Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 197 for “"Chemical Ionization"”.
-
Chemical Ionization Pyrolysis Mass Spectrometry of Humic Materials
Pyrolysis mass spectrometry (PYMS) was use to characterize humic acids and fulvic acids in positive-ion and negative-ion acquisitions. A suite of several reference humc acids and fulvic acids, representing a variety of environments, were fast-pyrolyzed in the presence of several reagent gases. …
-
Negative ion chemical ionization GCMS analysis of valproic acid and its metabolites
… of VPA and its metabolites by negative ion chemical ionization (NICI) GCMS was evaluated for the desired sensitivity and specificity. An assay was thus developed for VPA in serum and saliva based on NICI-GCMS of the pentafluorobenzyl (PFB) derivative. The NICI spectrum of the PFB ester of …
-
Using chemical ionization mass spectrometry to probe indoor and outdoor atmospheric chemistry
… analytes using a fast (1 Hz), online chemical ionization mass spectrometry (CIMS) measurement technique utilizing iodide reagent ions. Combining these and other measurements of gas-phase analytes and particulate matter present in indoor air during HOMEChem enables us to piece together …
-
Metal ion chemical ionization - the gas phase chemistry of cobalt containing ions
Thesis (Ph. D.)--Michigan State University. Department of Chemistry, 1984
-
Analysis of polycyclic aromatic hydrocarbons by chemical ionization and ion trap mass spectrometry
… The first objective was achieved by using chemical ionization (CI) mass spectrometric techniques. Negative CI with CO₂ and N₂O as reagent gases resulted in the formation of isomer specific adducts, such as [M + G – H]⁻, between PAH molecules (M) and gas phase negative ions (G), enabling the …
-
Measurements of current-use pesticides and oxidation products using chemical ionization mass spectrometry
… a variety of plant species and also synthetic chemicals that are used to protect vulnerable organisms against disease carriers, harmful pests, and intrusive or undesirable vegetation. Pesticide use has large agricultural, economic, and health benefits which include increased staple food …
-
Measurement of pernitric acid and inorganic bromine species using chemical ionization mass spectrometry
… It allows scientists to explore the atmosphere. Chemical ionization mass spectrometry (CIMS) has been utilized to measure atmospheric trace gases. This thesis presents two projects that involve CIMS measurements: measurements of pernitric acid (HO2NO2) in metropolitan Atlanta in winter 2014 and …
-
Application of Atmospheric Pressure Chemical Ionization Gas Chromatography in Urine Organic Acid Analysis
… LC-ESI (liquid chromatography-electrospray Ionization) and GC-APCI (Atmospheric Pressure Chemical Ionization) instrument set-up, while maintaining accuracy and sensitivity in both LC and GC applications. Utilizing this novel GC-APCI instrument, this project aims to develop and validate a new …
-
Development of a chemical ionization mass spectrometry technique for the direct measurement of HO₂
… may be explained by uncharacterized chemical pathways or deficiencies in current measurement techniques, likely attributable to the indirect nature of such techniques. A direct method for measuring HO₂ would aid in accurately constraining HO₂ chemistry in the atmosphere. In this work, …
-
Mass spectrometric studies of molecules modified for analysis by electron capture negative chemical ionization
Thesis (Ph. D.)--Michigan State University. Department of Chemistry, 1985
-
Use of chemical ionization mass spectrometry for study of photochemical properties: ketone photolysis quantum yields
… This dissertation demonstrates the utility of chemical ionization mass spectrometry for measurements of radical quantum yields in the photolysis of organic trace gases in the laboratory setting. Chapter 2 addresses the development of a coupled chemical ionization mass spectrometer with iodide …
-
Fundamentals of ambient metastable-induced chemical ionization mass spectrometry and atmospheric pressure ion mobility spectrometry
Molecular ionization is owed much of its development from the early implementation of electron ionization (EI). Although dramatically increasing the library of compounds discovered, an inherent problem with EI was the low abundance of molecular ions detected due to high fragmentation leading to the …
-
Development, Evaluation, and Application of a Gas Chromatography – Atmospheric Pressure Chemical Ionization Interface for Orbitrap Mass Spectrometers
… fields including forensics, medicine, and petrochemicals. Until recently, many GC-MS instruments have relied on either electron ionization or chemical ionization sources with low resolution mass analyzers. With improving technology, Thermo Fisher Scientific launched the Q Exactive™ GC hybrid …
-
Chemical Ionization Mass Spectrometry Study of Sulfuric Acid and Amine Chemical Nucleation Processes Pertinent to the Atmosphere
… is (1) to better understand the technique of chemical ionization mass spectrometry (CIMS) for measuring SA and its clusters and (2) to measure and model how various atmospherically relevant basic gases, such as ammonia and amines, affect SA nucleation. The main instrument, the Cluster CIMS, …
-
Applications of Soft Chemical Ionization Mass Spectrometry: Taking the next steps along the journey of breath analysis
Contains fulltext : 289476.pdf (Publisher’s version ) (Open Access)
-
Mass spectrometric investigation of the OH induced oxidation of isoprene using 0 2 + as a chemical ionization reagent
… chamber contained a quadrupole ion-trap where chemical ionization and ion storage took place. 02 + ions were used as chemical ionization reagent. Sample fragments were stored in the center of the ion-trap where their trajectories were stable, then after a certain period of storage time ejected …
-
Development and Applications of Capillary Vibrating Sharp-Edge Spray Ionization Coupled with Atmospheric Pressure Chemical Ionization (cVSSI-APCI)
… However, ion sources, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) can encounter problems such as ion suppression and an inability to ionize based on size and/or polarity, respectively. Further these sources are bulky and require gas flow, heat …
-
Direct, quantitative analysis of organic contaminants in complex samples using membrane introduction mass spectrometry with electron and chemical ionization
… a system coupling CP-MIMS to electrospray ionization (ESI), the use of a PIM for model compounds resulted in faster response (~3×) and improved sensitivity (~3.5×, parts per trillion level detection limits). While effective for the demonstration of the PIM, pairing ESI with CP-MIMS …
Page 1 of 10