AASHTO states that a continuity diaphragm is considered to be fully effective if a compressive stress develops in …
-
Evaluation of AASHTO Design Specifications for Cast-In-Place Continuous Bridge Deck Using Remote Sensing Technique
… research project concerns the construction, testing, and remote health monitoring of the first smart bridge structure in Florida, the East Bay bridge in Gibsonton, Hillsborough County. The East Bay Bridge is a four span, continuous, deck-type structure with a total length of 120' and width of …
-
Empirical Relationships Betweenload Test Data And Predicted Compression Capacity Of Augered Cast-in-place Piles In Predominantly
Augered Cast-In-Place (ACIP) Piles are used in areas were the loading from a superstructure exceeds the soil bearing capacity for usage of a shallow foundation. In Northwest Florida and along the Gulf Coast, ACIP piles are often utilized as foundation alternatives for multi-story condominium …
-
Structural Performance of Cast-In-Place Pipe Liners at Perforations and Ring Fractures in the Host Pipe
… is to evaluate the structural performance of Cast-In-Place Pipe (CIPP) liners for pressure pipes, around areas of deterioration in the host pipe, specifically perforations and ring fractures. To evaluate the liner behaviour around perforations in a host pipe, an investigation using finite …
-
Finite Element Analysis of the Connection Behavior of Precast Prestressed Piles to Cast-In-Place Bent Caps
Eighteen finite element models were built using ABAQUS FEA version 6.10 in order to perform a parametric study used to determine the connection behavior of precast prestressed pile to cast in place bent caps for various pile sizes and bent cap embedment depths. Current construction practice in …
-
Environmental Impacts of Prefabricated Construction: CO2 Emissions Comparison of Precast and Cast-In-Place Concrete Case Study
… While the use of prefabrication has certain advantages in terms of environmental impacts through material and time efficiency, it is not clear nor has enough data for the quantities and factors comparing the conventional methods. This study aims to review the characteristics of …
-
Experimental Assessment of the Shear Resistant Behaviour of Precast Concrete Beams with Top Cast-in-Place Concrete Slab
… el ahorro de costes derivados de la obra in situ y la mejora de la calidad y acabados, entre otros. En la construcción prefabricada de estructuras de ingeniería civil como puentes y edificios es frecuente el empleo de vigas prefabricadas de hormigón. La construcción con estas vigas …
Page 1 of 26