Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 129 for “"Charge Coupled Devices"”

  1. Spectroscopy of Charge-Coupled Devices

    A systematic study of persistent, or residual, images occurring in CCD imagers and a systematic study of dark current generation in CCD imagers are presented. These effects are a source of unwanted signal in frames, and should be considered where very exact, low light-level signal processing is …

    portland-state Repository record for Spectroscopy of Charge-Coupled Devices (opens in a new tab)

  2. Impact Ionization in Charge Coupled Devices

    A charge coupled device was designed and fabricated for the purpose of measuring impact ionization at the silicon-silicon dioxide interface. All past experiments have measured impact ionization either totally or partly in the bulk. Since the mobility of holes and electrons is lower at the interface …

    uiuc Repository record for Impact Ionization in Charge Coupled Devices (opens in a new tab)

  3. Charge-coupled devices in transmission electron microscopy

    … of experiments to test the suitability of charge-coupled devices (CCDs) for electron imaging. An electronic imaging system based on a CCD has several advantages over conventional imaging methods, particularly for image processing applications where quantitative data is required. The …

    glasgow Repository record for Charge-coupled devices in transmission electron microscopy (opens in a new tab)

  4. Radiation damage effects in charge coupled devices

    … radiation on the operation of EEV buried channel charge coupled devices (CCDs) have been studied. This work was instigated by the need to qualify CCDs for the SLD vertex detector. However, the work is also relevant to other small signal, low noise applications. The results of the batch …

    brunel Repository record for Radiation damage effects in charge coupled devices (opens in a new tab)

  5. Application of charge-coupled devices for astronomical spectroscopy

    It has been found, using a charge coupled device detector and a novel on chip pre-binning technique, that qualitative high dispersion spectroscopy is possible with a small telescope and poor seeing. Using the 30 inch Coude telescope at the Royal Greenwich Observatory, an atlas of an M3 giant, HR …

    durham Repository record for Application of charge-coupled devices for astronomical spectroscopy (opens in a new tab)

  6. A study of transversal filters using charge coupled devices

    concordia

  7. Charge-coupled devices for analog signal processing: recursive filter study.

    The objective of this thesis is to study the charged-coupled device signal processing in the area of discrete analog recursive filtering. Theoretical study of the first-order and the second-order discrete analog recursive filter, DAR, was carried out. Since the instrumentation was not adeguate for …

    nps Repository record for Charge-coupled devices for analog signal processing: recursive filter study. (opens in a new tab)

  8. Application of CCDs (Charge Coupled Devices) to Polarimetry and Spectropolarimetry

    Ideally, we would like to have at our disposal a "universal" instrument which could record all available information, i.e. the full Stokes vectors I, Q, U, V as function of spatial coordinates X and Y and wavelength A at given time t. The practical limitations of spectral dispersers now being used …

    glasgow Repository record for Application of CCDs (Charge Coupled Devices) to Polarimetry and Spectropolarimetry (opens in a new tab)

  9. Charge-coupled devices for analog signal processing : a circuit study

    The operation of a two-phase charge-coupled shift register is discussed and analyzed. A parametric study for simultaneous operation with more than one input signal is presented. The output circuit is analyzed for its contribution to nonlinearity. An analog signal processing linear model of the …

    nps Repository record for Charge-coupled devices for analog signal processing : a circuit study (opens in a new tab)

  10. Two-dimensional transient analysis of buried-channel charge-coupled devices

    <p>Since the invention of charge-coupled device (CCD) by W. S. Boyle and G. E. Smith in 1970, this device has drawn tremendous attention. CCD is considered as an important milestone in the electronic industry;In 1972, a new structure of CCD, called buried-channel charge-coupled device (BCCD) was …

    iastate Repository record for Two-dimensional transient analysis of buried-channel charge-coupled devices (opens in a new tab)

  11. Development of techniques to characterize electron-bombarded charge-coupled devices

    Electron Bombarded Charge Coupled Devices (EBCCDs) are a new hybrid image intensifier tube device that allows photoelectrons to be directly detected by a CCD placed as the tube anode. These devices have many significant advantages over traditional image intensified systems, due to their lower noise …

    arizona-thes Repository record for Development of techniques to characterize electron-bombarded charge-coupled devices (opens in a new tab)

  12. Search for Light Dark Matter with Damic-M Charge-Coupled Devices

    … to the search for light DM using silicon charge-coupled devices (CCDs) within the DAMIC-M (Dark Matter in CCDs-Modane) experiment. I first outline theoretical motivations and observational evidence supporting DM's existence. Subsequently, I describe the detection principles and operational …

    chicago Repository record for Search for Light Dark Matter with Damic-M Charge-Coupled Devices (opens in a new tab)

  13. An investigation into the use of charge-coupled devices for digital mammography

    … mammography system which uses phosphor coated charge-coupled devices (CCDs) for x-ray detection. The size mismatch between the breast and the CCD is overcome by operating the CCD in time delay and integration (TDI) mode and scanning across the breast. Multiparameter optimisations have been …

    ucl Repository record for An investigation into the use of charge-coupled devices for digital mammography (opens in a new tab)

  14. Long and short term effects of X-rays on charge coupled devices

    EEV buried channel charge coupled devices (BC CDs) with technological variations have been studied with respect to their response to 70kVp X-rays. Process variations considered are the conventional BCCD, scintillator coated BCCDs ( (Gadox(Eu) and Csl(Tl)) and the inversion mode device. The work was …

    brunel

Page 1 of 7