Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"Cf-252"”.

  1. Shape and Structure of Neutron-Rich from Cf-252 Fission Fragments

    … nuclei were populated as fission fragments from 252Cf fission. The detector setup consisted of the Gammasphere spectrometer and the Hercules fast-plastic array. This allowed the measurement of asymmetric DSAM lineshapes at different Gammasphere detector angles with respect to the fission axis. …

    wustl Repository record for Shape and Structure of Neutron-Rich from Cf-252 Fission Fragments (opens in a new tab)

  2. Gamma and neutron dose profiles near a Cf-252 brachytherapy source

    A new generation of medical grade Cf-252 sources was developed in 2002 at the Oak Ridge National Laboratory (ORNL). The combination of small size and large activity of these Cf-252 sources makes them suitable to be used with the conventional high-dose-rate (HDR) remote afterloading systems for …

    gatech Repository record for Gamma and neutron dose profiles near a Cf-252 brachytherapy source (opens in a new tab)

  3. Study of the spontaneous fission of CF-252 with a time projection chamber

    Includes bibliographical references (pages 103-108).

    colo-mines Repository record for Study of the spontaneous fission of CF-252 with a time projection chamber (opens in a new tab)

  4. In-water neutron and gamma dose determination for a new Cf-252 brachytherapy source

    … encapsulated a new generation of medical grade Cf-252 sources having intensities and size comparable to that of the widely used high-dose-rate (HDR) Ir-192 brachytherapy sources. Advent of the new sources, therefore, marked a new era for Cf-252-based neutron brachytherapy (NBT). As part of …

    gatech Repository record for In-water neutron and gamma dose determination for a new Cf-252 brachytherapy source (opens in a new tab)

  5. Characterizing Photon and Neutron Responses in CDMS Detectors Using Real and Simulated Cf-252 Data

    … the next experiment. We focus on the Californium-252 calibration source used in the real experiment, as the neutrons it releases will produce signals similar to those caused by WIMPs; by comparing real Cf-252 data and data produced in our simulation framework, we can trace the physical processes …

    tamu Repository record for Characterizing Photon and Neutron Responses in CDMS Detectors Using Real and Simulated Cf-252 Data (opens in a new tab)

  6. Study of spontaneous (Cf-252) and neutron-induced (U-235,8) non-binary fission using the fission time projection chamber

    … study, measurements of non-binary fission of 252Cf (sf) and 235,8U (n,f) were performed using the fission time projection chamber (fissionTPC). The neutron source was provided by the Los Alamos Neutron Science Center with a neutron energy spectrum ranging from ∼ 100 keV to ∼ 300 MeV. The study …

    colo-mines Repository record for Study of spontaneous (Cf-252) and neutron-induced (U-235,8) non-binary fission using the fission time projection chamber (opens in a new tab)

  7. Time-of-flight spectrometry of the spontaneous fission neutron emission of Cm-244 and Cf-252 using EJ-309 liquid scintillators

    … to measure the prompt neutron energy spectrum of 252Cf and 244Cm, the latter of which has never been explored in this way. The Maxwellian fission spectrum has been fitted to the PFNS of 244Cm with a parameter T= 1.33 MeV (±0.7) and the Watt spectrum has been fitted with parameters of a =0.918 and …

    lancaster Download PDF for Time-of-flight spectrometry of the spontaneous fission neutron emission of Cm-244 and Cf-252 using EJ-309 liquid scintillators (opens in a new tab)

  8. Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry

    … for two different neutron sources (a Cf-252 source and a AmBe source) was measured using the new TEPC. The measurements were performed using two different proportional gases: P-10 gas and a propane-based tissue equivalent gas at various pressures. A computer simulation of the new TEPC, …

    gatech Repository record for Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry (opens in a new tab)

  9. Quantification of Fast-Neutron Sources with Coded Aperture Imaging

    … technique is discussed, and measurements of Cf-252 sources, acting as a surrogate Pu material, are reconstructed and analyzed. Using the methods developed here, a single 74 µCi Cf-252 point source placed at a distance of 200 cm is reconstructed within 2% of the known position and within 3% of …

    utk-theses Repository record for Quantification of Fast-Neutron Sources with Coded Aperture Imaging (opens in a new tab)

  10. Development and testing of an organic scintillator detector for fast neutron spectrometry

    … will be performed with the system, unmoderated Cf-252 and heavy-water moderated Cf-252. After the detection system has been verified, measurements will be made with an AmBe neutron source.

    gatech Repository record for Development and testing of an organic scintillator detector for fast neutron spectrometry (opens in a new tab)

  11. SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS

    … and Ir-192 under 50 Ci and a neutron source of Cf-252 with an activity of 100 Ci were considered as typical sources used in fixed industrial radiography. The PHITS Monte Carlo code was used to compute the appropriate concrete wall necessary to shield gamma radiation and the most effective …

    liege Repository record for SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS (opens in a new tab) Download PDF for SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS (opens in a new tab)

  12. Design, construction, and assessment of a neutron shield for CDMS test facilities.

    … Data was taken with the detector exposed to a Cf- 252 (neutron) source with and without the shield in order to determine the shielding capability of the polyethylene. The data was analyzed and the results demonstrated a consistent shielding effect on events appearing as nuclear recoils, …

    umn Repository record for Design, construction, and assessment of a neutron shield for CDMS test facilities. (opens in a new tab)

  13. Directional neutron surveys on a semiautonomous mobile robot for a radiological vault

    … performance of the aperture was evaluated with a Cf-252 neutron source. The shielding resulted in a maximum 21.75% difference in radiation coming directly through the aperture versus from a different direction. A Pioneer LX robot was successfully approved for operation in the main plutonium …

    texas Repository record for Directional neutron surveys on a semiautonomous mobile robot for a radiological vault (opens in a new tab)

  14. Electron Recoils In the PICO Direct Dark Matter Detection Experiment

    … of 2.95 keV. At this threshold, a 141 Bq Cf-252 neutron source and a 33 MBq Co-60 gamma source can be used to calibrate the nuclear and electron recoil response of PICO-40L. Existing sources have sufficient strengths to calibrate PICO-500 to the statistical accuracy required, provided that …

    queens Repository record for Electron Recoils In the PICO Direct Dark Matter Detection Experiment (opens in a new tab)

  15. Neutron protection factor determination and validation for a vehicle surrogate using a Californium fission source

    … Lawrence Livermore National Laboratory's (LLNL) Cf-252 Radiation Calibration Laboratory (RCL). The NPF, a component of the total radiation protection factor (RPF), is used to evaluate the inherent shielding and radiation protection of military personnel from a polyenergetic neutron source. When …

    nps Repository record for Neutron protection factor determination and validation for a vehicle surrogate using a Californium fission source (opens in a new tab)

  16. The design and testing of a novel compact real-time hybrid Compton and neutron scattering instrument.

    … using Cs-137 gamma sources of ~300 kBq and a Cf-252 neutron source featuring an emission rate of 106 neutrons per second. The developed instrument offers a real-time response with a scan time of 60 seconds and a further data analysis time of 60 seconds. The intrinsic efficiency of the …

    lancaster Download PDF for The design and testing of a novel compact real-time hybrid Compton and neutron scattering instrument. (opens in a new tab)

  17. Machine Learning and Neutron Sensing in Mobile Nuclear Threat Detection

    … system. For a 280,000 neutrons per second Cf-252 source placed 15.9 meters away, a 4σ [sigma] detection rate of 99.3% was expected at 5 m/s. These results support the conclusion that neutron sensing enhances the detection capabilities of systems like the DDLI when compared to gamma-only …

    utk-theses Repository record for Machine Learning and Neutron Sensing in Mobile Nuclear Threat Detection (opens in a new tab)

  18. The neutron fission cross section of 92U235 and 92U238 in the energy range 0.3-12.5 MeV

    … Xenon as the gas in question, and by using a Cf-252 natural fission source for testing during the development. The monitor detectors, chosen for the experiments, were standard neutron detectors. During a series of accelerator tests the optimum electronic data collection system was developed by …

    glasgow Download PDF for The neutron fission cross section of 92U235 and 92U238 in the energy range 0.3-12.5 MeV (opens in a new tab)

  19. Boron Nitride Neutron Detector with the Ability to Detect Both Thermal and Fast Neutrons

    … free paths of fast neutrons in BN, using a bare Cf-252 and AmBe source emitting fast neutrons ranging from 1 – 9 MeV, were determined to be approximately 7.6 cm and 5.2 cm, respectively. Furthermore, the study revealed the presence of turbostratic phase domains in BN (t-10BN), which exhibited a …

    ttu Repository record for Boron Nitride Neutron Detector with the Ability to Detect Both Thermal and Fast Neutrons (opens in a new tab)

Page 1 of 2