Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 14 of 14 for “"Channelized Hotelling observer"”

  1. Model observers for predicting human performance on signal detection tasks.

    Various model observers have been applied to the objective assessment of medical image quality. However, the relevance of this application to clinical efficacy depends largely on how well model observers predict human performance. Attempting to answer this question, this dissertation focuses on the …

    arizona-thes Repository record for Model observers for predicting human performance on signal detection tasks. (opens in a new tab)

  2. Task-based lens design, with application to digital mammography

    Recent advances in model observers that predict human perceptual performance now make it possible to optimize medical imaging systems for human task performance. We illustrate the procedure by considering the design of a lens for use in an optically coupled digital mammography system. The …

    arizona-thes Repository record for Task-based lens design, with application to digital mammography (opens in a new tab)

  3. Visual-Search Model Observers in Assessing CT Acquisition Parameters

    … In a task-based image quality assessment, an observer such as a radiologist is to read an ensemble of images that are produced using different imaging systems or using the same system but with different parameters. An example of a task can be lesion detection. Then the performance of the …

    houston Repository record for Visual-Search Model Observers in Assessing CT Acquisition Parameters (opens in a new tab)

  4. Signal detection in lumpy backgrounds

    … we explore signal detection with model and human observers in the setting of nuclear medicine. Regarding the model observer, the main focus is on the linear observer that maximizes detectability, which we call the Hotelling observer. In particular, we outline two methods for realizing an estimate …

    arizona-thes Repository record for Signal detection in lumpy backgrounds (opens in a new tab)

  5. Signal detection with random backgrounds and random signals

    … methods to investigate Bayesian ideal observers for performing signal-detection tasks. Object models are used to take into account object variability in image backgrounds and signals for the detection tasks. In particular, lumpy backgrounds (LBs) and Gaussian signals are used for …

    arizona-thes Repository record for Signal detection with random backgrounds and random signals (opens in a new tab)

  6. List-mode SPECT reconstruction using empirical likelihood

    … model of the human visualsystem, the channelized Hotelling observer, is used tocompare the reconstructions by performing the Rayleigh task,a traditional measure of resolution. EM is found to producehigher resolution images than the histogram approach,suggesting that information is lost …

    arizona-thes Repository record for List-mode SPECT reconstruction using empirical likelihood (opens in a new tab)

  7. TASK SPECIFIC EVALUATION METHODOLOGY FOR CLINICAL FULL FIELD DIGITAL MAMMOGRAPHY

    … strategies and a variety of mathematical model observers in order to evaluate the performance of clinical FFDM systems under different conditions. To evaluate image acquisition performance, we tested a system-model-based Hotelling observer (SMHO) model on a bench-top system using a uniform …

    maryland Repository record for TASK SPECIFIC EVALUATION METHODOLOGY FOR CLINICAL FULL FIELD DIGITAL MAMMOGRAPHY (opens in a new tab)

  8. Task-Based Image Quality Assessment in X-Ray Computed Tomography

    … image quality measurements using model observers were used to evaluate the performance of X-Ray CT systems. To evaluate the dose reduction ability, detection tasks as well as combined detection and estimation tasks were considered. In detection tasks and combined detection and estimation …

    arizona-thes Repository record for Task-Based Image Quality Assessment in X-Ray Computed Tomography (opens in a new tab)

  9. Assessment of reconstructed images

    … images are used to obtain formulas for the observer SNRs for a variety of detection strategies, referred to as model observers. A number of psychophysical experiments have been conducted with the dual purpose of testing factors that influence human detection performance and providing a set …

    arizona-thes Repository record for Assessment of reconstructed images (opens in a new tab)

  10. An Investigation of Strategies for Applying Model Observers to Small Ensembles of Realistically Simulated Medical Images from Patient Populations Modeling Background and Signal Variations

    Model observers (e.g., the channelized Hotelling observer (CHO)) have been widely used in medical imaging to assess image quality. The CHO consists of the Hotelling observer applied to the outputs of a channel model. The CHO performance is affected by deviations of the input data (i.e., channel …

    jhu Repository record for An Investigation of Strategies for Applying Model Observers to Small Ensembles of Realistically Simulated Medical Images from Patient Populations Modeling Background and Signal Variations (opens in a new tab)

  11. Development and Application of Quantitative Metrics for Computed Tomography Image Quality Assessment

    … quantitatively evaluated the performance of the Channelized Hotelling Observer (CHO) and the exponential transformation of the free-response operating characteristic curve (EFROC) with respect to sensitivity to changes in dose. The number of images required to estimate the non-parametric EFROC …

    marquette Repository record for Development and Application of Quantitative Metrics for Computed Tomography Image Quality Assessment (opens in a new tab)

  12. RIGOROUS TASK-BASED OPTIMIZATION OF INSTRUMENTATION, ACQUISITION PARAMETERS AND RECONSTRUCTION METHODS FOR MYOCARDIAL PERFUSION SPECT

    … is evaluated based on the performance of an observer on diagnostic tasks relevant to MPS. In this work, we used three different model observers: the Ideal Observer (IO), and its extension, the Ideal Observer with Model Mismatch (IO-MM) and an anthropomorphic observer, the Channelized …

    jhu Repository record for RIGOROUS TASK-BASED OPTIMIZATION OF INSTRUMENTATION, ACQUISITION PARAMETERS AND RECONSTRUCTION METHODS FOR MYOCARDIAL PERFUSION SPECT (opens in a new tab)

  13. Model observer for optimizing digital breast tomosynthesis for detection of multifocal and multicentric breast cancer

    … they can be optimally interpreted by a trained observer, e.g., a radiologist. Start-of-art medical image quality is measured by the performance of an observer on a given clinical task. Since psychophysical studies are resource intensive, model observers are widely used as a surrogate in …

    texas Repository record for Model observer for optimizing digital breast tomosynthesis for detection of multifocal and multicentric breast cancer (opens in a new tab)

  14. Advanced Techniques for Image Quality Assessment of Modern X-ray Computed Tomography Systems

    … (e.g., detection of subtle lesions), (2) an “observer” to perform the task (e.g., a radiologists or a detection algorithm), and (3) a way to measure the observer’s performance in completing the task at hand (e.g., detection sensitivity/specificity).</p><p>First, this task-based image quality …

    duke Repository record for Advanced Techniques for Image Quality Assessment of Modern X-ray Computed Tomography Systems (opens in a new tab)