Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 47 for “"Certified reference materials"”.
-
Development of reference methods and reference materials for trace level antibiotic residues in food using IDMS
… traceability of measurement results, reference methods and certified reference materials (CRMs) are needed. Nitrofuran antibiotic drugs used for the treatment of bacterial and protozoan infections in animals were studied in this thesis. A high accuracy reference method and an …
-
Ανάπτυξη αυτόματων αναλυτικών μεθόδων ατομικής φασματομετρίας με συνδυασμό μικροτεχνικών ροής και εκχύλισης στερεάς φάσης για τον προσδιορισμό μετάλλων
… the proposed method was evaluated by analyzing certified reference materials and biological samples. 2) A novel simple and sensitive on-line flow injection fabric fiber sorbent extraction system adapted to flame atomic absorption spectrometry for automatic metal determination has been …
-
Determination of silver using cyclic epithermal neutron activation analysis
… analysis (CENAA). Various NIST and CANMET certified materials were analyzed by the system. Experiment results showed 110Ag as one of the isotopes favored by the system. Thus, the system was put into practical application for identifying silver concentration in the Arctic atmospheres in air …
-
Improved Sample Introduction Systems for Inductively Coupled Plasma Optical Emission Spectrometry and Their Application to the Analysis of Simple and Complex Matrices
… precision, and robustness, and analyzing two certified reference materials, a method with improved sample introduction efficiency and comparable analytical performance to a previous method was established. 2. The second project involved improvements to a previous work in which a multimode …
-
Determination of total selenium and seleno-amino acids in yeast and aquatic organisms by liquid chromatography and inductively coupled plasma mass spectrometry
… determination of total selenium in biological materials, such as selenized yeasts, certified reference materials, lab-cultured oligochaetes and desert pupfish. The separation and quantitation of seleno-amino acids was accomplished by ion-pairing reversed-phase liquid chromatography (RPLC) and …
-
The Development Of On-line Microwave Digestion Techniques For Environmental Matrices
… validated by the analysis of suitable certified reference materials. These techniques demonstrated a number of advantages over conventional methods including less reagent usage, less contamination and substantial time savings. Speciation studies have been a focus for this work and have …
-
CHARACTERIZATION OF AN ARGON-HYDROGEN PLASMA TORCH FOR PRODUCTION OF SURROGATE NUCLEAR MELT GLASS
… nuclear melt glass which can be used to create certified reference materials, improve forensics methods, and train emergency response teams. Several methods for producing surrogate melt glass currently exist and each has its advantages and disadvantages. Most of the production methods currently …
-
Development of numerical simulation methods to support emerging rapid and automated radioanalytical techniques
… work and is often hindered by a lack of certified reference materials and isotopic tracers. The development of software to simulate chromatographic breakthrough and elution profiles would therefore be a useful tool in method development and validation as well as in support of routine …
-
Microwave-assisted sequential extraction of polyclic aromatic hydrocarbons and potentially toxic elements from urban environmental solids
… of PTEs. The method was developed using certified reference materials (CRMs) and several urban substrates. The determination of PTE by the developed sequential method was compared to a single step aqua regia digestion, with recoveries of 80.9-107% (without PAH extraction) and 82.3-97.1% …
-
Determination of trace elements in crude oils by ICP-MS using detergent microemulsion.
… was confirmed by analysing two different certified reference materials (Used Oil HU-1 from SCP science and Wear Metals in Lubricating Oils 1084a from NIST). The recoveries ranged from 100.1% to 119.9 % for all elements and 85.1 % for Cr in Used Oil HU-1 and from 84.8 % to 100.1 % for all …
-
Determination of Zinc Isotopic Composition in Biological Tissues
… yield recovery rate (95%) during processing. Certified Reference Materials (CRMs) such as Bovine Liver (NIST1577c); Human Hair (GBW07601, USGS42, USGS43); Whole Blood (SeroNorm); Bone Ash (NIST1400); and Bone Meal (NIST1486) were used to validate the accuracy and precision of the method. To …
-
Desenvolvimento de método para determinação de cloro em petróleo via molécula MgCl por HR-CS MAS
… oil samples from the Potiguar Basin and two certified reference materials, lubricated oil (NIST 1848) and fuel oil (NIST 1634c) were used, to verify the accuracy of the method. The calibration strategy against aqueous standards was possible, obtaining the LOD of 5 mg kg-1. Addition / recovery …
-
Transgeninių elementų paieškos sistemos parinkimas ir metodo optimizavimas naujų GM sojos linijų kontrolei /
… for new GM soy events using DNA extracted from certified reference materials. Parameters of standard DNA calibration curves meet the requirements and fall into required range. This confirms the suitability of standart curves to use in further method development. The standard calibration curves …
-
Study of Charged Aerosol Detection for Purity Assessment of Organic Compounds
… sports doping control community. Using certified reference materials of testosterone, testosterone glucuronic acid, related steroid glucuronic acids, and testosterone sulfate, the CAD sensitivity was shown to be superior to evaporative light scattering detection (ELSD), providing a …
-
Optimizing a Method for the Direct Determination of Rare Earth Elements in Refractory Geological Materials Using Electrothermal Vaporization Coupled to Inductively Coupled Plasma Optical Emission Spectrometry
… preparing aqueous solutions from refractory materials is difficult, time-consuming, and costly. For this reason, a direct solid sample analysis method would be preferred. Electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry (ETV-ICPOES) enables the …
-
Human Dietary Exposure to Arsenicals in Seafood: Occurrence and Analytical Considerations
… and lack of commercially available standards and certified reference materials. Identification and quantification of the toxic arsenic species is imperative to understanding the risk associated with exposure to arsenic from dietary intake, which in turn underscores the need for speciation …
-
Interfacing the Liquid Sampling- Atmospheric Pressure Glow Discharge Ion Source with Orbitrap Mass Spectrometers for High Accuracy High Precision Isotope Ratio Measurements of Uranium
… Uncertainties in Safeguarding Nuclear Materials for U samples. The LS-APGD offers a number of attractive operating parameters for a field deployable source, including gas flow rates of 200 – 1000 mL min-1, liquid flow rates of 5-60 μL min-1 and power consumption of <50 W, all while …
-
Anthropogenic impacts on urban watersheds : insights from LA-ICP-MS analyses of bald cypress tree cores
… by solution ICP-MS measurements of two certified reference materials. The time series of elemental concentrations revealed (1) distinctly different patterns between sapwood and heartwood, (2) distinct increases in concentrations coinciding with severe drought, (3) similarities between …
-
Kashin-Beck Disease: evaluation of mineral intake in young Tibetan children from endemic areas
… The analytical method was validated by mean of certified reference materials. Mean food contents were calculated and compared to food composition reference tables. High iron contents and selenium deficiencies were highlighted in several foods. Daily intakes were estimated combining mineral …
-
Slurry, Solution and Speciation Analysis By Inductively Coupled Plasma Atomic Emission Spectrometry
… and optimisation algorithms. A range of certified reference materials have been analysed using optimum conditions and results were in good agreement with certified values. Slurry nebulisation has been used for the first time in the analysis of NIST SRM Total Diet' and carbon black …
Page 1 of 3