Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 56 for “"Chairside"”

  1. Einfluss der Chairside-Reinigung auf die Kontaminationsrückstände von Endodontiefeilen

    … sogenannter Interim-Stand der Zwischenablage und Chairside-Reinigung der Instrumente. In der vorliegenden Arbeit wurde daher untersucht, ob 1\. die Verwendung eines Interim-Standes als Chairside-Reinigung eine sinnvolle Vorreinigung für Wurzelkanalinstrumente darstellt, 2\. die Befüllung des …

    fu-berlin Repository record for Einfluss der Chairside-Reinigung auf die Kontaminationsrückstände von Endodontiefeilen (opens in a new tab)

  2. Methodenentwicklung zur Chairside-Reinigung von Wurzelkanalinstrumenten in unterschiedlich befüllten Interim-Ständen

    Die Dekontamination von beschmutzten endodontologischen Instrumenten ist aufgrund ihrer komplexen Feilengeometrie sehr schwierig, und zahlreiche Studien belegen, dass wiederaufbereitete Wurzelkanalinstrumente nicht immer frei von Verunreinigungen sind. Das Ziel dieser Untersuchung war es, eine …

    fu-berlin Repository record for Methodenentwicklung zur Chairside-Reinigung von Wurzelkanalinstrumenten in unterschiedlich befüllten Interim-Ständen (opens in a new tab)

  3. Practicability of a chairside approach for characterizing CAD/CAM resin-based composites

    … Kompositen verbessert. Darüber hinaus können sie chairside mit lichthärtenden Malfarben individualisiert werden. Im Rahmen unserer Studie sollte die Praxistauglichkeit der chairside-Individualisierung von Kronen aus CAD/CAM-Komposit dargestellt werden. Hierzu haben 13 unerfahrene Probanden …

    qucosa-diss Repository record for Practicability of a chairside approach for characterizing CAD/CAM resin-based composites (opens in a new tab)

  4. Fatigue failure load of lithium disilicate restorations cemented on a chairside titanium-base

    … disilicate restoration designs cemented on a chairside titanium-base (VariobaseTM for CEREC®, Straumann® LLC, USA) for restoring anterior implant restoration. MATERIALS AND METHODS: Left maxillary incisor restoration was virtually designed in 3 groups (n=10; CTD: lithium disilicate crowns …

    iupui Repository record for Fatigue failure load of lithium disilicate restorations cemented on a chairside titanium-base (opens in a new tab)

  5. Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient preference

    … in plaster and then scanned. The development of chairside oral scanners now allows direct intraoral scanning of the dentition, but questions remain regarding the accuracy of full-arch digital models acquired using this technology, the time required for such scanning, and patient acceptance. These …

    umn Repository record for Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient preference (opens in a new tab)

  6. Clinical Evaluation of Chairside-Fabricated Partial Crowns Made of Zirconia- Reinforced Lithium Silicate Ceramic - 2-Year-Results

    … für materialbezogenes Versagen von chairside-hergestellten Teilkronen (Cerec System SW 4.2, Sirona Dental Systems GmbH, Bensheim, Deutschland) unter Verwendung einer ZLS-Keramik (VITA Suprinity, VITA Zahnfabrik, H. Rauter GmbH & Co. KG, Bad Säckingen, Deutschland). Hierbei sollten …

    qucosa-diss Repository record for Clinical Evaluation of Chairside-Fabricated Partial Crowns Made of Zirconia- Reinforced Lithium Silicate Ceramic - 2-Year-Results (opens in a new tab)

  7. The effect of two buffer solutions on wear resistance and mechanical properties of chairside lithium silicate glass-ceramic materials

    Objective: To compare the impact of neutral and acidic environments on wear of lithium silicate glass-ceramics (LSGC) with and without crystallization firing after manufacturing.<br>Materials and Methods: Eight square-shaped specimens (7 × 7 × 2 mm) were manufactured from four commercially …

    freiburg-diss Repository record for The effect of two buffer solutions on wear resistance and mechanical properties of chairside lithium silicate glass-ceramic materials (opens in a new tab)

  8. Überlebensanalyse und klinische Nachuntersuchung einer maschinenbearbeitbaren Lithiumdisilikatkeramik (IPS e.max CAD LT) von Einzelzahnrestaurationen im Seitenzahngebiet im chairside-Verfahren: 10-Jahres-Ergebnisse

    … Restaurationen aus diesem Material im chairside-Verfahren mit Hilfe von CAD/CAM-Technik herzustellen, gewährt der modernen Zahnmedizin ökonomische Vorteile, wie beispielsweise die Präparationsanalyse in Echtzeit, selektive Wiederholbarkeit des Abdruckes, digitales Archivieren, …

    qucosa-diss Repository record for Überlebensanalyse und klinische Nachuntersuchung einer maschinenbearbeitbaren Lithiumdisilikatkeramik (IPS e.max CAD LT) von Einzelzahnrestaurationen im Seitenzahngebiet im chairside-Verfahren: 10-Jahres-Ergebnisse (opens in a new tab)

  9. Analysis of Flexural Strength and Monotonic Load to Failure Following Simulated Chairside Adjustments and Repair in a Lithium Disilicate Glass-Ceramic

    Introduction: There are no studies regarding e.max Press that evaluate post-adjustment healing protocols and their effect on the load to failure in a clinically relevant test. It is essential to find the ultimate treatment protocol which will help clinicians preserve the physical properties of the …

    marquette Repository record for Analysis of Flexural Strength and Monotonic Load to Failure Following Simulated Chairside Adjustments and Repair in a Lithium Disilicate Glass-Ceramic (opens in a new tab)

  10. FROM BENCH TO CHAIRSIDE: EVALUATION OF BIOLOGICAL EFFECTS OF PLATELET CONCENTRATES THROUGH AN IN-VITRO STUDY AND A RANDOMIZED CLINICAL TRIAL

    Autologous platelet concentrates are widely used in a variety of medical application with the aim of enhancing the regeneration of hard and soft tissue. The rationale of this clinical use lies in their enriched content of growth factors and other key molecules involved in promoting tissue healing. …

    milano Repository record for FROM BENCH TO CHAIRSIDE: EVALUATION OF BIOLOGICAL EFFECTS OF PLATELET CONCENTRATES THROUGH AN IN-VITRO STUDY AND A RANDOMIZED CLINICAL TRIAL (opens in a new tab)

  11. Time efficiency of digitally and conventionally produced single-unit restorations

    … was to compare the time efficiency of digital chairside and labside workflows with a conventional workflow for single-unit restorations. The time efficiency in this specific sense was defined as the time, which has to be spent in a dental office by a dental professional performing the relevant …

    zurich Repository record for Time efficiency of digitally and conventionally produced single-unit restorations (opens in a new tab)

  12. Influência dos diferentes fluxos de trabalho CAD/CAM na precisão e qualidade dos contatos proximais e oclusais em coroas de dissilicato de lítio

    … workflow using different CAD / CAM systems (Chairside and InLab) in lithium disilicate crowns, regarding the reproducibility and the quality of occlusal and proximal contacts. Lithium disilicate crowns were produced (n=50) and divided into the following groups: -Three chairside CAD / CAM …

    brazil-ufrn Repository record for Influência dos diferentes fluxos de trabalho CAD/CAM na precisão e qualidade dos contatos proximais e oclusais em coroas de dissilicato de lítio (opens in a new tab)

  13. The Effect of Surface Treatment on The Adhesive Strength of Chairside Hard Liners to Dental Polymers Used for The Conventional, Additive, and Subtractive Fabrication of Complete Dentures.

    … difference in the tensile bond strength of chairside denture liners to denture bases fabricated using additive, subtractive, and conventional methods (P>0.05). The highest bond strength was achieved with the combination of MucoHard denture liner and primed 3D printed denture bases. MucoHard …

    ohiolink Repository record for The Effect of Surface Treatment on The Adhesive Strength of Chairside Hard Liners to Dental Polymers Used for The Conventional, Additive, and Subtractive Fabrication of Complete Dentures. (opens in a new tab)

  14. Comparison of Tensile Bond Strength of Denture Reline Materials on Denture Bases Fabricated with CAD-CAM Technology

    … type, the lowest values were seen with the soft chairside relining materials and highest values with the hard lab reline material. As for the modes of failure, adhesive failures were observed predominantly with the printed denture base materials relined with soft chairside relining materials, …

    tamu Repository record for Comparison of Tensile Bond Strength of Denture Reline Materials on Denture Bases Fabricated with CAD-CAM Technology (opens in a new tab)

  15. Association of chair side salivary aMMP-8 findings with periodontal risk-assessment parameters in patients under supportive periodontal therapy

    … in Patienten der UPT oder aber, das aMMP-8 Chairside POC Tests vor allen anderen klinischen Parametern eine instabile Parodontitis detektieren können. Der diagnostische Mehrwert eines aMMP-8 Chairside POC Tests ist anhand der des Ergebnisses der Studie zu hinterfragen und bedarf …

    qucosa-diss Repository record for Association of chair side salivary aMMP-8 findings with periodontal risk-assessment parameters in patients under supportive periodontal therapy (opens in a new tab)

  16. COMPARISON OF MANUFACTURED AND HAND-FORMED REVERSE CURVE OF SPEE NICKEL-TITANIUM WIRES

    … shape a flat superelastic NiTi archwire chairside into a reverse curve of Spee. This study compared the mechanical and thermal properties of manufactured RCOS, hand-formed RCOS (hf-RCOS), and flat superelastic NiTi archwires to determine whether hand-formed archwires are clinically …

    marquette Repository record for COMPARISON OF MANUFACTURED AND HAND-FORMED REVERSE CURVE OF SPEE NICKEL-TITANIUM WIRES (opens in a new tab)

  17. Efficacy of Occlusal Splint Appliance Fabrication Using Centric Relation Records: Polycentric Hinge vs. SAM-2 Articulators

    … appliances which require minimal time for chairside adjustment. With the relatively recent advent of arthroscopic surgery in conjunction with TMJ imaging, knowledge of the functioning TMJ continues to expand and articulator designs are beginning to replicate the functional TMJ anatomy. The …

    marquette Repository record for Efficacy of Occlusal Splint Appliance Fabrication Using Centric Relation Records: Polycentric Hinge vs. SAM-2 Articulators (opens in a new tab)

  18. IMPACT OF SINTERING PROTOCOL AND YTTERIA CONTENT ON THE INTERNAL AND MARGINAL ADAPTATION OF 3-UNIT MONOLITHIC ZIRCONIA FIXED DENTAL PROSTHESIS

    … reduced processing time, making it suitable for chairside workflows. However, HS, while time-efficient, introduces greater dimensional instability, necessitating further optimization. This study contributes to the growing body of knowledge in digital dentistry, offering valuable insights into …

    penn Repository record for IMPACT OF SINTERING PROTOCOL AND YTTERIA CONTENT ON THE INTERNAL AND MARGINAL ADAPTATION OF 3-UNIT MONOLITHIC ZIRCONIA FIXED DENTAL PROSTHESIS (opens in a new tab) Embargoed until 2027-03-17

  19. Fabrication and characterisation of biomimetic nacre-like ceramic/polymer composite a potential CAD/CAM dental material

    … infiltrated with polymer, as a potential chairside CAD/CAM dental material. <br/>Method. Bi-directional freeze-casting was used to fabricate highly aligned Al2O3 ceramic scaffolds. Different lamellar microstructures were created by controlling processing parameters such as cooling rate, …

    bristol Repository record for Fabrication and characterisation of biomimetic nacre-like ceramic/polymer composite a potential CAD/CAM dental material (opens in a new tab)

Page 1 of 3