Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 93 for “"Cell Capture"”
-
Design Optimization Of Microfluidic Devices For Rare Cell Capture
The capture of rare cells from complex fluids, such as circulating tumor cells (CTCs) from a peripheral blood sample, has the potential to significantly advance our understanding and treatment of disease. Here, we consider microfluidic devices designed to isolate rare cells by bringing them into …
-
Engineering Cholesterol-Based Fibers for Antibody Immobilization and Cell Capture
… During cancer metastasis, circulating tumor cells (CTCs) are shed from primary tumors and migrate through bodily fluids, establishing secondary cancer sites. As cancer metastasis is incredibly lethal, there is a growing emphasis on developing "liquid biopsies" that can screen peripheral …
-
Small Footprint High Flow Rate Microdevice for Rare Target Cell Capture
A novel high flow rate cell capture design was introduced to overcome the limitations of the current technologies or methods for rare target cell capture. Even though the rare target cell capture using BioMEMS technology has great potential for cancer diagnosis, previous rare cell capture research …
-
CD133 Antibody Conjugation to Decellularized Human Heart Valves For Circulating Endothelial Progenitor Cell Capture
… and calcification. To avoid this degeneration, decellularized heart valves with functionalized surfaces capable of rapid in vivo endothelialization have been developed. The aim of this study is to examine the capacity of CD133 antibody-conjugated valve tissue to capture circulating endothelial …
-
The effect of phenotypic heterogeneity on pancreatic circulating tumor cell capture and tumor spheroids
… phenotypic heterogeneity in pancreatic cancer cells influences the performance of platforms engineered to analyze rare cells in patient blood samples, and the self-assembly of cancer cells into tumor spheroids. These endeavors were spurred on by our early observation that circulating epithelial …
-
A transparent platform for cell capture and single cell isolation of circulating tumour cells
… transparent and easily constructed platform for cell capture and single cell isolation of circulating tumour cell (CTC). CTCs have tremendous values in early cancer detection and understanding the mechanism of metastasis. There is a need in the field to develop an accessible and easily operated …
-
Design, Fabrication, and Implementation of a Single-Cell Capture Chamber for a Microfluidic Impedance Sensor
A microfluidic device was created for single-cell capture and analysis using polydimethylsiloxane (PDMS) channels and a glass substrate to develop a microfluidic single-cell impedance sensor for cell diagnostics. The device was fabricated using photolithography to create a master mold which in turn …
-
Development of a Multifunctionalized Vascular Scaffolding System to Induce In Situ Endothelial Cell Capture, Smooth Muscle Cell Migration, and Prevention of Inflammatory Cell Infiltration
Cardiovascular disease (CVD) is the leading cause of death globally, and is responsible for innumerable complications related to the peripheral vascular system. Peripheral vascular disease and vascular trauma are major contributors toward the need of feasible, effective surgical interventions for …
-
BIOSENSING TOTAL BACTERIAL LOAD IN LIQUID MATRICES TO IMPROVE FOOD SUPPLY CHAIN SAFETY USING CARBOHYDRATE-FUNCTIONALIZED MAGNETIC NANOPARTICLES FOR CELL CAPTURE AND GOLD NANOPARTICLES FOR SIGNALING
… by antibodies, although with lower specificity. Capture index (CI) is defined as the parts-per-thousand (ppt) of bacteria extracted per initial bacterial presence. TEM mages showed that attached milk matrix components did not interfere with microbial. capture. Salmonella, E. coli, and Bacillus (3 …
-
Magnetic Endothelialization of Flow Diverters to Promote Rapid Healing of Cerebral Aneurysms
… is to evaluate the efficacy of magnetic cell capture for the endothelialization of flow diverters to more rapidly endothelialize the luminal surface of the devices. To evaluate this 2205 duplex stainless steel flow diverters and cobalt chromium flow diverters underwent magnetic …
-
Cell attachment to Zein surfaces
… as tissue engineering and circulating cancer cell retrieval. Understanding the mechanism of cell-substrate interaction is pivotal for exploiting the potential of those materials. Adhesion of cells to substrate surfaces is often mediated by tissue transglutaminase (tTG) in its role as a …
-
Single Cell Impedance Measurements Using Microfabricated Electrodes and Labview Graphical Programming
… impedance measurements (1kHz-20Mhz) of single cells using National Instruments Labview data acquisition and programming in coordination with a single cell capture device. Presented first is the background information on cells and their electrical properties, along with background in …
-
Characterization Of Microfluidic Shear-Dependent Immunocapture And Enrichment Of Cancer Cells From Blood Cells With Dielectrophoresis
… of dielectrophoresis (DEP) on microfluidic immunocapture of prostate cancer and pancreatic cancer cells. We make novel measurements of these cancer cells' DEP response, and characterize the combination of DEP and immunocapture techniques as a function of shear stress in a Hele-Shaw flow cell with …
-
Towards Rapid Label-free Enrichment of Specific Stem Cell Populations for Autologous Cell Therapies
Autologous mesenchymal stem cell (MSC) therapies have huge potential in addressing clinical challenges for otherwise intractable diseases. Label-free, intra-operative separation and enrichment of MSC subpopulations would provide a step change in delivery of such therapies. The long term goal of …
-
Microsystem Technology for Next-generation Cellular Therapy
Cellular therapy is a treatment where viable cells are injected or grafted into a patient in order to generate therapeutic effects, such as grafting stem cells to regenerate damaged tissues or injecting autologous T cells to fight cancer. The advancement of cellular therapy in clinical trials has …
-
Studies of Microfluidic Affinity Cell Separation for Bioanalysis and Clinical Application
… fundamentals of microfluidics, microfluidic cell separation techniques, and biomarker detections on microfluidics. In Chapter II, III, and IV, three studies of antigen measurement via microfluidic affinity cell separation technique are presented in details. Chapter V is the conclusion and …
-
Automated Analysis of Flow Cytometry Data for B-Cell Lymphoma
… of hematolymphoid malignancies including B-cell lymphomas, is an innovative technique that measures the fluorescence of suspended cells. Traditionally, the method of evaluating the research and clinical study of flow cytometry data is done by the process of manual gating along with a review …
-
Studies of microfluidic devices for cell separation and analysis
… research. This dissertation focuses on affinity cell separation and cell culture in microfluidic devices. Three detailed studies are presented. First, surface ligand patterning is of vital importance for affinity separations. The ability to coat different ligands in separation devices can …
-
Differentiation of Bone Marrow Derived Mesenchymal Stem Cells (BM-MSCs) Using Engineered Nanofiber Substrates
… scaffolds (NFS) mimicking natural extracellular matrix (ECM) provided efficient cell attachment and enhanced osteogenic differentiation to promote bone regeneration. Structurally, bone encompasses fiber bundles that are made up of collagenous nanofibrils laced with HA nanocrystals. …
-
Cellular Microarrays for Interrogation of Cell-Cell and Cell-Substrate Interactions
<p>The interaction of cell surface receptors with their counterparts on the other cell or on an extracellular substrate, and subsequent signal transduction triggered/induced by these interactions, crucially dictate the survival, development, and function of the cell. In recent years, cellular …