Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 16 of 16 for “"Cesium ions."”

  1. Recrystallization Kinetics of 3C Silicon Carbide Implanted with 400 keV Cesium Ions

    … was implanted at room temperature with 400 keV cesium ions to a dose of 1016 ions·cm-2. The samples were then annealed at 600 – 1000°C for 0-48 hours in ultra-high purity argon. The implanted zone of each sample was characterized by transmission electron microscopy and secondary ion mass …

    boise Repository record for Recrystallization Kinetics of 3C Silicon Carbide Implanted with 400 keV Cesium Ions (opens in a new tab)

  2. The angular distribution of single crystal molybdenum sputtered by 1-10 keV cesium ions.

    … of sputtered molybdenum by a 1-10 kev cesium ion beam parallel to the <100> crystallographic direction have successfully been made employing a radioactive tracer technique previously developed for similar work done with copper. The yield was found to be dependent not only upon the …

    nps Repository record for The angular distribution of single crystal molybdenum sputtered by 1-10 keV cesium ions. (opens in a new tab)

  3. Chemical Extraction of Non-exchangeable Radiocesium from Fukushima Soils using Ion-exchange and Selective Precipitation

    … by Tamura et al. employed the use of various ions to exchange cesium ions and reported that among all ions explored magnesium ions were more likely to replace cesium ions. However, after about two hours due to the high affinity of cesium ions for the clay minerals, cesium replaced magnesium. …

    kennesaw Repository record for Chemical Extraction of Non-exchangeable Radiocesium from Fukushima Soils using Ion-exchange and Selective Precipitation (opens in a new tab)

  4. Studies of Diet as a Factor in 137-Cesium Metabolism in Rats

    … to diet variation. The primary effect of diet on cesium metabolism was a modification of cesium excretion via urine and feces. There appeared to be a direct relationship between mass of fecal material and the amount of 137Cs excreted in feces. Diet variation changed the composition and amount of …

    unm Repository record for Studies of Diet as a Factor in 137-Cesium Metabolism in Rats (opens in a new tab)

  5. A Novel Method of Studying Ion Formation and Fragmentation Using a Modified Time-of-Flight Mass Spectrometer

    … that an order of magnitude more neutrals than ions are produced during laser desorption. A Time-Of-Flight Mass Spectrometer with an infinitely adjustable acceleration region was constructed to map the population distribution of neutral ion precursors and metastable ions in the flight tube. …

    northern-iowa Repository record for A Novel Method of Studying Ion Formation and Fragmentation Using a Modified Time-of-Flight Mass Spectrometer (opens in a new tab)

  6. The unique pore and selectivity filter of HCN channels

    … classes of channels also allow mainly potassium ions to flow, are blocked by cesium ions, and are activated by extracellular potassium. However, HCN channels open when hyperpolarized, whereas most potassium channels open when depolarized. Thus, electromechanical coupling between the voltage …

    ubc Repository record for The unique pore and selectivity filter of HCN channels (opens in a new tab)

  7. Exploratory Synthesis of Plyanion-Based Open-Framework Solids As Potential Candidates For Cathode Material Applications

    … as cathode materials for primary battery applications; the former contains a higher (Ag+Mn)/V ratio, which is sought for high capacity devices, while the latter may prove better for lower power devices. The structures of the two materials differ in that Ag3Mn(VO4)2 is a layered material where as …

    clemson Repository record for Exploratory Synthesis of Plyanion-Based Open-Framework Solids As Potential Candidates For Cathode Material Applications (opens in a new tab)

  8. The investigation of the self-assemblies of pyrogallol [4] arenes with large metal ions

    … involves the study of the non-covalent interactions between molecules. Host molecules such as C-pyrogallol[4]arenes form complexes via these supramolecular interactions. Pyrogallol[4]arenes are known to interact with metal ions forming layered structures or metal-organic nanocapsules. Although …

    missouri Repository record for The investigation of the self-assemblies of pyrogallol [4] arenes with large metal ions (opens in a new tab)

  9. A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN

    … first time. Using matrix methods the motion of ions in a square-wave-driven trap were studied and the acceptance and the space charge limit of the trap calculated as a function of the operating parameter, q. A simple viscous drag model for the cooling process was then used to prove the cooling …

    ubc Repository record for A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN (opens in a new tab)

  10. Synthesis and Binding Properties of an Inherently Chiral calix[6]arene

    … conformation and provided the relevant dimensions of compound. When the racemic mixture was treated with 2 and 5 equivalents of Pirkle’s chiral reagent, two diastereomeric complexes were formed as evidenced by shifts in certain 'H NMR resonances for the host. Unfortunately attempts to …

    texas-state Repository record for Synthesis and Binding Properties of an Inherently Chiral calix[6]arene (opens in a new tab)

  11. Developing Computational Tools for the Study and Design of Amyloid Materials

    … and the ability to be redesigned through mutations at sequence level, which can result in potential functionality. Previous studies have reported the rational based design of functional amyloid materials, designed through primarily scientists’ intuition, and their applications in several fields …

    tamu Repository record for Developing Computational Tools for the Study and Design of Amyloid Materials (opens in a new tab)

  12. The Development of an Integrated Microengineered Ion Sensor (Inion) for Cesium

    … Microsensor (ISCOM) for the detection of cesium ions was devleoped. The operating principle of an ISCOM is based on the concentration dependant change in the bulk conductivity of an ion selective membrane. Changes in conductivity are achieved by salt extraction of the target ion into the …

    cent-lancashire Repository record for The Development of an Integrated Microengineered Ion Sensor (Inion) for Cesium (opens in a new tab)

  13. Enhancing natural clinoptilolite for cesium and strontium removal, using activation, flotation and process intensification

    … to treat liquid radioactive wastes (LRW) such as cesium and strontium. It is also radiation tolerant, as its structure does not degrade or alter due to cesium and strontium radiation. However, only high grade clinoptilolite can be used in the nuclear industry, which will place significant …

    whiterose Repository record for Enhancing natural clinoptilolite for cesium and strontium removal, using activation, flotation and process intensification (opens in a new tab)