Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 12 of 12 for “"Charged particle detection"”
-
A binary encoded strip scintillation hodoscope for charged particle detection
… the counters in high energy or highly ionizing particle experiments are expected.
-
An Investigation of the possibility of charged particle detection using tunneling between superconductors
… the feasibility of developing a nuclear particle detector utilizing tunneling between superconductors. For optimum detector performance, temperatures lower than 1.2°K are mandatory. Accordingly, a He⁴ cryostat capable of being modified to a He³ cryostat has been constructed and tested. …
-
Development of charged particle detection systems for materials analysis with rapid ion beams : large solid angle detectors and numerical nuclear pulse processing
Cette thèse présente de nouveaux développements en détection de particules chargées et traitement tout-numérique d'impulsions pour application à l'analyse avec des faisceaux d'ions rapides (IBA). Un ensemble de 16 détecteurs gravés sur une puce de Si est mis en œuvre, ce qui fournit un angle solide …
-
Fabrication of Silicon-based Planar Structural Charged Particle Detector
Charged particle detectors are widely used in nuclear physics, astrophysics and environmental monitoring areas. The applications include charged particle spectroscopy, air monitoring, alpha beta counting, etc. This thesis outlines the basics of charged particle detection and spectroscopy. Then the …
-
Measuring neutrons in heavy ion collisions
… Nuclear Equation of State (EOS), neutrons and charged-particles were measured with beams of 40,48Ca at 56,140 MeV/u on targets of 58,64Ni and 112,124Sn. The updated High Resolution Array (HiRA10) was used for charged-particle detection. A charged-particle veto wall was designed and constructed …
-
Characterization and evaluation of the microcantilever radiation detector
<p>In this study, a microcantilever charged-particle detector was characterized and evaluated. The method employed involved sensing an electric field emanating from a small collector plate on which charge built up to charged-particle flux.Sensitivity to alpha particles was determined using …
-
Development of Front-End Protection Circuit for TeBAT Nuclear Physics Research
… adaptive gain, and enable higher-resolution charged particle detection. In doing so, it strengthens the operational robustness of the TeBAT system and contributes to advancing experimental capabilities in nuclear and particle physics research.
-
Development of Front-End Protection Circuit for TeBAT Nuclear Physics Research
… adaptive gain, and enable higher-resolution charged particle detection. In doing so, it strengthens the operational robustness of the TeBAT system and contributes to advancing experimental capabilities in nuclear and particle physics research.
-
Homodyne High-harmonic Spectroscopy: Coherent Imaging of a Unimolecular Chemical Reaction
… photoelectron spectroscopy, based on charged particle detection, to a fully coherent one, based on light characterization. The main achievement presented in this thesis is to use high harmonic generation to probe femtosecond (femto=10^-15) chemical dynamics for the first time. Thanks …
-
Beta-decay total absorption spectroscopy around A = 100-110 relevant to nuclear structure and the astrophysical R process
… Cyclotron Laboratory and combined charged-particle detection using silicon detectors and $\gamma$-ray detection using a segmented total absorption spectrometer called the Summing NaI(Tl) (SuN) detector.The commissioning experiment with a thermalized beam examined the $\beta$ decay …
-
Pixellated radiation detectors for scientific applications
… The first one - HEPAPS4 - designed for charged particle detection, with the potential technology application in the vertex detector for the International Linear Collider. The noise of the sensor was measured to be 35±5 e, which agrees well with simulated data. The dark current was found …
-
Rotational bands representing a multiplicity of shapes in ¹²⁷⁻¹³¹Pr
… array was used in conjunction with the Microball charged particle detection system. Highly correlated γ-ray and charged particle events were recorded to tape. In subse-quent offline analysis, which is the subject of this dissertation, the (3<em>p</em>, <em>xn</em>) channel yielded high spin …