Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 20 for “"Charge Variants"”.
-
Development of New Separation Methods for Personalized Medicine
… concentration and compositions of glycoforms and variants under disease states. This dissertation described the development of various analytical separation-based methods to characterize various attributes of AGP for sample both in a purified form and in serum. The first and second chapters …
-
Development of a High-Throughput Analytical Platform for the Characterisation of Biopharmaceuticals Generated from Multi-Gene Engineered CHO Cells
… (CEX) methods enabled the profiling of size and charge variants with sub-2 g sensitivity. Online coupling of SEC with CEX in a two-dimensional liquid chromatography (2D-LC) set up with mass spectrometry (MS) detection (2D SEC-CEX-MS) combined aggregation analysis and charge variants peak …
-
Advances in and Applications of Capillary Scale Liquid Chromatography
… monoclonal antibodies including fragmentation, charge variants, and glycosylation profiles were able to be determined on the capillary scale. These results will help to make capillary-scale liquid chromatography a more viable solution for chromatographic analysis.
-
The 18.5-kDa Myelin Basic Protein has Loose Tertiary Contacts Regulated by Zinc and Post-Translational Modification
… that cause demyelination in animal models. The charge variants of MBP have been of particular interest. The C1 component, the least modified and most cationic of the variants, is the most abundant form of MBP in healthy adult myelin. The C8 component, the most modified and the least cationic …
-
The Impact of Dipeptides on Product Quality in Chinese Hamster Ovary Cells
… quality attributes (CQA) were assessed, i.e., charge variants and glycosylation. It was determined that the dipeptide additions increased operational simplicity, without negative CQA or cell growth.
-
STRUCTURAL IMPLICATIONS OF GLUCOSE AND COPPER AVAILABILITY ON GLYCATION PROCESSES IN CHINESE HAMSTER OVARIAN (CHO) CELL-DERIVED PROTEINS
… induce conformational changes and alter the net charge of the resulting proteins, making it essential to identify charge variants as a regulatory requirement in bioprocessing. Here, the changes in charge variance from different media formulations and additives were analyzed using a proprietary …
-
Protector Peptides for Mitigating Oxidative Stress and Improving Product Quality Attributes in CHO Cell Biomanufacturing
… viable cell density, specific productivity, and charge variant profile within an intermediate concentration range, while higher concentrations were cytotoxic; its methylated analog did not replicate these benefits, consistent with differences in enzymatic susceptibility between the two …
-
Formulation Parameters Assessment and Molecule Impact Evaluation on the Use of 5% Dextrose (D5W) as Alternative Diluent for Intravenous Infusion of Therapeutic Monoclonal Antibodies (mAbs)
… more chemical stability changes including acidic charge variants and total glycation formation, while ionic strength and buffer system type do not play significant roles in either physical or chemical in use stability for mAbs 1-4. In the in-vitro human plasma studies, both increasing pH and ionic …
-
Characterization of the heat shock proteins in cultured trout cells Mach II
… analysis separated into several isoelectric variants following two-dimensional gel electrophoresis. Post-translational modification of a single polypeptide could have given rise to charge variants similar to those observed here, but no evidence for either the phosphorylation of the hsps or …
-
Accelerating Mammalian Cell Biomanufacturing: From Concentrated Media Feed to CHO Product Quality
… speed on CHO cell culture profiles and antibody charge variant distribution, choosing National Institute of Standards and Technology Chinese Hamster Ovary (NISTCHO) cells as case study. Cell growth and viability were monitored throughout culture, and purified antibody samples were analyzed for …
-
Dynamic pH junction focusing and isoelectric focusing in capillary electrophoresis mass spectrometry
… interface is an attractive method for the charge heterogeneity characterization of biopolymers. Peptide and protein were used to demonstrate the feasibility of two online electrolyte configurations. pI resolution up to 0.02 pH in neutrally-coated capillaries demonstrated the high separation …
-
Exploring Modalities of Productivity and Critical Quality Attributes in Fed-batch Chinese Hamster Ovary Cell Cultures
… quality attributes such as glycosylation and charge variants for a CHO-K1 cell line. The glutamate-driven feeding strategy was used to diminish the negative effects of overfeeding that often occur with a typical daily bolus feeding strategy. The results indicated that amino acid driven feeding …
-
Multidimensional Chromatographic Coupling Strategies Implementing Capillary-Channeled Polymer Fiber Stationary Phases
… exchange chromatography (WCX) is used for the charge variant characterization, which is used to reveal information about the efficacy of the therapeutic end product. Another sought-after therapeutic for vectors is exosomes. Exosomes, or small EVs (sEVs), are excreted from cells, made up of a …
-
Quantification and simulation of liquid chromatography-mass spectrometry data
… on toxic compounds. Decharging infers the uncharged mass of a peptide (or protein) by clustering all its charge variants. The latter occur frequently under certain experimental conditions. We employ simulation to show that decharging is robust against missing values even for high complexity …
-
Photodegradation of peptides and proteins by near UV and visible light
… to aggregation, fragmentation, the formation of charge variants, and oxidation products in pharmaceutical proteins and peptides. The nature and yields of the oxidation products depended on the concentration of Fe3+ present in the solution, the concentration of buffer, and the excipients added.
-
Advancing capillary electrophoresis-mass spectrometry for top-down proteomics : technical development and biological applications
… accurate isoelectric point (pI) determination of charge variants (~0.1 pI difference) of monoclonal antibodies (mAbs). In Chapter 4, we developed a nondenaturing cIEF-MS platform for ultrahigh resolution characterization of microheterogeneity of a variety of protein complexes. Typically, pI …
-
Development of ultrafast protein digestion and standards free quantitation methods for mass spectrometric analysis
… the ultrafast middle-down digestion of antibody charge variants following separation by strong cation exchange (SCX) chromatography. This approach utilizes the enzymes IdeS and EndoS2 in conjunction with tris(2-carboxyethyl)phosphine (TCEP) to rapidly generate antibody subunits for detailed …
-
Biophysical Characterization and Bioprocessing of Proteins
… it was possible to identify monoclonal antibody charge variants. While the obtained resolution was comparable to that of column chromatography, membrane chromatography provided faster processing overall. The work documented in this thesis provides a “proof-of-concept” methodology as an …
-
High-Efficiency Membrane Chromatography Devices for Downstream Purification of Biopharmaceuticals: Design, Development, and Applications
… showed great performance in separation of mAb charge variants when extensively shallow gradients (60 membrane bed volumes) were required. The devices offered very stable conductivity gradients at high flow rates. LFMC devices in three different preparative scales gave great performance in …
-
Tailoring Recombinant Protein Quality by Rational Media Design
… fucosylation, galactosylation and sialylation), charge variants, aggregates and low-molecular-weight species formation, is pivotal for efficient receptor binding and for triggering the desired immune responses in patients. In the frame of biosimilar development, product quality modulation methods …