Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 92 for “"Cavity Ring-down Spectroscopy"”.

  1. Pulsed cavity ring-down spectroscopy in combustion environments

    This thesis gives an introduction to pulsed cavity ring-down absorption spectroscopy (CRDS) and its application in combustion research. Experimental results have been compared to numerical simulations, providing a means to validate reaction mechanisms and numerical approaches. Up to now, the …

    radboud Repository record for Pulsed cavity ring-down spectroscopy in combustion environments (opens in a new tab) Download PDF for Pulsed cavity ring-down spectroscopy in combustion environments (opens in a new tab)

  2. Probing Reactions in Monolayers Using Normal Incidence Cavity Ring-down Spectroscopy

    … dissociation of the polymer. Normal incidence cavity ring-down spectroscopy (NICRDS) was used to probe the monolayer system. Cavity ring-down spectroscopy (CRDS) is an ultra-sensitive absorption technique which has been extensively used for detection of gas-phase species and has recently been …

    unr Repository record for Probing Reactions in Monolayers Using Normal Incidence Cavity Ring-down Spectroscopy (opens in a new tab)

  3. Cavity ring-down spectroscopy instrumentation for airborne detection of nitrogen oxides

    Pulsed laser cavity ring-down spectroscopy (CaRDS) is a highly sensitive method for direct absorption spectroscopy that has been applied to in-situ detection of NO3, N2O5, NO2, NO, and O3, as well as NOx and NOy in the atmosphere from a variety of airborne platforms. CaRDS instruments have …

    cork Repository record for Cavity ring-down spectroscopy instrumentation for airborne detection of nitrogen oxides (opens in a new tab)

  4. Investigating reactive tropospheric nitrogen oxides by thermal-dissociation cavity ring-down spectroscopy

    … infrared (FTIR) and thermal dissociation cavity ring-down spectroscopy (TD CRDS). The interference from HONO in the measurement of NO2 by photolytic conversion with chemiluminescence detection (P-CL) was investigated in two prototype converters. The first used radiation centred around 395 …

    calgary Repository record for Investigating reactive tropospheric nitrogen oxides by thermal-dissociation cavity ring-down spectroscopy (opens in a new tab)

  5. Barium sensing in hollow cathode plasma using cavity ring-down spectroscopy (CRDS)

    … A BaO HC using the laser diagnostic technique of cavity ring-down spectroscopy (CRDS) is presented. CRDS detects ground state neutral barium via absorption of the probe laser beam in the vicinity of 553.548 nm (air wavelength). The cathode CRDS measurements are performed along the axis of the …

    colostate Repository record for Barium sensing in hollow cathode plasma using cavity ring-down spectroscopy (CRDS) (opens in a new tab)

  6. Indirect Detection of Explosive Vapours by Thermal Dissociation Cavity Ring-Down Spectroscopy

    … technique exploited radicals generated during the thermal decomposition of triacetone triperoxide (TATP), a peroxide explosive, for detection. These radicals were amplified via a peroxide radical chemical amplification scheme (PERCA) that required the addition of NO and a radical chain …

    calgary Repository record for Indirect Detection of Explosive Vapours by Thermal Dissociation Cavity Ring-Down Spectroscopy (opens in a new tab)

  7. Continuous-wave cavity ring down spectroscopy sensor for Hall thruster erosion measurement

    … its development in future applications requiring a long operational time (several thousands of hours). Sputter erosion of boron nitride (BN) acceleration channel wall is principal lifetime limitation for Hall thrusters. The sputtered particles can redeposit causing a critical contamination …

    colostate Repository record for Continuous-wave cavity ring down spectroscopy sensor for Hall thruster erosion measurement (opens in a new tab)

  8. Ambient Measurements of the NOx Reservoir Species N2O5 using Cavity Ring-down Spectroscopy

    … the SHARP Field Study in Houston, TX in the spring of 2009. N2O5 measurements are compared to measurements of other species, including nitric acid and nitryl chloride, which were performed by other research groups. Mixing ratios exceeding 300 ppt were observed following ozone exceedance days, …

    tamu Repository record for Ambient Measurements of the NOx Reservoir Species N2O5 using Cavity Ring-down Spectroscopy (opens in a new tab)

  9. A New Diffuse Reflecting Material with Applications Including Integrating Cavity Ring-Down Spectroscopy

    … new material to several areas of integrating cavity enhanced spectroscopy, including absorption, Raman, and fluorescence spectroscopy. In addition, we demonstrate a new spectroscopic technique based on cavity ring-down spectroscopy using an integrating cavity made of our new diffuse reflector. …

    tamu Repository record for A New Diffuse Reflecting Material with Applications Including Integrating Cavity Ring-Down Spectroscopy (opens in a new tab)

  10. Cavity ring down spectroscopy: a method to measure sputter erosion for EP applications

    … assessment. The present research develops cavity ring-down spectroscopy (CRDS) as a diagnostic tool to quantify sputter erosion. Measurements of sputtered particle number density and velocity are presented for a variety of target materials. The number density measurements are validated by …

    colostate Repository record for Cavity ring down spectroscopy: a method to measure sputter erosion for EP applications (opens in a new tab)

  11. Investigation of Aerosol Optical and Chemical Properties Using Humidity Controlled Cavity Ring-Down Spectroscopy

    … modeling. In this work a Humidity-Controlled Cavity Ring-Down (HC-CRD) aerosol optical instrument is described and its ability to measure RH dependent extinction coefficients and related hygroscopicity parameters is characterized. The HC-CRD is capable of simultaneously measuring the aerosol …

    portland-state Repository record for Investigation of Aerosol Optical and Chemical Properties Using Humidity Controlled Cavity Ring-Down Spectroscopy (opens in a new tab)

  12. Nighttime Measurements of Dinitrogen Pentoxide and the Nitrate Radical via Cavity Ring-Down Spectroscopy

    … in situ optical absorption technique, known as cavity ring-down spectroscopy, will be introduced for simultaneously measuring the nitrate radical and dinitrogen pentoxide. The cavity ring-down spectrometer was initially designed and constructed based on the experiments by Steven Brown and …

    tamu Repository record for Nighttime Measurements of Dinitrogen Pentoxide and the Nitrate Radical via Cavity Ring-Down Spectroscopy (opens in a new tab)

  13. Cavity Ring-Down Spectroscopy with DFB Diode Lasers near 1.6 Micron for Breath Analysis

    The near-infrared continuous-wave cavity ring-down spectroscopy (CW-CRDS) technique is applied to determine methane and acetone concentrations in human breath samples. The research quantifies methane and acetone concentrations, the biomarkers indicative of colon problems and diabetes, respectively. …

    tamu Repository record for Cavity Ring-Down Spectroscopy with DFB Diode Lasers near 1.6 Micron for Breath Analysis (opens in a new tab)

  14. Cavity ring-down spectroscopy measurements of NH₂ in a pulsed nanosecond ammonia plasma reactor

    … of NH2 measurements by the extremely sensitive cavity ring-down spectroscopy (CRDS) laser absorption diagnostic. The cylindrical shaped plasma reactor operates with high voltage pulses (~1.9 to 28 kV) of duration 15 ns delivered at frequencies of ~10-100 kHz. Fast high-voltage probes are used to …

    colostate Repository record for Cavity ring-down spectroscopy measurements of NH₂ in a pulsed nanosecond ammonia plasma reactor (opens in a new tab)

  15. Health Monitoring of Machinery Fluids Using Excitation-Emission Matrix Spectroscopy and Cavity Ring-Down Spectroscopy

    … machinery liquids plays a critical role in ensuring safe and cost-effective operation of engines. Especially in the aviation industry, there is a great need for real-time and online monitoring of the purity, lubricity and age of machinery fluids. In this work, two optical techniques, …

    queens Repository record for Health Monitoring of Machinery Fluids Using Excitation-Emission Matrix Spectroscopy and Cavity Ring-Down Spectroscopy (opens in a new tab)

  16. A cavity ring-down spectroscopy system for high time resolution measurements of gaseous elemental mercury concentrations

    … measurements of GEM in ambient air using pulsed cavity ring-down spectroscopy (CRDS). In this research, a CRDS system was developed using a pulsed laser (50 Hz pulse repetition rate) emitting wavelengths tunable between 215 and 280 nm (Hg absorbs at 253.65 nm), a high finesse 1-m-long cavity …

    unr Repository record for A cavity ring-down spectroscopy system for high time resolution measurements of gaseous elemental mercury concentrations (opens in a new tab)

  17. Development and applications of condensed phase cavity ring-down spectroscopy for studies of electrochemical and interfacial.

    … of ultra-sensitive platforms based on the laser cavity ring-down spectroscopic (CRDS) technique to enable optical and spectroelectrochemical investigations in the condensed phase of matter at challenging scenarios. Firstly, an electrically-active solid/liquid interface for the evanescent-wave …

    louisville Repository record for Development and applications of condensed phase cavity ring-down spectroscopy for studies of electrochemical and interfacial. (opens in a new tab)

Page 1 of 5