Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 46 for “"Chelex-100"”.

  1. Speciation and determination of trace lead : methodology development and analysis of natural waters using Chelex-100 and GFAAS

    … of lead was successfully conducted using Chelex-100 and graphite furnace atomic absorption spectroscopy (GFAAS). Sorption under static conditions and direct measurements in the bead slurry or after fast elution of lead from beads with HNO3 solution was used. The effects of buffers, …

    njit Repository record for Speciation and determination of trace lead : methodology development and analysis of natural waters using Chelex-100 and GFAAS (opens in a new tab)

  2. Evaluation of Chelex 100 and Assessing the Impact of Fulvic Acid (NOM) on Copper Toxicity and Bioavailability to Americamysis bahia

    A cation exchange method (Chelex 100) that distinguishes weakly bound and strongly bound copper was investigated for its ability to measure bioavailable copper in estuarine waters. Copper bound to the Chelex 100 resin was operationally defined as bioavailable copper. Varying initial copper …

    vt Repository record for Evaluation of Chelex 100 and Assessing the Impact of Fulvic Acid (NOM) on Copper Toxicity and Bioavailability to Americamysis bahia (opens in a new tab)

  3. Développement des sondes DGT spécifiques à l'échantillonnage in situ du radium à base des gels récepteurs de TK100, d'AG50W-X8, de CHELEX-100 et des oxydes de manganèse

    ...Si un enrichissement des teneurs en radium dans les échantillons environnementaux (sols, sédiments, eau, biote...) témoigne de la contamination d'un écosystème, les informations concernant sa mobilité, sa réactivité et sa biodisponibilité demeurent fragmentaires. C'est dans ce contexte que …

    moncton Repository record for Développement des sondes DGT spécifiques à l'échantillonnage in situ du radium à base des gels récepteurs de TK100, d'AG50W-X8, de CHELEX-100 et des oxydes de manganèse (opens in a new tab)

  4. Trace Metal and Speciation Analysis using Ion-Exchange and Energy Dispersive X-ray Fluorescence Spectrometry

    … (Dowex 50W-X8 and Dowex 1-X8) and chelation (Chelex-100) resins, in order to determine their physical and chemical characteristics, to understand and explain their limits of function and to optimise their use as substrates in trace metal and speciation measurement by EDXRF. Structural …

    plymouth Repository record for Trace Metal and Speciation Analysis using Ion-Exchange and Energy Dispersive X-ray Fluorescence Spectrometry (opens in a new tab)

  5. Biodisponibilidade de metais pesados em solos do Rio Grande do Sul

    … mol L¹", HNO3- HClO4, concentrados, resina CHELEX 100 e por um bioteste com plantas de aveia (Avena sativa, L.). As análises de regressão indicaram que a solução DTPA apresentou coeficientes de determinação estatisticamente significativos e iguais ou maiores que 0,60 para Cd e Zn, nas duas …

    brazil-ufrgs Repository record for Biodisponibilidade de metais pesados em solos do Rio Grande do Sul (opens in a new tab)

  6. Nové sorpční gely pro užití v technice difúzních gradientů v tenkých filmech

    … navázaném v tenké vrstvě hydrogelu. Iontoměnič Chelex 100, který se v technice DGT běžně používá, je vysoce selektivní pro volné ionty kovů nebo jejich labilní ionty v roztoku. Tato diplomová práce se zabývá charakterizací nového sorpčního gelu na bázi iontoměniče s thiolovými funkčními …

    brno-tech Repository record for Nové sorpční gely pro užití v technice difúzních gradientů v tenkých filmech (opens in a new tab)

  7. Vývoj techniky difúzního gradientu v tenkém filmu (DGT) pro stanoveni rtuti ve vodných systémech.

    … rtuti technikou DGT a to Duolite GT-73, Chelex-100, Spheron-Thiol. Tato práce rozšiřuje škálu těchto sorbentů o nově připravené sorpční gely, a to Iontosorb AV modifikovaný imidazolem nebo 6-merkaptopurinem a komerčně dostupnou látku oxid titaničitý. Je popsán způsob přípravy sorpčních …

    brno-tech Repository record for Vývoj techniky difúzního gradientu v tenkém filmu (DGT) pro stanoveni rtuti ve vodných systémech. (opens in a new tab)

  8. Preconcentration of Trace Metal Ions from Natural Waters: Studies on the Application of an Acrylic Ester Macroreticular Resin

    … and less susceptible to contamination than the Chelex-100 method. In addition, a larger preconcentration factor was obtained. The accuracy and precision of the XAD-7 method were found to be at least competitive with the Chelex-100 method.</p> <p>The mechanism of adsorption was investigated and …

    mcmaster Repository record for Preconcentration of Trace Metal Ions from Natural Waters: Studies on the Application of an Acrylic Ester Macroreticular Resin (opens in a new tab)

  9. Studium vlastností sorpčních gelů pro stanovení rtuti technikou DGT.

    … tyto sorbenty: Duolit GT-73, Spheron-Thiol, Chelex-100 a nově modifikovaný sorbent Iontosorb AV. Nejprve byla optimalizována příprava všech sorpčních gelů. Po optimalizaci přípravy byly sorpční gely testovány v modelových roztocích rtuti. Byl proveden test návratnosti a test závislosti …

    brno-tech Repository record for Studium vlastností sorpčních gelů pro stanovení rtuti technikou DGT. (opens in a new tab)

  10. A Method for the Determination of Non-ceruloplasmin-bound Copper in Blood Serum and Some of Its Applications

    … was firstly isolated from the serum by using Chelex 100 resin. Both the non-ceruloplasmin-bound copper and the total copper were determined by neturon activation analysis, atomic absorption spectroscopy and a spectrophotometric method using zinc dibenzyldithiocarbamate as the chelating agent. …

    mcmaster Repository record for A Method for the Determination of Non-ceruloplasmin-bound Copper in Blood Serum and Some of Its Applications (opens in a new tab)

  11. Stanovení mikroprvků v mléce pomocí ICP-OES po extrakci technikou DGT

    … za použití sorpčního gelu obsahujícího sorbent Chelex 100 a agarózového difúzního gelu. Optimalizace techniky DGT v modelových roztocích kovů proběhla pomocí doporučovaných základnách testů. Poté byla ověřena výkonnost techniky DGT v matrici zředěného mléka. Při analýze reálného vzorku mléka byl …

    brno-tech Repository record for Stanovení mikroprvků v mléce pomocí ICP-OES po extrakci technikou DGT (opens in a new tab)

  12. In vivo metal substitution in bacteroides superoxide dismutase

    … was decreased by treatment of the media with chelex-100, a metal-chelating resin, and addition of desferrioxamine mesylate (desferal, Ciba-Geigy), an iron chelator. Mn-containing (MnSOD) and Fe-containing superoxide dismutase (EeSOD) activities in cell extracts were differentiated by …

    vt Repository record for In vivo metal substitution in bacteroides superoxide dismutase (opens in a new tab)

  13. LITERATURE REVIEW: The Use of Cation-Exchange Resins in Natural Water Trace Metals Research. ARTICLE: Determination of Free Ion Trace Metal Concentrations in Freshwaters Using Cation-Exchange Resin Equilibrium. A Preliminary Investigation.

    … Use of cation exchange resins, particularly Chelex-100, has been developed over the past few decades and enables preconcentration to yield, upon elution, measurable concentrations of trace metals. These resins can also yield data on the speciation (by measuring lability) of a metal in …

    lancaster Download PDF for LITERATURE REVIEW: The Use of Cation-Exchange Resins in Natural Water Trace Metals Research. ARTICLE: Determination of Free Ion Trace Metal Concentrations in Freshwaters Using Cation-Exchange Resin Equilibrium. A Preliminary Investigation. (opens in a new tab)

  14. Investigation of the Effects of Environmental Insults on Presumptive and Confirmatory Tests and DNA Degradation

    … method could be used. The methods used were: Chelex-100, Phenol/chlorophorm, QIAamp® DNA Investigator Kit (Qiagen), InnuPREP® forensic extraction kit (Analytikjina), the EZ1® system using the investigator card (Qiagen), the AutoMate Express™ System using the PrepFiler™ Express kit (Applied …

    cent-lancashire Download PDF for Investigation of the Effects of Environmental Insults on Presumptive and Confirmatory Tests and DNA Degradation (opens in a new tab)

  15. Preconcentration of Trace Metal Ions from Natural Waters: Complexation with Meso-Tetra (p-sulfonatophenyl) porphine and Adsorption onto XAD Resins

    … a precision comparable to that of the accepted Chelex-100 method. Application of the method to natural seawater samples failed, largely because of aggregation in the highly saline medium. </p> <P> Adsorption isotherms of TPPS4 and its complexes on XAD resins were obtained. Adsorption onto XAD-2 …

    mcmaster Repository record for Preconcentration of Trace Metal Ions from Natural Waters: Complexation with Meso-Tetra (p-sulfonatophenyl) porphine and Adsorption onto XAD Resins (opens in a new tab)

  16. Lietuvos populiacijos 27 Y-STR lokusų įvertinimas teismo genetikos kontekste /

    … Genomic DNA profiles were extracted using Chelex - 100 resin; genotyped according to the 27 microsatellite region and amplified each DNA area using PCR. Then separating the reaction products by capillary electrophoresis using computer equipment, statistical approaches and computational …

    vilnius Repository record for Lietuvos populiacijos 27 Y-STR lokusų įvertinimas teismo genetikos kontekste / (opens in a new tab)

  17. DNA-analytische Speziesdiagnostik

    … aus Spurenmaterial getestet. Die Kombination aus Chelex-100-Extraktion und DNA-Aufreinigung mittels Diatomeen erwies sich als besonders geeignet. Neben dem Hervorbringen einer ausreichend großen Menge an DNA-Material besticht diese Methodik durch einen sehr geringen Zeit- und Kostenaufwand, …

    wurz-thes Repository record for DNA-analytische Speziesdiagnostik (opens in a new tab)

  18. Trace element contaminants in the Kuwait water production system

    … in the analysis. Solid-liquid extraction (chelex-100 resin) and liquid-liquid extraction (methyl iso-butyl ketone and freon) with and without back-extraction into nitric acid were investigated. Liquid-liquid extraction without back-extraction proved to give optimum recovery of the selected …

    brunel Repository record for Trace element contaminants in the Kuwait water production system (opens in a new tab)

Page 1 of 3