Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"Cavity-ringdown spectroscopy"”.

  1. Comparisons of cavity ringdown spectroscopy

    Includes bibliographical references (pages 105-106).

    colo-mines Repository record for Comparisons of cavity ringdown spectroscopy (opens in a new tab)

  2. Cavity ringdown spectroscopy for broadband and microfluidics applications

    Cavity Ringdown Spectroscopy (CRDS) is a highly sensitive, absorption spectroscopy technique. From the measurement of the decay of light within an optical cavity, spectroscopic parameters of an absorbing sample can be determined. Thus far the technique has mostly been applied to gas-phase samples. …

    oxford Repository record for Cavity ringdown spectroscopy for broadband and microfluidics applications (opens in a new tab)

  3. Frequency domain digital signal processing for cavity ringdown spectroscopy

    … the throughput, and thus the sensitivity, of Cavity Ringdown Spectroscopy (CRDS). Almost all of the experiments in the literature are designed to generate single decay transients, and achieve sensitivity improvements by increasing the reflectance of the cavity mirrors. We have designed and …

    unsw Repository record for Frequency domain digital signal processing for cavity ringdown spectroscopy (opens in a new tab)

  4. Cavity Ringdown Spectroscopy in Nitrogen/Oxygen Mixtures in the Presence of Alpha Radiation

    … for radiation-induced atmospheric effects. Cavity Ringdown Spectroscopy (CRDS) was used to measure the concentration of chemical products generated as a result of radiation interactions in a controlled atmosphere. Experiments were conducted in a vacuum chamber interfaced with a gas …

    usm Repository record for Cavity Ringdown Spectroscopy in Nitrogen/Oxygen Mixtures in the Presence of Alpha Radiation (opens in a new tab)

  5. UF-CRDS: a pulsed uniform supersonic flow apparatus coupled with continuous-wave cavity ringdown spectroscopy

    … in which highly sensitive continuous wave-cavity ringdown spectroscopy (cw-CRDS) is coupled with a pulsed uniform flow for the first time, a "uniform flow cavity ringdown spectrometer," UF-CRDS. The UF-CRDS setup is equipped with a pulsed uniform flow system which is produced by means of a …

    missouri Repository record for UF-CRDS: a pulsed uniform supersonic flow apparatus coupled with continuous-wave cavity ringdown spectroscopy (opens in a new tab)

  6. Mechanistic Insights from the 15N-Site Preference of Nitrous Oxide utilizing High Resolution Near-Infrared cw Cavity Ringdown Spectroscopy and Density Functional Theory Calculations

    … on a novel ultrasensitive, high resolution cw cavity ringdown spectrometer, an approach to determine this parameter spectroscopically has been followed. Furthermore, the detailed formation mechanism of N2O from HNO dimerization has been assessed theoretically based on DFT calculations. Finally, …

    cau-kiel Repository record for Mechanistic Insights from the 15N-Site Preference of Nitrous Oxide utilizing High Resolution Near-Infrared cw Cavity Ringdown Spectroscopy and Density Functional Theory Calculations (opens in a new tab)

  7. High-resolution spectroscopic studies of carbon-containing species

    … fundamental side, high-resolution rovibrational spectroscopy allows molecular constants to be determined and provides evidence of theoretical assumptions. Work to this end was performed using cavity-ringdown spectroscopy and either a gas phase or supercritical fluid supersonic expansion source. …

    uiuc Repository record for High-resolution spectroscopic studies of carbon-containing species (opens in a new tab)

  8. A System for Measuring Radiation Induced Chemical Products in Atmospheric Gases Using Optical Detection Methods

    … This project explored the potential for using Cavity Ringdown Spectroscopy to evaluate the presence of chemical products generated by the air-radiation interaction near an alpha radiation source. In particular, measurements of ozone concentration within a controlled atmosphere chamber as …

    usm Repository record for A System for Measuring Radiation Induced Chemical Products in Atmospheric Gases Using Optical Detection Methods (opens in a new tab)

  9. A CRYOGENIC OPTICAL CAVITY FOR DIRECT ABSORPTION EXPERIMENTS: HIGH RESOLUTION SPECTROSCOPY OF BUFFER-GAS-COOLED MOLECULES

    … instrument that combines buffer-gas cooling and cavity ringdown spectroscopy. The first portion of this dissertation (Chapter 2) details the construction and design of this instrument, as well as physics by which it operates. Chapter 3 discusses the use hydrogen cyanide as a initial probe …

    maryland Repository record for A CRYOGENIC OPTICAL CAVITY FOR DIRECT ABSORPTION EXPERIMENTS: HIGH RESOLUTION SPECTROSCOPY OF BUFFER-GAS-COOLED MOLECULES (opens in a new tab)

  10. Development of a Portable Cavity Ring-Down Spectroscopic Technique for Measuring Stable Isotopes in Atmospheric Methane

    … spectroscopic isotope ratio instrument using cavity ringdown spectroscopy in the near IR region using the ν2+2ν3 overtone band. This region has limited interference from other molecules, and an advantageous juxtaposition of a 13CH4 triplet, and a single 12CH4 peak, allowing near-simultaneous …

    portland-state Repository record for Development of a Portable Cavity Ring-Down Spectroscopic Technique for Measuring Stable Isotopes in Atmospheric Methane (opens in a new tab)

  11. A System For Conducting Laser-Induced Fluorescence Measurements On Gas Mixtures Exposed To Alpha Radiation

    … system to allow laser-induced fluorescence spectroscopy measurements within simulated atmospheres under a variety of conditions. This added capability will expand the laboratory’s ability to experimentally validate a computational model that calculates the effects of radiation within the …

    usm Repository record for A System For Conducting Laser-Induced Fluorescence Measurements On Gas Mixtures Exposed To Alpha Radiation (opens in a new tab)

  12. Investigation of Volatile Organic Compounds Emissions in Different Stages of HVAC System

    … of CO, CO2, CH4, NH3, and CH2O using cavity ringdown spectroscopy instrumentation from Picarro through a four-valve switching chamber. This process allowed us to sample multipoint pollutants in mixed air, post-filter air, supply air, and return air in a frequent switching sequence. Our …

    jhu Repository record for Investigation of Volatile Organic Compounds Emissions in Different Stages of HVAC System (opens in a new tab)

  13. Development, enhancement, and evaluation of aircraft measurement techniques for criteria pollutants

    … America's most recalcitrant pollutant. Using cavity ringdown spectroscopy employing a light emitting diode (LED), I measured vertical profiles of NO¬2 (surface to 2.5 km) west (upwind) of the Baltimore/Washington, area in the morning, and east (downwind) in the afternoon. Column contents …

    maryland Repository record for Development, enhancement, and evaluation of aircraft measurement techniques for criteria pollutants (opens in a new tab)

  14. Spectroscopic and theoretical investigation of selected cyclic and bicyclic molecules in their ground and excited electronic states

    … states were determined using ultraviolet cavity ringdown spectroscopy (CRDS). The CRDS data allowed several of the quantum states of the ring inversion vibration to be determined for both the ground and excited electronic states, and the data were fit very well with PESs with high barriers …

    tamu Repository record for Spectroscopic and theoretical investigation of selected cyclic and bicyclic molecules in their ground and excited electronic states (opens in a new tab)

  15. Modifications to a Cavity Ringdown Spectrometer to Improve Data Acquisition Rates

    Cavity ringdown spectroscopy (CRDS) makes use of light retention in an optical cavity to enhance the sensitivity to absorption or extinction of light from a sample inside the cavity. When light entering the cavity is stopped, the output is an exponential decay with a decay constant that can be used …

    portland-state Repository record for Modifications to a Cavity Ringdown Spectrometer to Improve Data Acquisition Rates (opens in a new tab)

Page 1 of 2