Probabilistic Calibration and Catheter Tracking with Robotic Systems
… and this often boils down to calibration and tracking. The dissertation begins with a robotic catheter tracking system and then focuses on calibration of robotic systems. The presentation first introduces a novel robotic catheter tracking system which uses an embedded active piezoelectric …
-
Real-Time Catheter Tracking and Adaptive Imaging for Interventional Cardiovascular MRI
… so that it includes the important anatomy and/or catheter tip. Similarly, the multitude of adjustable MR parameters that control image properties like tissue contrast, spatial resolution, and temporal resolution also need to be updated intra-procedurally.</p> <p>This research addresses these …
-
MR-Guided Assessment and Management of Ventricular Tachycardia
… In electrophysiology (EP), radiofrequency (RF) catheter ablation combined with cardioverter-defibrillator implantation is a first-line action to manage ventricular VT. Unfortunately, this therapy is known to have sub-optimal success rates in a large number of patients because of difficulties to …
-
Accelerating MR Neuroimaging of Stroke Using Sparse Acquisition Coupled with Nonlinear Reconstruction Techniques
… For treatment, I describe an enhanced passive MR catheter tracking approach that enables continuous monitoring of the catheter during endovascular procedures. And finally, with regards to stroke prevention, I present a novel imaging technique for assessing atherosclerosis in carotid arteries. In …
-
'ACOUSTO-OPTIC SENSING FOR SAFE MRI PROCEDURES'
… resonance imaging (MRI). This is achieved by tracking interventional devices, such as guidewires and catheters during interventional MRI procedures, and by measuring the radio frequency (RF) field to assess RF safety of patients with implants, such as pacemakers, during diagnostic MRI. The …
-
Integration of Actuation, Imaging, and Control of a Magnetically Actuated, Magnetic Resonance Imaging-Guided Robotic Catheter
<p>Catheter ablation is an established treatment for refractory arrhythmia. Robotic catheters operating under MRI guidance may offer enhanced control, visualization, and safety. Catheter actuation with current-carrying microcoils is fast and responsive. However, it leads to large void artifacts in …
-
Electrochemical Deposition of Magnetics Based Sensors
… are seeing increased use. Electromagnetic catheter tracking is an application that depends on high-quality magnetic sensors. The size of the sensor is a significant design constraint in catheters. Investigation of a microfabricated inductive sensor is pursued in chapter 4 of this thesis. …
-
TOWARDS EFFECTIVE DISPLAYS FOR VIRTUAL AND AUGMENTED REALITY
… medical AR system that visualizes the occluded catheter in the external ventricular drainage (EVD) procedure. We develop an accurate and efficient catheter tracking method that requires minimal changes to the existing medical equipment. The AR display projects a virtual image of the catheter …
-
Photoacoustic Imaging For Image-Guided Interventions
… (EVLA), which utilizes an ultrasound (US)-guided catheter carrying high power continuous wave (CW) energy for treating varicose veins. Varicose veins, a condition defined by venous insufficiency, affects nearly 40 million people in the United States annually. In EVLA procedures, US limitations …
-
In Vivo Molecular Magnetic Resonance Imaging via Hyperpolarized Silicon Particles
… first explored their application for MRI-guided catheter tracking, demonstrating catheter tip tracking in 2D, 3D and in vivo over extended period of time without the use of ionizing radiation. Paving way for potential targeted molecular imaging applications, we characterized silicon particles of …
-
Motion gating for x-ray guided interventional electrophysiology procedures
… thereby allowing accurate determination<br/>of catheter-based ablation treatment sites. Motion gating is crucial for achieving this accuracy. Four novel and clinically applicable robust-to-noise motion gating techniques are developed and presented in this thesis.<br/>The first proposed …
-
Learning based Curvilinear Structure Analysis in Medical Images
… segmentation in retinal images, deformable tracking of curvilinear structures in X-ray sequences. Curvilinear structure analysis is often challenging due to large variations in their appearances and profiles, as well as image noise. Also, low visibility and poor image quality due to a low …
-
Novel Tools for Interventional Magnetic Resonance Imaging
… particularly abdominal needle and common catheter-based endovascular interventions. Firstly, a set of MRI-safe devices (guidewires, micro guidewires, catheters and micro catheters) were developed with passive or inductively coupling resonant markers for MRI visualisation. Secondly, a …