Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 27 for “"Charge-state distribution"”

  1. Measurement and Modeling of Temperature and Charge State Distribution in Laboratory Photoionized Plasmas

    … lack of a detailed treatment of excited state populations, are responsible for the remaining overestimation in the temperature of the time-dependent model relative to experiment. The ionizations across the suite of steady state and time-dependent models developed in Cloudy, Cretin, and …

    unr Repository record for Measurement and Modeling of Temperature and Charge State Distribution in Laboratory Photoionized Plasmas (opens in a new tab)

  2. Developments for a measurement of the beta-nu correlation and determination of the recoil charge state distribution in 6He beta decay

    … the high-precision a_{beta-nu} measurement. The charge state distribution of recoil ions is obtained by analyzing their time-of-flight distribution using the same experimental setups for the a_{beta-nu} measurement. An analysis approach that is independent of the beta-nu correlation is developed. …

    washington Repository record for Developments for a measurement of the beta-nu correlation and determination of the recoil charge state distribution in 6He beta decay (opens in a new tab)

  3. Time-Resolved ExB Probe Measurement of Hall Thruster Plasma

    … on Fourier transfer functions between the discharge current and ExB probe measurements. The research serves as the baseline for future investigation of time-resolved ion velocity and charge state diagnostics for Hall-effect thrusters. ExB measurement is closely tied to both the ion velocity …

    washington Repository record for Time-Resolved ExB Probe Measurement of Hall Thruster Plasma (opens in a new tab)

  4. Observation and Characterization of Trends in the Ionization of the Warm Absorber Photoionized Plasma Experiment at Z

    … of the experimental data yields ion fractions, charge state distribution, and electron temperature of the photoionized plasma. The measurements show trends in ionization and charge state distribution with changes to the experimental parameters, revealing the net result of the competition between …

    unr Repository record for Observation and Characterization of Trends in the Ionization of the Warm Absorber Photoionized Plasma Experiment at Z (opens in a new tab)

  5. A study of protein interactions by electrospray ionization mass spectrometry.

    … biological systems. It is able to form multiply charged ions, which facilitates analyses of very large molecules. The change of the protein conformations can be investigated by charge state distribution shifts in ESI-MS. The noncovalent interactions of proteins with other molecules can also be …

    wvu Repository record for A study of protein interactions by electrospray ionization mass spectrometry. (opens in a new tab)

  6. Advances in the design, modelling and operation of high-performance Electron Beam Ion Sources

    Highly charged ions see widespread use in fundamental research, medicine, and industry. This thesis describes development work carried out to improve on the charge breeding performance of electron beam ion sources (EBIS) and to advance their modelling in computer simulations. Established …

    heid-diss Repository record for Advances in the design, modelling and operation of high-performance Electron Beam Ion Sources (opens in a new tab)

  7. Multiple coincidence experiments in fast ion-atom collisions

    … have coincidentally measured the projectile ion charge state and the target recoil ion charge state after the collision, and the energy of a free electron emerging from the same collision with a velocity close to the beam velocity, for 1 MeV/u bare and one electron oxygen and carbon projectiles …

    ut-knoxville Repository record for Multiple coincidence experiments in fast ion-atom collisions (opens in a new tab)

  8. Low Current Electrospray Ionization Mass Spectrometry for Environmental Contaminants and Proteins

    … The second part of the study focused on the charge state distribution of model protein ions in femtoampere ESI under different pH conditions. The study found that signal intensities of proteins were 4 orders of magnitude lower in femtoampere mode than the nanoampere mode, and the average …

    unh-thes Repository record for Low Current Electrospray Ionization Mass Spectrometry for Environmental Contaminants and Proteins (opens in a new tab)

  9. Mass Spectrometry and Tandem Mass Spectrometry Analysis of Polymers and Polymer-Protein Interactions

    … transfer dissociation (ETD) behavior of doubly charged ions with two different types of charges. Both CAD and ETD were used for the structural analysis of a protonated-sodiated peptide and sodiated-ammoniated polysaccharides. The advantages of ETD over CAD were documented with ETD spectra that …

    ohiolink Repository record for Mass Spectrometry and Tandem Mass Spectrometry Analysis of Polymers and Polymer-Protein Interactions (opens in a new tab)

  10. Plasma evolution and continuum lowering in hot dense matter generated by X-ray free electron lasers

    … <p>The code is first validated, by modelling the charge state distribution measured in a previous experiment (L. Young <em>et. al</em>), where the LCLS interacts with a Ne gas, a simplified (collisionless) problem. Then it is used to model the K-alpha spectroscopic data obtained for Al. The plasma …

    oxford Repository record for Plasma evolution and continuum lowering in hot dense matter generated by X-ray free electron lasers (opens in a new tab)

  11. Measurements of the cusp electron peak in coincidence with target recoil ions and in coincidence with LMM Auger electrons produced in ionizing collisions for the 3 MeV Cℓ + Ar collision system

    … - spectrometer can also detect recoil ions. A charge state analyzer located after the detector allows for the exit charge state to be determined. The new detector has been tested through multiple tests and a computer simulation program. Projectile electron loss to the continuum in atomic …

    ut-knoxville Repository record for Measurements of the cusp electron peak in coincidence with target recoil ions and in coincidence with LMM Auger electrons produced in ionizing collisions for the 3 MeV Cℓ + Ar collision system (opens in a new tab)

  12. Proton capture on ³⁴S in the astrophysical energy regime

    … of several years of accumulated energy loss and charge state distribution data was done to provide a realistic means of access for this information and to update a semi-empirical formula for predicting the charge state distributions of ions passing through gas.

    colo-mines Repository record for Proton capture on ³⁴S in the astrophysical energy regime (opens in a new tab)

  13. A Numerical Model of Atomic Relaxation and its Applications

    … Dirac-Fock method for any specified distribution of atomic vacancies. This CPU-intensive computational approach is adopted to account for the effect of spectator vacancies resulting from non-radiative transitions that occur during the atomic relaxation. The shake theory from Carlson …

    anu Repository record for A Numerical Model of Atomic Relaxation and its Applications (opens in a new tab)

  14. DEVELOPMENT AND CHARACTERIZATION OF ELECTROSPRAY IONIZATION MODES IN MASS SPECTROMETRY: APPLICATIONS IN PROTEIN ANALYSIS AND BEYOND

    … that correlates with the size of initial charged droplets generated. Smaller initial charged droplets have exhibited improved performances, including enhanced ionization efficiency, reduced nonspecific adducts, and minimized sample consumption. It would be of significant interest to …

    unh-thes Repository record for DEVELOPMENT AND CHARACTERIZATION OF ELECTROSPRAY IONIZATION MODES IN MASS SPECTROMETRY: APPLICATIONS IN PROTEIN ANALYSIS AND BEYOND (opens in a new tab)

  15. Modeling the heating and atomic kinetics of a photoionized neon plasma experiment

    … atomic kinetics model to simulate the electron distribution function and configuration-averaged atomic kinetics, (3) a radiation-hydrodynamics code with inline non-equilibrium atomic kinetics to perform a comprehensive numerical simulation of the experiment and plasma heating, and (4) …

    unr Repository record for Modeling the heating and atomic kinetics of a photoionized neon plasma experiment (opens in a new tab)

  16. Quantitative Analysis of Multiple Charged Large Molecules in Human or Rat Plasma Using Liquid Chromatography Tandem Mass Spectrometry

    … A polypeptide can exist in multiple charge states separated by mass to charge ratio (m/z). Herein, the charge state distribution and the formation of product ions to form selected reaction monitoring (SRM) transitions for intact polypeptide quantitative analysis was evaluated in …

    vcu Repository record for Quantitative Analysis of Multiple Charged Large Molecules in Human or Rat Plasma Using Liquid Chromatography Tandem Mass Spectrometry (opens in a new tab)

  17. Dual-spray Synthesis and Reactions

    … electrospray emitter. Clear shifts in isotope distributions indicated hydrogen-deuterium exchange occurring within the ion source. By ion mobility, simultaneous deuterium exchange for two isobaric species, the oxytocin monomer and dimer, was observed. Lysozyme has a linear relation between the …

    ottawa-retro Repository record for Dual-spray Synthesis and Reactions (opens in a new tab)

  18. Molecular response to ultra-intense x-rays studied with ion and electron momentum imaging

    … including sequential photoionization, ultrafast charge rearrangement and molecular fragmentation are studied. And it is observed that because of the charge rearrangement, molecules exposed to ultra-intense x-rays can be ionized more heavily than the isolated atoms with similar photoabsorption …

    ksu Repository record for Molecular response to ultra-intense x-rays studied with ion and electron momentum imaging (opens in a new tab)

  19. Investigation of Protein-Ligand Complexes by Native Mass Spectrometry and Ion Mobility-Mass Spectrometry

    … structure. By measuring the mass-to-charge ratio of the ionic species, information on mass, charge, and stoichiometry can be obtained. Native MS is readily compatible with other gas- phase techniques, such as ion mobility spectrometry (IMS) and the combination of both methods, …

    fu-berlin Repository record for Investigation of Protein-Ligand Complexes by Native Mass Spectrometry and Ion Mobility-Mass Spectrometry (opens in a new tab)

  20. Electrospray ionization mass spectrometry for the analysis of proteins and small molecules

    … the influence of instrumental parameters on the Charge State Distribution (CSD) of the heme proteins cytochrome c and myoglobin, and discusses a method for monitoring conformational changes of proteins by calculating an Average Observed Charge (AOC) for a given spectrum.;Chapter 4 is also devoted …

    wvu Repository record for Electrospray ionization mass spectrometry for the analysis of proteins and small molecules (opens in a new tab)

Page 1 of 2